Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 32 for “"Detective quantum efficiency"”.

  1. Modeling of the frequency dependent detective quantum efficiency of X-ray imaging detectors

    … measure is the frequency, f , dependent detective quantum efficiency, DQE(f ). In this thesis, we have proposed a parallel cascaded linear system model for calculating DQE(f ) by considering the effects of K-fluorescence reabsorption, the range of primary photo electrons, charge carrier …

    concordia Download PDF for Modeling of the frequency dependent detective quantum efficiency of X-ray imaging detectors (opens in a new tab)

  2. TOWARD A MORE CLARIFIED DETECTIVE QUANTUM EFFICIENCY METHODOLOGY: STUDY OF THE DQE THEORY AND APPLICATIONS

    Detective quantum efficiency (DQE) is widely accepted as the golden rule to objectively evaluate the performance of x-ray imaging systems. It provides a comprehensive characterization of an x-ray imaging system, because it combines several important image-quality-related measurements such as …

    oklahoma-thes Repository record for TOWARD A MORE CLARIFIED DETECTIVE QUANTUM EFFICIENCY METHODOLOGY: STUDY OF THE DQE THEORY AND APPLICATIONS (opens in a new tab)

  3. Evaluation of digital x-ray imaging technologies for tuberculosis screening

    … transfer function, noise power spectrum, and detective quantum efficiency. The system designs and the results of the experiments are shown. Details are also shown about the setup of the x-ray lab, including the door interlock system for a lead-lined x-ray cabinet. To determine whether a …

    waterloo Repository record for Evaluation of digital x-ray imaging technologies for tuberculosis screening (opens in a new tab)

  4. A quantitative image evaluation study of a concurrent photon amplification treated emulsion

    … in regard to image quality. The study evaluated detective quantum efficiency (DQE), modulation transfer function (MTF), and information content (IC) as a function of exposure in a comparison between normal exposure and CPA. The results showed CPA to enhance image quality relative to normal …

    rit Repository record for A quantitative image evaluation study of a concurrent photon amplification treated emulsion (opens in a new tab)

  5. MEASUREMENTS OF MODULATION TRANSFER FUNCTION AND SPATIAL NOISE IN INFRARED CCD'S (SPECKLE, INFORMATION THEORY, OPTICS).

    … noise is pursued via the formalism of Detective Quantum Efficiency and also via a two dimensional generalization of the classical representation for information capacity. Suggestions for improving the performance of the array as a signal processor are drawn from these considerations. …

    arizona-thes Repository record for MEASUREMENTS OF MODULATION TRANSFER FUNCTION AND SPATIAL NOISE IN INFRARED CCD'S (SPECKLE, INFORMATION THEORY, OPTICS). (opens in a new tab)

  6. Application of a High‑Resolution Computed Radiography System in Detecting an Iodinated X‑ray Contrast Agent: Small Animal Phantom Study

    … Noise (RSD), Noise Equivalent Quanta (NEQ), and Detective Quantum Efficiency (DQE). Next, dual‑energy and temporal subtraction techniques were implemented to enhance the contrast of iodinated regions and suppress soft tissue background in the phantom. The underlying physics of each technique was …

    tenn-hsc Repository record for Application of a High‑Resolution Computed Radiography System in Detecting an Iodinated X‑ray Contrast Agent: Small Animal Phantom Study (opens in a new tab)

  7. Design, development and characterization of a novel neutron and X-ray combined computed tomography system

    … function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE). This dissertation is a complete overview of the design of the NXCT system, operation, algorithms, performance evaluation and results"--Abstract, page iii.

    must-thes Repository record for Design, development and characterization of a novel neutron and X-ray combined computed tomography system (opens in a new tab)

  8. Characterization and evaluation of a photostimulable phosphor x ray imaging system.

    … imaging plates such as energy-dependent x-ray quantum efficiency, stored signal decay, low exposure rate signal build-up, and spontaneous and stimulated gain measures are presented. The TCR 201 system is characterized by the signal transfer curve, the total root-mean-squared (rms) output noise, …

    arizona-thes Repository record for Characterization and evaluation of a photostimulable phosphor x ray imaging system. (opens in a new tab)

  9. INFORMATION TRANSFER EFFICIENCY OF X-RAY IMAGE INTENSIFIER-BASED IMAGING SYSTEMS.

    The information transfer efficiency of any quantum detection imaging system can be described by a unique measure: the detective quantum efficiency {DQE(f)}, which is a function of the statistically independent frequency channels. The DQE(f) is a combined descriptor which takes into account the …

    arizona-thes Repository record for INFORMATION TRANSFER EFFICIENCY OF X-RAY IMAGE INTENSIFIER-BASED IMAGING SYSTEMS. (opens in a new tab)

  10. Evaluation of digital X-ray detectors for medical imaging applications

    … noise power spectrum (NNPS) and the resultant detective quantum efficiency (DQE). Modifications were introduced to extend the standard methods to overcome technical limitations. The performance of these detectors was compared to three commercial systems (Remote RadEye HR (CMOS APS), Hamamatsu …

    greece Repository record for Evaluation of digital X-ray detectors for medical imaging applications (opens in a new tab)

  11. Ανάπτυξη πληροφοριακού συστήματος στην ακτινολογία

    … reduction in the radiation dose, due to improved detective quantum efficiency. Digital solutions are likely best accomplished with complementary mix of technologies, such as placing DR systems in high work load areas such as dedicated chest rooms and using CR for general radiography applications …

    greece Repository record for Ανάπτυξη πληροφοριακού συστήματος στην ακτινολογία (opens in a new tab)

  12. Modeling of x-ray photoconductors for x-ray image detectors

    … terms of the modulation transfer function (MTF), detective quantum efficiency (DQE), and ghosting of x-ray image detectors have been developed. The modeling works are based on the physics of the individual phenomena and the systematic solution of the fundamental physical equations in the …

    sask Repository record for Modeling of x-ray photoconductors for x-ray image detectors (opens in a new tab)

  13. Hybrid Semiconductor Detectors for High Spatial Resolution Phase-contrast X-ray Imaging

    … distances and thin (and hence low detection efficiency) scintillator-based detectors. Thus, imaging throughput is limited, and the absorbed dose in the sample can be unacceptable for radiation sensitive life science and biomedical applications. This work develops hybrid amorphous selenium and …

    waterloo Repository record for Hybrid Semiconductor Detectors for High Spatial Resolution Phase-contrast X-ray Imaging (opens in a new tab)

  14. Streaking and splashing: design of a grazing incidence x-ray streak camera and time-resolved measurements of the structure of water

    … soft x-rays. The total electron yield and pulsed quantum efficiency has been measured in a reflection geometry as a function of photon energy (100 eV to 1 keV), angle of incidence, and the electric field between the anode and photocathode. The total electron yield and pulsed quantum efficiency …

    dcu Download PDF for Streaking and splashing: design of a grazing incidence x-ray streak camera and time-resolved measurements of the structure of water (opens in a new tab)

  15. Optimization of Imaging Performance and Conspicuity in Dual-Energy X-ray Radiography

    … (NPS), modulation transfer function (MTF), detective quantum efficiency (DQE), and noise-equivalent quanta (NEQ) - were computed using cascaded systems analysis extended to DE imaging and combined with a quantitative model of imaging task to yield estimates of detectability across a broad …

    toronto-retro Repository record for Optimization of Imaging Performance and Conspicuity in Dual-Energy X-ray Radiography (opens in a new tab)

  16. Development of a Flat Panel Detector with Avalanche Gain for Interventional Radiology

    … digital flat panel detectors (FPD) are not x-ray quantum noise limited (QNL) due to the presence of electronic noise which substantially degrades their imaging performance. The goal of this thesis was to investigate how a FPD based on amorphous selenium (a-Se) with internal avalanche …

    toronto-retro Repository record for Development of a Flat Panel Detector with Avalanche Gain for Interventional Radiology (opens in a new tab)

  17. Modeling the Anisotropic Resolution and Noise Properties of Digital Breast Tomosynthesis

    … frequency modulation transfer function (MTF) and detective quantum efficiency (DQE) are degraded due to oblique x-ray incidence. In addition, using the sine plate, it is demonstrated that a reconstruction can resolve frequencies exceeding the detector alias frequency. Experimental images of bar …

    penn Repository record for Modeling the Anisotropic Resolution and Noise Properties of Digital Breast Tomosynthesis (opens in a new tab)

  18. Design, Development, and Characterization of a Prototype Digital Mammography System

    … function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE). Experimental measurements of imager performance was also conducted and compared to model predicted results. Further, perceptual analysis of the prototype imaging platform for digital mammography was performed. …

    gatech Repository record for Design, Development, and Characterization of a Prototype Digital Mammography System (opens in a new tab)

Page 1 of 2