Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 87 for “"Detector arrays"”.

  1. Evaluation of MOSFETs for Terahertz Detector Arrays

    … contain varying structures, providing a range of detectors to analyze. Included are individual test MOSFETs for which various operating parameters and modes are studied and results presented. The focus on single transistor-antenna testing provides a path for discovering the most efficient …

    rit Repository record for Evaluation of MOSFETs for Terahertz Detector Arrays (opens in a new tab)

  2. Detector Arrays for Nuclear Security and Safeguards Applications

    … in the MeV energy range. The use of 3He detectors for fast neutron measurements requires the use of moderators. Detector arrays capable of fast neutron detection are one solution to this problem. To this end, the focus of this work was the study of detector arrays for fast neutron …

    unlv Repository record for Detector Arrays for Nuclear Security and Safeguards Applications (opens in a new tab) Download PDF for Detector Arrays for Nuclear Security and Safeguards Applications (opens in a new tab)

  3. The optical design of far-infrared detector arrays.

    The imaging properties of far infrared detector arrays are analyzed. An arbitrary optical system imaging partially coherent light is reviewed. The imaging and detection process is correlated to the coherence properties of the imaged light. A selection set of optical flux concentrator arrays is set …

    arizona-thes Repository record for The optical design of far-infrared detector arrays. (opens in a new tab)

  4. Optical coherence tomography methods using 2-D detector arrays

    … and detects the signal using a single photodetector. To acquire transverse information, transversal scanning of the illumination point is required. Alternatively, multiple OCT channels can be operated in parallel simultaneously; parallel OCT signals are recorded by a two-dimensional (2D) …

    kent Download PDF for Optical coherence tomography methods using 2-D detector arrays (opens in a new tab)

  5. Signal processing for readout-multiplexed single-photon detector arrays

    … based on superconducting nanowire single-photon detectors (SNSPDs) are desirable due to properties such as near-unity quantum efficiency, low jitter, and high timing resolution. Readout multiplexing has been critical to the first implementations of large-scale SNSPD arrays by mitigating the high …

    bu Repository record for Signal processing for readout-multiplexed single-photon detector arrays (opens in a new tab)

  6. MULTISPECTRAL DATA COMPRESSION USING STAGGERED DETECTOR ARRAYS (LANDSAT, REMOTE SENSING).

    … investigated in which a scene is imaged onto a detector array whose elements vary in spectral sensitivity. The elements are staggered such that the scene is undersampled within any single spectral band, but is sufficiently sampled by the total array. Compression thus results from transmitting …

    arizona-thes Repository record for MULTISPECTRAL DATA COMPRESSION USING STAGGERED DETECTOR ARRAYS (LANDSAT, REMOTE SENSING). (opens in a new tab)

  7. Development of novel gamma detector arrays for industrial and medical applications

    Positron emission particle tracking (PEPT) is a technique directly developed from positron emission tomography (PET) where the position of a positron-emitting radiotracer is calculated from the lines-of-response (LORs) of a PET scanner. First developed at the University of Birmingham in the 1980s …

    birmingham Download PDF for Development of novel gamma detector arrays for industrial and medical applications (opens in a new tab)

  8. Time-resolved Single-photon Detector Arrays for High Resolution Near-infrared Optical Tomography

    … resolution is the low numbers of sources and detectors in conventional systems. In an effort to improve the spatial resolution of NIROT, researchers have recently applied time-resolved cameras based on single photon avalanche diodes (SPADs) to NIROT phantom measurements, achieving a resolution …

    zurich Repository record for Time-resolved Single-photon Detector Arrays for High Resolution Near-infrared Optical Tomography (opens in a new tab) Restricted access

  9. SemiSPECT: A small-animal SPECT imager based on eight cadmium zinc tellurium detector arrays

    … cadmium zinc telluride (CdZnTe) gamma-ray detector arrays. The detector is a 2.5 cm x 2.5 cm x 0.15 cm slab having a 64 x 64 pixel array. A read-out application-specific integrated circuit (ASIC) is attached onto the detector via indium-bump bonding, and a -180 V bias is applied onto the …

    arizona-thes Repository record for SemiSPECT: A small-animal SPECT imager based on eight cadmium zinc tellurium detector arrays (opens in a new tab)

  10. A study of 8Be, 12C and 27Al with state-of-the-art detector arrays

    … of nuclear physics experiment with silicon detectors was developed. This library is built on the concept of an analysis pipeline. Secondly, the Aarhus data acquisition has been rebuilt from the ground up. The different components and recent development allowing significantly higher rates …

    whiterose Download PDF for A study of 8Be, 12C and 27Al with state-of-the-art detector arrays (opens in a new tab)

  11. Optimizing The Performance Of As-manufactured Grazing Incidence X-ray Telescopes Using Mosaic Detector Arrays

    … or the effects of state-of-the-art mosaic detectors. The work presented in this dissertation is in support of the Solar X-ray Imager (SXI) program. We have developed a rigorous procedure by which to analyze detector effects in systems which exhibit severe field-dependent aberrations …

    ucf Repository record for Optimizing The Performance Of As-manufactured Grazing Incidence X-ray Telescopes Using Mosaic Detector Arrays (opens in a new tab)

  12. The use of small neutron detector arrays for the assessment of nuclear materials comprising 235-U, 238-U and 240-Pu

    … power operations. To date, the most common detectors for performing neutron metrology have been 3He detectors. With 3He production in decline, it has become supply-constrained and alternatives are being sought as potential replacements. Liquid organic scintillation detectors are an option, …

    lancaster Download PDF for The use of small neutron detector arrays for the assessment of nuclear materials comprising 235-U, 238-U and 240-Pu (opens in a new tab)

  13. DETECTORS FOR THE COSMOLOGY LARGE ANGULAR SCALE SURVEYOR (CLASS)

    … CLASS is made possible by its background-limited detector arrays. The detector arrays for all CLASS telescopes contain smooth-walled feedhorns that couple to transition-edge sensor (TES) bolometers through symmetric planar orthomode transducers (OMTs). This thesis begins by introducing the …

    jhu Repository record for DETECTORS FOR THE COSMOLOGY LARGE ANGULAR SCALE SURVEYOR (CLASS) (opens in a new tab)

  14. Optimized Single-Electron Bipolar Avalanche Transistors for Innovative THz/IR Imaging Systems

    … antenna-coupled Field-Effect Tran-sitor (FET) detector arrays. Targeting the TeraHertz (THz) and Long-Wavelength Infra-Red (LWIR) spectra, these detectors offer the advantage of room-temperature, vacuum-free opera-tion and compatibility with standard Complementary Metal-Oxide Semiconductor …

    trento Repository record for Optimized Single-Electron Bipolar Avalanche Transistors for Innovative THz/IR Imaging Systems (opens in a new tab)

  15. A VLSI optical detector array employing heterodyne detection

    … signal to noise ratio, as compared to base-band detectors. The unavailability of heterodyne detector arrays has been a bottleneck in many imageprocessing systems, restricting the use of heterodyne detection techniques to scanning based systems, or systems having a single temporal output, such as …

    ttu Repository record for A VLSI optical detector array employing heterodyne detection (opens in a new tab)

  16. Design, Simulation and Prototyping of a Radio-Frequency Calibration System for Neutrino Detection Experiments

    … neutrinos beyond the PeV energy scale requires detectors spanning several cubic kilometers due to the steep decline in neutrino flux at these energies, prompting the development of new detection techniques searching for Askaryan radio emission, capable of monitoring much larger volumes of target …

    ku Repository record for Design, Simulation and Prototyping of a Radio-Frequency Calibration System for Neutrino Detection Experiments (opens in a new tab)

  17. Magnetic Fields in Molecular Clouds: The Blastpol and Blast-Tng Experiments

    … mirror and more than 3000 polarization sensitive detectors. BLAST-TNG will observe in the same three bands as BLASTpol at 250, 350, and 500 microns. The telescope will serve as a pathfinder project for microwave kinetic inductance detector (MKID) technology, as applied to feedhorn coupled …

    penn Repository record for Magnetic Fields in Molecular Clouds: The Blastpol and Blast-Tng Experiments (opens in a new tab)

  18. STUDY OF SELF-HEATING EFFECT OF MICROBOLOMETER INFRARED DETECTOR AND ITS COMPENSATION TECHNIQUE

    … during the readout of microbolometer IR detectors and demonstrated a compensation technique using reference microbolometer arranged in a Wheatstone bridge read-out circuit. Finally, the concept is extended for application in focal plane arrays and a possible circuit configuration is given …

    nus Download file for STUDY OF SELF-HEATING EFFECT OF MICROBOLOMETER INFRARED DETECTOR AND ITS COMPENSATION TECHNIQUE (opens in a new tab)

  19. Signal processing and incoherent-MIMO for multimode optical fibers

    … to analyze and design the geometry of laser and detector arrays for MIMO-MMF links, and study how the design of these arrays impacts link performance. These models are also used to develop and evaluate low-complexity algorithms that efficiently utilize dense detector arrays, with "greedy subset …

    texas Repository record for Signal processing and incoherent-MIMO for multimode optical fibers (opens in a new tab)

  20. Imaging Fourier transform spectroscopy from a space based platform : the Herschel/SPIRE Fourier transform spectrometer

    … spectrometer (FTS) coupled with bolometric detector arrays to form an imaging FTS (IFTS). This thesis presents experiments conducted to verify the performance of an IFTS system from a space based platform, i.e. the use of the SPIRE IFTS within the Herschel space observatory. Prior to launch, …

    lethbridge Repository record for Imaging Fourier transform spectroscopy from a space based platform : the Herschel/SPIRE Fourier transform spectrometer (opens in a new tab)

Page 1 of 5