Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 48 for “"Detector calibration"”.
-
Measuring Light Distribution of LED Sources for Hyper-Kamiokande Detector Calibration
… Hyper-Kamiokande experiment uses water-Cherenkov detectors to study neutrino oscillation and charge conjugation parity (CP) violations with high precision. To reduce systematic errors, multi-photomultiplier tube modules (mPMTs) that comprise the Cherenkov photon detectors will include LED light …
-
Solid state x-ray detector calibration techniques and LINAC beam intensity measurements
… arrangement allows continuous, in-situ energy calibration of our Si(Li) detector in the electromagnetic noise environment of the linac. This technique was originally developed to perform absolute production efficiency measurements of parametric x-ray generation in the 5-60 KeV range
-
A Study of Electron Energy Response Measurement in the NOvA Test Beam Detector
… oscillations between two functionally-identical detectors; a 300-ton Near Detector and a 14 kton Far Detector separated by 809 km and placed 14 mrad off-axis to the Neutrinos at the Main Injector (NuMI) neutrino beam produced at Fermi National Accelerator Laboratory (Fermilab). NOvA has key …
-
A Prompt D-D Neutron Calibration Of A Plastic Scintillator Detector
… calibrated in neutrons/ count. The initial calibration of the stable neutron generator used in the scintillator calibration was performed using a silver activation detector (PT-502) designed by LASL. The data obtained for the distance curve in this work was least squares fit to with the …
-
Calibration of liquid argon time projection chambers using ambient radioactivity and activity from ²²⁰Rn injection
… an intense neutrino beam at Fermilab, a near detector to measure the neutrinos before oscillations, and a far detector (800 miles away) in Lead, South Dakota to measure the neutrinos after oscillations. Because neutrinos are neutral, their properties must be inferred by detecting the charged …
-
Calibration of Detectors for the Tomographic Ionized-carbon Mapping Experiment
… at millimeter (mm) wavelengths require accurate calibrations for the spectrometers to work with radio telescopes. However, calibrating is a complex and lengthy process for sensitive detectors that catch single photons. To improve efficiency in locating defective detectors and optimizing bias …
-
Data Analysis of Resonant Proton Scattering in Inverse Kinematics
… during the summer of 2012. The main focus is detector calibration, data analysis and interpretation of the experimental data. A radioactive beam of 21Na at 3 MeV/u was impinging on a 5.6 mg/cm2 polyethylene,(CH2)n, target in vacuum. Ejectile protons from nuclear reactions of the beam and the …
-
Analysis of Adjoint Flux Calculation for Detector Response Estimation in Typical PWR Conditions
… estimate the neutron flux which will reach the detector position we can accurately estimate the power level and power distribution for a variety of operating conditions. The analysis presented here seeks to establish a minimum parameter set for solving an adjoint reactor problem at given …
-
Characterization of the Xenon-10 Dark Matter Detector with regard to electric field and light response
… Carlo Simulations of the Xenon-10 Dark Matter Detector were carried out. Electrostatic simulations led to optimization of the charge sensitive region through proper determination of resistor chain values for the field shaping wires and through maximization of the charge sensitive region by …
-
Phonon Mediated Quantum Efficiency Measurement for Low Energy Electronic Recoil Calibration
… cloud. This method lays the groundwork for detector calibration in rare particle searches which intend to explore below current limits. In Dark Matter searches, this mass limit has recently descended below 1MeV/c2, for which the expected signal would be on the order of 1eV , just above the …
-
Phonon Mediated Quantum Efficiency Measurement for Low Energy Electronic Recoil Calibration
… cloud. This method lays the groundwork for detector calibration in rare particle searches which intend to explore below current limits. In Dark Matter searches, this mass limit has recently descended below 1MeV/c2, for which the expected signal would be on the order of 1eV , just above the …
-
Cosmic Ray and Neutrino Astrophysics with the Anita Iii Telescope
… of UHE particles. It covers the theory, payload, detector calibration, signal simulation, and presents results of a search for UHECRs and UHE s with the third ANITA ight.
-
The Design of Gas Chromatography Ionisation Detectors:A Study of the Electron Capture Detector and the Home Ionisation Detector
Two gas ionization detectors were studied from an instrument designer's point of view. Experimental results indicate that the electron capture detector is sensitive to carrier gas density and to atmospheric oxygen. The finite conductivity of electrode insulators was also found to play an important …
-
Measurement of Exclusive Photo-Production of K+ Σ*- Quasi-Free off Neutrons In Deuterium
… the CEBAF Large Acceptance Spectrometer (CLAS) detector system and the tagger system during the EG3 run period from December 2004 to February 2005. Tagged photons with energies from 1.5 to 5.5 GeV are measured in coincidence with K + p π-π- in the spectrometer for this channel. After careful …
-
Measurement of the pion charge exchange differential cross section on Argon with the ProtoDUNE-SP detector
… matter. As a crucial prototype for the DUNE far detector (FD) module, ProtoDUNE-SP at CERN Neutrino Platform Facility employs a hadron test beam with a momentum range of 0.3 to 7 GeV/c to study the detector response to particles that could be produced in the neutrino interactions at the DUNE FD. …
-
An inverse gas-solid chromatographic study of the adsorption heterogeneity of aluminum oxide powders used in ceramic processing
… of the various steps involved, such as detector calibration and relationship between the chromatographic peak shape and the adsorption isotherm is presented. A new method for determination of the adsorption energy distribution function, which is applicable to any convex upwards …
-
Automated isotope identification algorithms for low-resolution gamma spectrometers
… for nuclear security applications, but these detectors generally have poor isotope identification performance. Most of these deployed detectors use low-resolution NaI scintillators due to their low cost and good efficiency. Alternative detection hardware could be used to improve performance, …
-
A Radiogenic Background Model for the MAJORANA DEMONSTRATOR
… a modular array of high-purity germanium (HPGe) detectors with support and shielding constructed from low-background materials and housed at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota. The two modules of the experiment contain 44.8 kg of p-type …
-
Benchmarking of neutron flux parameters at the USGS TRIGA reactor in Lakewood, Colorado
… wires. A well calibrated and stable germanium detector setup as well as fourteen samplers were designed and built to achieve accuracy in the measurement of the neutron flux. Furthermore, the flux monitoring bores of the GSTR core were used for the first time to measure neutron flux …
Page 1 of 3