Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 4 of 4 for “"Detector positioning"”.

  1. Detector positioning in a field-deployable limited-angle gamma ray emission tomography system

    … object of interest. Nevertheless, if a sample or detector rotation is not achievable due to dimension limitations or accessibility, a limited-angle tomography technique (sometimes called Laminography) can be performed via scans from a limited angular range. And, the limited captured data will be …

    uoit Repository record for Detector positioning in a field-deployable limited-angle gamma ray emission tomography system (opens in a new tab)

  2. Image-Guided Interventions Using Cone-Beam CT: Improving Image Quality with Motion Compensation and Task-Based Modeling

    … of low-contrast structures by computing source–detector trajectories that are optimal to a particular imaging task. The approach is applicable to CBCT systems with the capability for general source–detector positioning, as with a robotic C-arm. A “task-driven” analytical framework is introduced, …

    jhu Repository record for Image-Guided Interventions Using Cone-Beam CT: Improving Image Quality with Motion Compensation and Task-Based Modeling (opens in a new tab)

  3. Development of a Prototype AWSM-PET System for Augmented Whole-body PET Imaging

    … technique integrating high-resolution auxiliary detectors with a clinical PET scanner to enhance sensitivity and resolution while remaining fully compatible with standard clinical protocols. The study encompasses hardware development, image reconstruction methods, and performance evaluation …

    wustl Repository record for Development of a Prototype AWSM-PET System for Augmented Whole-body PET Imaging (opens in a new tab)

  4. Phantom and computational studies towards the clinical translation of gas in scattering media absorption spectroscopy into neonatal respiratory care

    … were created to study the influence of source detector positioning and chest physiognomy in the GASMAS signals. A functional phantom resembling the anatomy, temperature and humidity of the respiratory zone, was also developed to investigate the potential of GASMAS technique in measuring changes …

    cork Repository record for Phantom and computational studies towards the clinical translation of gas in scattering media absorption spectroscopy into neonatal respiratory care (opens in a new tab)