Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 270 for “"Detector response"”.

  1. Evaluation of Smoke Detector Response Estimation Methods

    … methods exist to provide estimates of smoke detector response based on optical density, temperature rise, and gas velocity thresholds. The objective of this study was to assess the uncertainty associated with these estimation methods. Experimental data was used to evaluate recommended alarm …

    maryland Repository record for Evaluation of Smoke Detector Response Estimation Methods (opens in a new tab)

  2. Detector Response Simulations of Hydrocarbon Neutron Scintillators

    DESCANT is a novel neutron detector array for use in nuclear structure and astrophysics studies with radioactive-ion beams. Comprised of 70 hexagonical deuterated scintillation detectors, DESCANT is located at the ISAC facility of TRIUMF, where it can be used in combination with the GRIFFIN or …

    guelph Repository record for Detector Response Simulations of Hydrocarbon Neutron Scintillators (opens in a new tab)

  3. Fused silica Cherenkov detector response to MeV photons

    The quartz detectors response to 15 MeV to 55 MeV gamma-ray is investigated to understand the contribution of photon background to the MOLLER (Measurement Of a Lepton-Lepton Electroweak Reaction) experiment. The probability of a monoenergetic photon beam interacting with the quartz detector was …

    manitoba Repository record for Fused silica Cherenkov detector response to MeV photons (opens in a new tab)

  4. The Effect of Bonner Sphere Borehole Orientation on Neutron Detector Response

    … investigates the differences in Bonner Sphere detector response for anisotropic neutron fields as a function of borehole orientation. Monte Carlo simulations using MCNPX were used to calculate the difference for a borehole oriented directly behind a unidirectional neutron field and one in which …

    ut-knoxville Repository record for The Effect of Bonner Sphere Borehole Orientation on Neutron Detector Response (opens in a new tab)

  5. Study of LaBr3 (Ce) detector response to high energy helium ions

    … devices. Lanthanum Bromide scintillator detector (LaBe3: Ce) has been successfully used as a gamma spectrometer inside space crafts. However, data on its response to other particles such as charged particles remains limited. From a radiation protection perspective, it is important to …

    uoit Repository record for Study of LaBr3 (Ce) detector response to high energy helium ions (opens in a new tab)

  6. Investigation of the bubble detector response to high LET space radiation

    … particles. A special type of superheated droplet detectors referred to as space bubble detectors (SBD) have been used to evaluate the equivalent dose due to neutrons in various space missions aboard the International Space Station. Protons and other heavy charged particles are a significant …

    uoit Repository record for Investigation of the bubble detector response to high LET space radiation (opens in a new tab)

  7. The determination of the helium discharge detector response to fixed gases

    The Beckman Helium Discharge Detector has been found to be sensitive to the fixed gases oxygen, nitrogen, and hydrogen at detection levels 10-100 times more sensitive than possible with a Bow-Mac Thermal Conductivity Detector. Detection levels o~ approximately 1.9 E-4 ~ v/v oxygen, 3.1 E-4 ~ v/v …

    brock Repository record for The determination of the helium discharge detector response to fixed gases (opens in a new tab)

  8. Detector response calibration for the NOvA quasi-elastic cross-section measurement

    … neutrinos for this observation. The Near and Far Detectors are constructed off-axis of the NuMI beam line and located at Fermilab and northern Minnesota (electron neutrino appearance maximum), respectively. In order to carry out the long-term goals of the experiment, the NOvA Near Detector …

    iastate Repository record for Detector response calibration for the NOvA quasi-elastic cross-section measurement (opens in a new tab)

  9. Analyzing Photo-Electric Smoke Detector Response Based On Aspirated Smoke Detector Obscuration

    Accurate obscuration levels at the response time of photo-electric smoke detectors are needed for proper detection modeling and analysis. In recent works, obscuration meters were used to measure the obscuration level at photo-electric detector response. In this study, aspirated smoke detectors …

    maryland Repository record for Analyzing Photo-Electric Smoke Detector Response Based On Aspirated Smoke Detector Obscuration (opens in a new tab)

  10. A Hybrid Radiation Transport Detector Response Function Methodology for Modeling Contaminated Sites

    … techniques – specifically relating photon detector responses to dose or cancer risk-based radionuclides concentrations in environmental media – exist under the Environmental Protection Agency (EPA) Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). In recent …

    gatech Repository record for A Hybrid Radiation Transport Detector Response Function Methodology for Modeling Contaminated Sites (opens in a new tab)

  11. Analysis of Adjoint Flux Calculation for Detector Response Estimation in Typical PWR Conditions

    … estimate the neutron flux which will reach the detector position we can accurately estimate the power level and power distribution for a variety of operating conditions. The analysis presented here seeks to establish a minimum parameter set for solving an adjoint reactor problem at given …

    ut-knoxville Repository record for Analysis of Adjoint Flux Calculation for Detector Response Estimation in Typical PWR Conditions (opens in a new tab)

  12. Sensing the shape of spacetime: detector response and entanglement harvesting in curved space

    … to understand what information Unruh-DeWitt detectors can gain about the structure of spacetime. By coupling to the quantum state of a field on a curved space, the detectors can gain information about their surroundings, beyond their proper acceleration. They can then receive more information …

    waterloo Repository record for Sensing the shape of spacetime: detector response and entanglement harvesting in curved space (opens in a new tab)

  13. Optimization of detector response simulations for multiple particles created by neutron-induced reactions

    … system, and studies the optimization of detector response simulations for multiple particles created by neutron-induced reactions. Neutron Activation Analysis (NAA) method was used to investigate the influence of the trace element, chlorine, in the biological system of the human body using …

    uiuc Repository record for Optimization of detector response simulations for multiple particles created by neutron-induced reactions (opens in a new tab)

  14. FABRICATION, MEASUREMENTS, AND MODELING OF SEMICONDUCTOR RADIATION DETECTORS FOR IMAGING AND DETECTOR RESPONSE FUNCTIONS

    … The alpha-tagging sensor is a double-sided strip detector made from polycrystalline CVD diamond. The performance goals of the alpha-tagging sensor are 700-picosecond timing resolution and 0.5 mm spatial resolution. A literature review summarizes the methodology, goals, and challenges in associated …

    utk-theses Repository record for FABRICATION, MEASUREMENTS, AND MODELING OF SEMICONDUCTOR RADIATION DETECTORS FOR IMAGING AND DETECTOR RESPONSE FUNCTIONS (opens in a new tab)

  15. Study of neutron detector response and related systematic uncertainties in the NOvA oscillation analysis

    … that is comprised of two functionally identical detectors positioned 810km apart. One of the main goals of the experiment is to measure electron neutrino appearance and muon neutrino disappearance at the Far Detector (FD) using neutrinos originating from the NuMI Beam at Fermilab. NOvA uses these …

    iastate Repository record for Study of neutron detector response and related systematic uncertainties in the NOvA oscillation analysis (opens in a new tab)

  16. Development of a Novel Detector Response Formulation and Algorithm in RAPID and its Benchmarking

    … solving such problems. In this dissertation, the Detector Response Function (DRF) methodology is proposed and developed for real-time and accurate radiation shielding calculation. The real-time capability of solving radiation shielding problem is very important for: (1) Safety and monitoring of …

    vt Repository record for Development of a Novel Detector Response Formulation and Algorithm in RAPID and its Benchmarking (opens in a new tab)

  17. Determination of detector response to ℓ/ℓ sources using the ITS Monte Carlo Code System

    … survey community is the variation of detector response to specific conditions. Several types of portable detectors used for frisking and routine field surveys are modelled using the ITS Monte Carlo Code System. The detectors modelled include Pancake Geiger-Mueller (PGM) counters, …

    ut-knoxville Repository record for Determination of detector response to ℓ/ℓ sources using the ITS Monte Carlo Code System (opens in a new tab)

Page 1 of 14