Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 45 for “"Diagnostic reliability"”

  1. Diagnostic Reliability of Guidewire in Evaluation of Coronary Artery Stenoses

    The purpose of this thesis is to evaluate the diagnostic reliability of guidewires in analyzing the severity of coronary stenoses (blockages) through combined flow and pressure measurements. It is hypothesized that presence of a guidewire will produce an obstructive effect and, thus an additional …

    ohiolink Repository record for Diagnostic Reliability of Guidewire in Evaluation of Coronary Artery Stenoses (opens in a new tab)

  2. A biopsychosocial approach to vulvar vestibulitis syndrome : diagnostic reliability and treatment outcome

    … vestibulitis literature, covering descriptive, diagnostic, etiologic, and treatment aspects. This is followed by a retrospective study of 38 women, investigating the success of vestibulectomy, a frequently recommended medical treatment for vulvar vestibulitis. Results from structured telephone …

    mcgill Repository record for A biopsychosocial approach to vulvar vestibulitis syndrome : diagnostic reliability and treatment outcome (opens in a new tab)

  3. Re-evaluating vaginismus : an empirical investigation of diagnostic reliability, vaginal spasm, pain, and associated etiological correlates

    … psychological distress were administered. The reliability of vaginal muscle spasm as the main diagnostic criterion, differential diagnosis, and the role of pain were assessed via by 2 separate gynecological and, 2 separate physical therapist examination, 2 EMG evaluations, and a review of the …

    mcgill Repository record for Re-evaluating vaginismus : an empirical investigation of diagnostic reliability, vaginal spasm, pain, and associated etiological correlates (opens in a new tab)

  4. Agreement in classification choices by school psychologists when evaluating children for special education placement

    <p>A lack of diagnostic reliability among school and clinical psychologists has plagued the field for years. Diagnostic agreement rarely exceeds chance by more than a few percentage points. This study examined the level of agreement when school psychologists studying only objective data attempted …

    utk-theses Repository record for Agreement in classification choices by school psychologists when evaluating children for special education placement (opens in a new tab)

  5. Semantic preserving generative AI for machine vision

    … such as microvasculature, undermining both diagnostic reliability and quantitative analysis. This limitation is consequential in ophthalmic and vascular imaging, where subtle morphological changes carry significant clinical meaning. We propose Curvilinear Structure-preserving Translation …

    nanyang Repository record for Semantic preserving generative AI for machine vision (opens in a new tab)

  6. ENHANCING SAMPLING METHODS WITHIN GRIFOLS CLINICAL LABORATORY IN MEMPHIS: RELATIVE HUMIDITY DEVIATIONS AND STRATEGIES FOR CONTROL

    … testing equipment performance, and overall diagnostic accuracy. Part one of this investigation analyzed ambient relative humidity readings within Grifols’ Memphis Nucleic Acid Testing [NAT] Laboratory during June 2025. The findings revealed elevated humidity deviations. Building on these …

    jhu Repository record for ENHANCING SAMPLING METHODS WITHIN GRIFOLS CLINICAL LABORATORY IN MEMPHIS: RELATIVE HUMIDITY DEVIATIONS AND STRATEGIES FOR CONTROL (opens in a new tab)

  7. Studying the Impact of Imaging Artifacts on CNN-Based Brain Cancer Detection

    … noise, contrast, and ringing can compromise the reliability of CNN models. In this study, we investigate the impact of these artifacts on CNN performance by introducing 10 levels of each artifact on MRI scans. We also generate artifacts with similar Structural Similarity Index (SSIM) to assess …

    texas-state Repository record for Studying the Impact of Imaging Artifacts on CNN-Based Brain Cancer Detection (opens in a new tab)

  8. Detectability of osseous lesions with a pre-programmed low-dose protocol for cone-beam computed tomography

    The present study aimed to compare the diagnostic reliability of a pre-set, manufacturer-specific, low-dose mode against a standard-dose mode in the detection of four different osseous lesions in the mandible with cone-beam computed tomography (CBCT). Four types of lesions (periapical lesion, …

    zurich Repository record for Detectability of osseous lesions with a pre-programmed low-dose protocol for cone-beam computed tomography (opens in a new tab) Restricted access

  9. Production and characterization of diagnostic-grade recombinant allergens: from expression platform selection to clinical application /

    … IgE antibodies and T helper cells. Conventional diagnostics rely on allergen extracts derived from natural sources, but their variability and limited standardization reduce assay accuracy and reproducibility. Recombinant allergens provide defined allergen molecules that enable the precise …

    vilnius Repository record for Production and characterization of diagnostic-grade recombinant allergens: from expression platform selection to clinical application / (opens in a new tab)

  10. Examining the Use of Hebephilia and Paraphilia Non-consent in Sexually Violent Predator (SVP) Evaluations

    … evaluations. Since these studies, however, the Diagnostic and Statistical Manual (DSM) has updated the paraphilia NOS diagnosis in two ways. First, this diagnosis has been divided into two new diagnoses—other specified paraphilic disorder (OSPD) and unspecified paraphilic disorder. Second, OSPD …

    cuny-grad Repository record for Examining the Use of Hebephilia and Paraphilia Non-consent in Sexually Violent Predator (SVP) Evaluations (opens in a new tab)

  11. Can Application of Artifact Reduction Algorithm or Increasing Scan Resolution Improve CBCT Diagnostic Accuracy of TAD - Tooth Root Contact?

    … images independently. Subsequently, CBCT diagnostic reliability and accuracy were assessed, using micro-CT as gold standard. Results: Cohen’s kappa tests showed moderate to strong intra-rater and inter-rater reliability of CBCT diagnoses. For CBCT diagnostic accuracy, there was a higher …

    ohiolink Repository record for Can Application of Artifact Reduction Algorithm or Increasing Scan Resolution Improve CBCT Diagnostic Accuracy of TAD - Tooth Root Contact? (opens in a new tab)

  12. Attitudes and Beliefs of Nurse Practitioners to Augment Breast Cancer Screening with Ultrasonography

    Recent studies have suggested that the diagnostic reliability and accuracy of breast ultrasonography in place of mammography in women with dense breast tissue results in more accurate breast cancer screening in this population. Since breast cancer is the second leading cause of cancer deaths among …

    arizona-thes Repository record for Attitudes and Beliefs of Nurse Practitioners to Augment Breast Cancer Screening with Ultrasonography (opens in a new tab)

  13. Clinical evaluation of optically tracked ultrasound system to support diagnosis of developmental dysplasia of the hip

    … using deep learning has demonstrated improved diagnostic reliability; however, the high cost and limited availability of 3DUS systems restrict their widespread adoption in routine pediatric care. To address this gap, we developed and evaluated an optically tracked 2D ultrasound (OTUS) system, …

    ubc Repository record for Clinical evaluation of optically tracked ultrasound system to support diagnosis of developmental dysplasia of the hip (opens in a new tab)

  14. Improving Diagnostic Yield and Time-to-Diagnosis of Rare Disease by Developing AI-Based Algorithms

    … workflows can enhance time to diagnosis and diagnostic yield, this thesis presents an ML framework designed to support the interpretation of clinical variants by combining supervised classification with evolutionary gene prioritization and evaluating its performance within an accredited …

    barcelona Repository record for Improving Diagnostic Yield and Time-to-Diagnosis of Rare Disease by Developing AI-Based Algorithms (opens in a new tab)

  15. Periodontal health and HIV infection

    … HIV infection. The first study aimed to develop diagnostic criteria for periodontal changes associated with HIV. Criteria were derived by experienced dentists and tested in a formal experiment. Training with the criteria improved diagnostic reliability. The second study aimed to identify the …

    ucl Repository record for Periodontal health and HIV infection (opens in a new tab)

  16. An Intelligent System for Bearing Condition Monitoring

    … system for more reliable bearing fault diagnostics. This system involves two sequential processes: feature extraction and decision-making. The proposed strategy is to develop advanced and robust techniques at each processing stage so as to improve the reliability of bearing condition …

    waterloo Repository record for An Intelligent System for Bearing Condition Monitoring (opens in a new tab)

  17. A research platform for ultrasonic elastograpy based targeted prostate biopsy

    … promises higher cancer yields and improved diagnostic reliability, while at the same time decreasing procedural side effects by reducing the number of required core samples. The objective of this thesis has been to integrate the elastography imaging modality into a standard prostate biopsy …

    ubc Repository record for A research platform for ultrasonic elastograpy based targeted prostate biopsy (opens in a new tab)

Page 1 of 3