  1. Mathematical modeling of mass transfer in a hollow fiber dialyzer

    … transfer has been developed for the hollow fiber dialyzer in countercurrent dialysis. The theoretical expressions are developed from a typical Graetz problem for the stream side, and a first order differential equation for the dialyzate side. The solution of the dimensionless concentration profile …

    njit Repository record for Mathematical modeling of mass transfer in a hollow fiber dialyzer (opens in a new tab)

  2. Migration of blood cells in non-uniform suspension for a dialyzer design

    … and increase the waste removal rate, a new dialyzer (filter) design is proposed in this study. In the new dialyzer design, the blood concurrently flows with a sheath fluid in a micro-fluidic channel. Because the blood stream directly contacts the sheath stream, it is important to prevent …

    gatech Repository record for Migration of blood cells in non-uniform suspension for a dialyzer design (opens in a new tab)

  3. STUDY OF DIALYZER MEMBRANE (POLYFLUX 210H) AND EFFECTS OF DIFFERENT PARAMETERS ON HEMODIALYSIS PERFORMANCE

    … Parameters characterizing the structure of dialyzers are very important because they decide overall clearance of toxin molecules and at the same time should allow retaining useful molecules in the blood. It is however not clear how the changes of dialyzer parameters will affect the …

    sask Repository record for STUDY OF DIALYZER MEMBRANE (POLYFLUX 210H) AND EFFECTS OF DIFFERENT PARAMETERS ON HEMODIALYSIS PERFORMANCE (opens in a new tab)

  4. Intradialytic Heparin Reduction & Validation of Extracorporeal Circuit Subjective Clotting Scale Study

    … patients, 2) Is there a relationship between the dialyzer clotting scale and the ultrasound based FBV measurement, and 3) Is the visual dialyzer clotting scale used for the study reliable? Use of the study protocol significantly reduced cumulative heparin dose (p=<0.001); without affecting KT/V …

    calgary Repository record for Intradialytic Heparin Reduction & Validation of Extracorporeal Circuit Subjective Clotting Scale Study (opens in a new tab)

  5. Computational Modeling of Hollow-Fiber Hemodialyzers (Artificial Kidneys)

    Hollow-fiber hemodialyzers are widely used medical devices for removing uremic toxins from blood. Despite their introduction in the 1960s, their design has seen limited advancement, and several performance limitations remain unresolved. Computational modeling offers a powerful alternative to …

    vt Repository record for Computational Modeling of Hollow-Fiber Hemodialyzers (Artificial Kidneys) (opens in a new tab)

  6. Design and modeling of a portable hemodialysis system

    … Work largely focuses on developing a better dialyzer - the component that is directly responsible for removing wastes from the blood - but less study is devoted to the entire hemodialysis system. This work seeks to improve hemodialysis in two ways: by proposing a new renal replacement therapy …

    gatech Repository record for Design and modeling of a portable hemodialysis system (opens in a new tab)

  7. Protein-bound uremic toxin kinetics modeling for a new dialysis device

    … consists of a three-compartment patient model, a dialyzer model and toxin removal unit models where the PBUTs adsorption model can be plugged in. With these models, the effect of various parameters affecting adsorption process are discussed in detail.

    washington Repository record for Protein-bound uremic toxin kinetics modeling for a new dialysis device (opens in a new tab)

  8. A mathematical model for simulation of solute transport within the patient-artificial kidney system

    … Uremic Toxicity has introduced the need for hemodialyzers capable of efficiently removing metabolites with molecular weights between 300 and 2000. The rate at which these solutes can be removed from the body depends not only upon the efficiency of the dialyzer, but also upon the ability of the …

    texas Repository record for A mathematical model for simulation of solute transport within the patient-artificial kidney system (opens in a new tab)

  9. Nano-enhanced Dialytic Fluid Purification System: Applications and Computational Fluid Dynamics Modeling of a Nanoadsorbent Slurry

    … in proof-of-concept experiments using a dialyzer with a single tubular membrane. Stagnant solutions of arsenic or lead were added into the lumen of the membrane and dialyzed using a flowing stream of ferrihydrite or hexagonal birnessite nanoparticles, respectively, over a three hour …

    temple Repository record for Nano-enhanced Dialytic Fluid Purification System: Applications and Computational Fluid Dynamics Modeling of a Nanoadsorbent Slurry (opens in a new tab)

  10. The Infusion of Scaled Amounts of Normal Saline During the Initiation of Hemodialysis and the Incidence of Hypotension

    … and the giving of saline utilized to prime the dialyzer blood tubing were concluded to be noncontributory to the induction of shock episodes. Those who gained more weight between treatments received less fluid and had a greater circulating volume prior to the initiation of treatment and the …

    marquette Repository record for The Infusion of Scaled Amounts of Normal Saline During the Initiation of Hemodialysis and the Incidence of Hypotension (opens in a new tab)

  11. Experimental Validation of Computational Model for Circulating Albumin Dialysis and Optimization of Conditions

    … by traditional dialysis methods. By design, dialyzer pores do not allow carrier proteins like albumin or ceruloplasmin to cross the membrane. Many medical conditions such as liver failure and cholestasis are defined in part by an excess of PBTs such as bilirubin, cholic acid, copper, or …

    washington Repository record for Experimental Validation of Computational Model for Circulating Albumin Dialysis and Optimization of Conditions (opens in a new tab)

  12. Design of a capillary artificial kidney

    … capillary, the characteristics of a composite dialyzer were determined in terms of certain physiological parameters. The system was optimized by maximizing the mass transfer efficiency with respect to the membrane area. The analysis predicted the best capillary diameter in terms of the …

    ubc Repository record for Design of a capillary artificial kidney (opens in a new tab) Download PDF for Design of a capillary artificial kidney (opens in a new tab)

  13. Development and Implementation of a DSP Based Air Detector System to Prevent Embolism During Hemodialysis Therapy

    … hemodialysis are performed through the use of a dialyzer, which is also known as an artificial kidney. During hemodialysis small air bubbles may infiltrate the tubing used during the therapy and combine to form larger air bubbles that are harmful to the patient. If an air bubble is large enough …

    usf Repository record for Development and Implementation of a DSP Based Air Detector System to Prevent Embolism During Hemodialysis Therapy (opens in a new tab)

  14. The magnitude of hepatitis C and hepatitis B virus infections in chronic hemodialysis patients with end stage renal disease in a low-resource healthcare setting in Vietnam: implications for infection control

    … community. Overall, 99% of patients reused dialyzers and none were HBV vaccinated. Having a HBV positive sexual partner increased the risk of acquiring HBV while the risk for HCV included blood transfusion, multiple hemodialysis unit visits and prolonged hemodialysis. Over the 2 year …

    unsw Repository record for The magnitude of hepatitis C and hepatitis B virus infections in chronic hemodialysis patients with end stage renal disease in a low-resource healthcare setting in Vietnam: implications for infection control (opens in a new tab)

  15. Citrate kinetics during regional citrate anticoagulation in extracorporeal organ replacement therapy

    … clearance of citrate-calcium complexes by F60S dialyzers. In addition, a mathematical model was developed to identify the parameters affecting calcium and citrate kinetics in order to predict citrate and calcium requirements in individual patients to avoid side effects. <br>Citrate and calcium …

    freiburg-diss Repository record for Citrate kinetics during regional citrate anticoagulation in extracorporeal organ replacement therapy (opens in a new tab)

  16. Medical Simulation-Based Sensor Methods for Ultrasound-Guided Dialysis Cannulation Skill Assessment

    … and water from your blood externally via a dialyzer. Patients on hemodialysis require a vascular access, typically an arteriovenous fistula (AVF) or arteriovenous graft (AVG) for dialysis, which is used three times a week for about four hours a session. These life-saving therapies can be …

    clemson Repository record for Medical Simulation-Based Sensor Methods for Ultrasound-Guided Dialysis Cannulation Skill Assessment (opens in a new tab)

  17. Validação do diagnóstico de enfermagem risco de glicemia instável em pacientes submetidos à hemodiálise

    … conditions of Diabetes Mellitus and high-flow dialyzer use, as well as the at-risk population of patients with a longer diagnosis of diabetes mellitus and elderly individuals, were able to increase the chances of developing the risk of ineffective selfmanagement of blood glucose pattern. It is …

    brazil-ufrn Repository record for Validação do diagnóstico de enfermagem risco de glicemia instável em pacientes submetidos à hemodiálise (opens in a new tab)

  18. Using Low-cost Sensors to Verify a Fully Mixed Peritoneal Dialysis Solution for On-site Production in Low- and Middle-Income Countries

    … ESKD patients. An external filter, known as a dialyzer, removes waste and excess fluid in the blood through osmotic and concentration gradients with the assistance of a concentrated fluid, the dialysate. In contrast, PD is a daily RRT treatment for ESKD patients performed in a dialysis clinic, …

    umn Repository record for Using Low-cost Sensors to Verify a Fully Mixed Peritoneal Dialysis Solution for On-site Production in Low- and Middle-Income Countries (opens in a new tab)