Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 100 for “"Diaphysis"”.
-
Fracture of the tibial diaphysis: epidemiology, management and outcomes
Introduction Tibial shaft fractures represent 2% of all fractures. A high percentage of them present as open fractures possessing a higher incidence of local complications. An accurate description of the epidemiology and outcomes of these injuries is lacking and often based on small or outdated …
-
Femoral Biomechanical Analyses and 3D Printed Femoral Diaphysis for Biomechanical Simulation
BACKGROUND: The biomechanical properties of adult human femurs have significant clinical and surgical implications. Despite an extensive body of literature, a consolidated analysis of those material properties has not been firmly established. Furthermore, the results and limitations of cadaveric …
-
Variability of Strain and Strain Rate in the Human Tibial Diaphysis During Walking
With the prevalence of stress fractures in the military and athletes of all levels, research into the pathology of this injury has taken flight in recent years. One area of research has focused on the role bone strain, which is known to be a factor in bone remodeling, has on stress fracture …
-
Quantitative Biomechanical Evaluation of Upper Extremity: Strain Behavior of the Humerus Diaphysis Under Loading
… rigidity. Strain characteristics of the humerus diaphysis as a function of loading provide a valuable addition to the currently limited knowledge. The objective of this dissertation was to accomplish this goal, using numerical/finite element (FE) methods applied to a standard anatomic humerus …
-
Relating cortical bone mechanics to intracortical pore morphology, distribution and remodeling history within the fibula diaphysis
… SED. Methods: The study was conducted on fibula diaphysis specimens from 20 patients undergoing a jaw reconstruction (age range 41-75 years, 18 men and 8 women). Specimens were plastic embedded, µCT-scanned and sectioned for histology. Three-dimensional micro-finite element models of each …
-
Correlations of the mechanical properties of the cortical and compact bone of the femoral neck to those of the femoral diaphysis
Includes bibliographical references (pages 161-166).
-
Intra-bone heterogeneity of recoverable DNA from fresh, buried, and exposed femora
… usually from cortical bone of the midshaft diaphysis. Although this strategy is often successful, the femur has extensive differences in morphology, tissue composition, and points of articulation that may differ in DNA content. In the research presented, intra-femoral heterogeneity was …
-
An Investigation of Humeral Stress Fractures in Racing Thoroughbreds Using a 3D Finite Element Model in Conjunction with a Bone Remodeling Algorithm
… with a control location called the caudal diaphysis. It was found that race programs exhibited similar remodeling patterns between each other. Damage at the stress fracture site and caudal diaphysis was reduced during all training programs for the turf and synthetic track surfaces with …
-
Equine proximal phalanx bone properties during growth
… density and bone area fraction in the distal, diaphysis, and proximal regions were evaluated. The diaphysis of the P1 maintained constant strain energy density (SED) during growth, indicating adaptation to the standing condition. The proximal region experienced the most changes in mineral …
-
Identification of Novel Cellular Pathways involved in Bone Mechanotransduction using Transcriptomics
… bone, inducing highest strains at the mid-diaphysis and lowest at the metaphyseal shell. We assessed load-induced gene expression in three cortical segments at early and late time points following tibial compression. The mid-diaphysis (highest strain) had the greatest transcriptomic …
-
Η ανάπτυξη και μελέτη ( κλινική και εμβιομηχανική) ενός νέου ενδομυελικού ήλου για την αντιμετώπιση των καταγμάτων της διάφυσης του βραχιονίου
… for the treatment of fractures of the humeral diaphysis. The nail is cannulated, square in shape – with concave sides – and has two different extensions that can be used with either the antegrade or the retrograde approach. Adequate rotational and axial stability is provided without the need …
-
Quantification of Skeletal Phenotype Using Micro-CT and Mechanical Testing
… femur, as well as cortical bone in the mid-diaphysis. After scanning, the femurs were tested to destruction in four-point bending at the mid-diaphysis about the medial lateral axis of the femur. These methodologies allowed quantification of (1) morphologic properties such as bone volume …
-
The Form and Function of the Pectoral Flipper in the Atlantic Bottlenose Dolphin (Tursiops truncatus)
… from the dorsal border of the scapula to the diaphysis of the humerus. From the brachium distally, tendons replace the intrinsic muscles resulting in an a muscular region distal from the diaphysis of the humerus. This tendon distribution represents a passive form system serving to restrain …
-
Characterizing strain in the proximal rat tibia during electrical muscle stimulation
… at the antero-medial aspect of the proximal diaphysis of tibia and plantar-flexor torque measured at the ankle during electrical muscle stimulation as an exercise countermeasure for hindlimb unloading in rats. A mathematical relationship between strain and torque was established for the …
-
Identifying the Origins of Bone Loss Induced by Transient Muscle Paralysis Using Novel MicroCT Image Registration Techniques
… quantified endocortical expansion in the tibial diaphysis following transient muscle paralysis using a novel microCT image registration approach. This approach identified a complex, but highly repeatable, resorptive response implicating osteoclast recruitment and focal activation of osteoclastic …
-
The Effects of Single- and Dual-Energy Quantitative Computed Tomography on Volumetric Bone Mineral Density Assessment and Strain Analysis in the Proximal Humerus
… calculated in the humeral head, metaphysis, and diaphysis regions, for each imaging modality. Image processing software was utilized to create 3D models of the humerus and highlighting the selected regions. Specimen-specific slope/intercept was used to convert from native Hounsfield Units (HU) to …
-
ΜΕΛΕΤΗ ΤΩΝ ΣΥΝΕΠΕΙΩΝ ΕΓΚΛΩΒΙΣΜΟΥ ΑΡΤΗΡΙΑΚΟΥ ΣΤΕΛΕΧΟΥΣ ΣΤΟΝ ΠΩΡΟ ΚΑΤΑΓΜΑΤΟΣ ΜΑΚΡΟΥ ΟΣΤΟΥ
… OF THE BRACHIAL ARTERY IN THE CALLUS OF THE DIAPHYSIS A FRAGMENTED BRACHIAL BONE. IT IS CONCLUDED THAT THE ENTRAPPED VESSELS IN THE CALLUS OF THEFRACTURES WHERE NO SEPTIC INFLAMMATION WAS EVIDENT, WERE NO STRANGULATED OR BLOCKED. BUT WHEN INFLAMMATION HAD DEVELOPED THE ENTRAPPED VESSELS …
-
Šlaunikaulio distalinės dalies lūžių nesugijimas: klinikinis atvejis ir literatūros apžvalga /
… The treatment lasted 8 years. Results: The diaphysis of the distal femur is characterized by poor vascularization and presents a risk of non-union in this area. The most common causes of non-union in distal femur fractures are improper or inadequate fixation, vascular damage and infection of …
-
Comparison of the Persisting Effects of Bisphosphonate Treatments Prior to Hindlimb Unloading on Mechanical and Densitometric Properties in the Tibia of Adult Male Rats
… at both the proximal metaphysis and the mid-diaphysis. The results of this study showed that bisphosphonates were able to prevent the bone loss that was seen in the HUC animals, and maintain bone at levels that were not statistically different from AC. Metaphysis pQCT scans showed that the …
-
Dual energy CT for more accurate diagnosis and monitoring of early osteoarthritis-related shoulder injuries
… humerus were assessed: the humeral shaft diaphysis, the articular surface of the humerus (humeral head), and the anatomical neck. Cadaveric scans were performed using both dipotassium phosphate (K2HPO4) and hydroxyapatite (HA) calibration phantoms while participants were scanned using only …
Page 1 of 5