Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 69 for “"Differential mobility analyzer"”
-
Tandem differential mobility analyzer studies and aerosol volatility
… which characterizes the performance of a Differential Mobility Analyzer (DMA) for diffusing particles; the first measurements of the transfer function for a specific type of cylindrical DMA used extensively at the University of Missouri-Rolla (UMR); and the application of a tandem DMA …
-
Measurement of coagulating silver and carbon aerosols using a tandem differential mobility analyzer
… and carbon ultrafine aerosols using a tandem differential mobility analyzer and an open flow coagulation chamber with a residence time of nearly 400 seconds. Results for both aerosols indicate that coagulation occurs faster than predicted by the model, at times differing by an order of …
-
The Role of Multi-Charged Responses: Construction and Application of a Tandem Differential Mobility Analyzer (TDMA)
… and the earth’s energy balance. Tandem Differential Mobility Analyzers (TDMAs) measure volatility and hygroscopicity by first selecting particles by size, then performing an experiment on the selected particles, and finally measuring the particles’ final diameter. For volatility, the …
-
Hygroscopicity measurements of atmospheric aerosol using a humidified tandem differential mobility analyzer (HTDMA) at a suburban site in Hong Kong
… <p>A new commercial Humidified Tandem Differential Mobility Analyzer (BMI HTDMA) was deployed for hygroscopicity measurements at the HKUST Air Quality Research Supersite. The performance of the system was first evaluated with respect to DMA sizing accuracy and resolution, detection of …
-
Mathematical modeling for instruments sizing and analyzing aerosols: operation of multiple monodisperse outlets differential mobility analyzer, volatility and hygroscopicity measurements analysis
… volatility and hygroscopicity) is by electrical mobility. With the advent of aerosol instrumentation, Differential Mobility Analyzers (DMAs) are the most commonly used instruments to classify or select particles within a narrow distribution of mobility diameter. When combining DMAs in series …
-
Parameterizing Climate-Relevant Properties of Biofuel and Biomass Particulate Emissions Based on Combustion Conditions
I also used a differential mobility analyzer to first determine the size distribution of the fresh aerosols. I then used a humidifying tandem differential mobility analyzer to determine the growth of fresh and aged aerosols under different humidity conditions (from 20% and 83% RH). Soot from wood …
-
Analýza hmotnosti a elektrické mobility iontů
… práce se zabývá rozborem metod měření elektrické mobility a hmotnosti iontů. V další části je konkrétně popsána měřicí aparatura Differential Mobility Analyzer-Mass Spectrometer, která se nachází v laboratoři Keck Facility na Yale University v USA, a jsou analyzovány iontové kapaliny IL A, IL B a …
-
Charge Distribution Inversion for Supermicrometer Particles via Differential Mobility Analysis and Optical Particle Spectrometry
… charge state distributions, such as the Tandem Differential Mobility Analyzer approach, they are generally applied only for low charge, submicrometer particles. The method proposed here combines a Differential Mobility Analyzer (DMA) with a laser-based optical particle spectrometer capable of …
-
Isolation of ambient aerosols of known critical supersaturation: the differential critical supersaturation separator (DSCS)
… Sc, within a narrow, user-specified, range. This Differential Critical Supersaturation Separator (DScS) is designed to supply one or more particle size and/or composition analyzers to permit the direct examination of the factors that influence the activation properties of ambient aerosols. The …
-
The Evolution of the Physicochemical Properties of Aerosols in the Atmosphere
A Differential Mobility Analyzer/Tandem Differential Mobility Analyzer (DMA/TDMA) system was used to measure simultaneously the size distribution and hygroscopicity of the ambient aerosol population. The system was operated aboard the National Center for Atmospheric Research/National Science …
-
Variation in Morphology, Hygroscopicity, and Optical Properties of Soot Particles Coated by Dicarboxylic Acids
… promote water uptake. In this study, the tandem differential mobility analyzer (TDMA) and differential mobility analyzer?aerosol particle mass analyzer (DMA?APM) were employed to measure the changes in morphology and hygroscopicity of soot aerosol particles upon coating with succinic and glutaric …
-
Investigation of the optical and cloud forming properties of pollution, biomass burning, and mineral dust aerosols
… The tool used for most of these analyses is a differential mobility analyzer / tandem differential mobility analyzer (DMA / TDMA) system developed in our research group. To collect the data described in two of the chapters of this dissertation, an aircraft-based version of the DMA / TDMA was …
-
Developing models of aerosol representation to investigate composition, evolution, optical properties, and CCN spectra using measurements of size-resolved hygroscopicity
A Differential Mobility Analyzer/Tandem Differential Mobility Analyzer (DMA/TDMA) was used to measure size distributions, hygroscopicity, and volatility during the May 2003 Aerosol Intensive Operational Period at the Central Facility of the Atmospheric Radiation Measurement Southern Great Plains …
-
Restructuring of soot particles by surface coatings
… effective density, mass concentration and mass-mobility exponent of particles from an inverted burner and a McKenna burner were measured with a Differential Mobility Analyzer (DMA) and a Centrifugal Particle Mass Analyzer (CPMA). Based on these properties a recommendation was made to choose an …
-
Measurements of the Size Distribution and Aerodynamic Properties of Soot
… are confirmed with a diffusion battery and a differential mobility analyzer. Size distribution measurements of soot agglomerates have been obtained from optical and electron microscopy for a range of acetylene flow rates. The electron microscopy results are compared to model predictions of the …
-
Characterization of Nanoparticle Soot Size Distribution from an Aero-Derivative Combustor by use of Half-Mini DMA
… size distributions utilizing a state-of-the-art differential mobility analyzer (DMA, Half-Mini #p model) at a variety of operating conditions. Methodologies, design alterations, and results are proposed for global equivalence ratios between 0.1-0.2 and combustion pressures between 35-85 psi. The …
-
Investigation of Chlorinated Silicon Nanoparticles and In situ Analysis of the Size Distribution of Plasma Produced Particles
… precursor used during synthesis. A low pressure differential mobility analyzer (LPDMA) was installed downstream of a silicon nanocrystal plasma reactor in order to take in situ measurements of particle size distributions. Roughly equal amounts of positive and negative particles are observed. Size …
-
Aerodynamic Aerosol Classifier
… particles and DOS (DioctylSebacate) along with a differential mobility analyzer (DMA) were used to verify the instrument and to obtain the experimental transfer function. A DMA and the AAC were used in tandem to measure the effective density, dynamic shape factor, and the mass of soot particles …
-
The seasonality of aerosol properties in Big Bend National Park
… winter of 2004 were conducted utilizing a tandem differential mobility analyzer (TDMA) and, during the spring and summer, an aerodynamic particle sizer (APS), to characterize the seasonal variability of the Big Bend regions aerosol optical properties. Mass extinction efficiencies and relative …
-
Instrument Artifacts Lead to Uncertainties in Parameterizations of Cloud Condensation Nucleation
… of three instruments: the CCN instrument, the differential mobility analyzer (DMA), and the condensation particle counter (CPC). Assessment of DMA operation showed that varying the ratio of aerosol to sheath flow from 0.05 to 0.30 resulted in discrepancies between the kvapp values calculated …
Page 1 of 4