Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 19 of 19 for “"Differential relay"”.

  1. A direct current differential relay

    … be greater than that in the other. This current differential can be made to operate a direct current differential relay. About the two supplying leads, when such a fault occurs, will exist a magnetomotive force. This mmf will set up a flux in the core and armature of a relay which forms a …

    vt Repository record for A direct current differential relay (opens in a new tab)

  2. A DIGITAL TRANSFORMER DIFFERENTIAL AND RESTRICTED EARTH FAULT RELAY

    Many kinds of relays are used to detect faults in power transformers. Two of these relays are the restricted earth fault and transformer differential relays. The concepts of harmonic restraint and variable percentage of differential characteristic have been widely used in the conventional …

    sask Repository record for A DIGITAL TRANSFORMER DIFFERENTIAL AND RESTRICTED EARTH FAULT RELAY (opens in a new tab)

  3. Fault Discrimination Algorithm for Busbar Differential Protection Relaying Using Partial Operating Current Characteristics

    Differential protection is the unit protection system which is applied to protect a particular unit of power systems. Unit is known as zone in protection terminology which is equivalent to simple electrical node. In recent time, low impedance current differential protection schemes based on …

    uno Repository record for Fault Discrimination Algorithm for Busbar Differential Protection Relaying Using Partial Operating Current Characteristics (opens in a new tab)

  4. The application of artificial neural networks to transformer protection

    … provides inrush or no-inrush indication to the differential relay. Some important issues such as the neural network's and the simulated sample power network's structures; simulation, selection and preprocess of the sample data are discussed. The A NN is trained and tested by using simulated data …

    ubc Repository record for The application of artificial neural networks to transformer protection (opens in a new tab) Download PDF for The application of artificial neural networks to transformer protection (opens in a new tab)

  5. INSTRUMENTATION CHANNEL ERROR CORRECTION AND ITS EFFECTS ON PROTECTIVE RELAYS

    … and to investigate its effects on protective relays. The physically-based high fidelity models of entire instrumentation channel are developed, which consist of the instrument transformer, the instrumentation cable and the burden resistor. A dynamic state estimation algorithm is constructed to …

    gatech Repository record for INSTRUMENTATION CHANNEL ERROR CORRECTION AND ITS EFFECTS ON PROTECTIVE RELAYS (opens in a new tab)

  6. Transient Simulations of Power Systems with Inverter Interfaced Resources

    … aims to improve the performance of protective relays during faults. Several challenges with protective relays' inability to detect faults are attributed to such energy sources. The EMTP-ATP simulation package is used to develop the simulation model with the fault response benchmarked from the …

    mtu Repository record for Transient Simulations of Power Systems with Inverter Interfaced Resources (opens in a new tab)

  7. Impact of MHD-E3 on power system equipment and loads.

    … levels of harmonics on power system protective relays, and the impact of harmonic-rich voltages on information technology equipment. A benchtop transformer DC injection testing apparatus was designed and constructed, and these laboratory transformer test results are analyzed and compared with …

    baylor Repository record for Impact of MHD-E3 on power system equipment and loads. (opens in a new tab)

  8. Development and simulation of DSP filters for transformer differential protection / by Oskar Reynisson.

    … applications within the power system protective relay field. Transformers with a capacity rating exceeding 10 MVA are usually protected using differential current relays. Transformers are an aging and vulnerable bottleneck in the present power grid; therefore, quick fault detection and …

    mtu Repository record for Development and simulation of DSP filters for transformer differential protection / by Oskar Reynisson. (opens in a new tab)

  9. Ratios-Based Universal Differential Protection Scheme for Power Transformers

    … in power transformer protection. Percentage differential relay is reportedly the most commonly used approach to protect transformers rated from 10 MVA and above. However, it is known that the conventional differential protection could mal-operate owing to the characteristics associated with …

    calgary Repository record for Ratios-Based Universal Differential Protection Scheme for Power Transformers (opens in a new tab)

  10. Design and Implementation of Overcurrent Protection Relays Test Bench

    … electromechanical and microprocessor protection relays, manual isolation and industrial circuit breakers, switches, variable autotransformer (VARIAC), voltmeters and ammeters. During the dismantling, a lot of equipment was retrieved for future possible use. This led to the idea of designing and …

    wvu Repository record for Design and Implementation of Overcurrent Protection Relays Test Bench (opens in a new tab)

  11. Transformer Differential Protection Under Geomagnetically Induced Current Conditions

    … for protection systems, such as transformer differential relays. The majority of real-world transformer differential relays employ harmonic blocking (HB) modules to prevent malfunctions during transformer energization leading to inrush currents containing high levels of second harmonics. …

    york Repository record for Transformer Differential Protection Under Geomagnetically Induced Current Conditions (opens in a new tab)

  12. Remote Monitoring and Control of Protection Relays via Programmable Logic Controller

    … wirelessly monitor and control power protection relays. The technologies surrounding power protection and industrial automation are ever evolving and have developed significantly in recent history. Industrial power applications call for consistent condition monitoring and status updates for …

    calpoly Repository record for Remote Monitoring and Control of Protection Relays via Programmable Logic Controller (opens in a new tab)

  13. Modeling relays for power system protection studies

    Numerical relays are the result of the application of microprocessor technology in relay industry. Numerical relays have the ability to communicate with its peers, are economical and are easy to operate, adjust and repair. Modeling of digital and numerical relays is important to adjust and settle …

    sask Repository record for Modeling relays for power system protection studies (opens in a new tab)

  14. Detection of Inter-turn Winding Fault in Single-phase Transformers Using a Terminal Measurement Based Modeling Technique

    … faults often go undetected by the traditional differential relay based protection mechanisms. By the time, the faults manifest themselves into severe winding short-circuit faults consequently forcing the differential relays to operate for tripping the circuit breakers; a significant part of the …

    uvic Repository record for Detection of Inter-turn Winding Fault in Single-phase Transformers Using a Terminal Measurement Based Modeling Technique (opens in a new tab)

  15. Protection system lab experiments with overcurrent and differential relays

    … protection schemes, overcurrent protection and differential current protection, with the design of experiments and exercises for electrical engineering students. The objective of this undertaking is educational, so that students can learn, understand, and execute various operations pertaining to …

    texas Repository record for Protection system lab experiments with overcurrent and differential relays (opens in a new tab)

  16. Hardware-in-the-Loop Prototype of a Negative Sequence Based Scheme for Turn-to-Turn Fault Detection in Transformers

    … damaging the transformer beyond repair. Current differential transformer protection is a simple, reliable, and cost effect method of detecting turn-to-turn faults. This method of protection is only able to detect faults involving 10% of the windings or more. The sensitivity of current …

    sask Repository record for Hardware-in-the-Loop Prototype of a Negative Sequence Based Scheme for Turn-to-Turn Fault Detection in Transformers (opens in a new tab)

  17. Application-Based Measures for Developing Cyber-Resilient Control and Protection Schemes in Power Networks

    … networks by unveiling a vulnerable protective relay, i.e., the LCDR, and a susceptible controller, i.e., the AGC system, and proposing application-based measures for making them resilient against cyber threats. LCDRs are a group of protective relays that are highly dependent on communication …

    waterloo Repository record for Application-Based Measures for Developing Cyber-Resilient Control and Protection Schemes in Power Networks (opens in a new tab)

  18. Testování ochrany transformátoru

    Cílem bakalářské práce bylo chránění transformátoru, konkrétně pak rozdílová ochrana transformátoru, její princip funkce, stabilizace a vypínací charakteristika. Byl navrhnut způsob měření vypínací charakteristiky ochrany SPAD 346 C od firmy ABB. K měření bylo použito testovací zařízení TZO3, které …

    brno-tech Repository record for Testování ochrany transformátoru (opens in a new tab)