Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 22 for “"Digital Impression"”.
-
Time efficiency of digital impression systems
… evaluate the time efficiency of computer aided impression making procedure among various digital intraoral scanning systems. Furthermore, a comparison of time efficiency between the digital and conventional impression making method was conducted. Three different intraoral scanners (iTero, LAVA …
-
Accuracy of various intraoral digital impression techniques
… scanning devices by comparing digitized dental impressions of teeth prepared for full dental arch fixed restorations. A basic study model (Kavo®, Biberach, Germany) with 14 prepared abutments was replicated using a polyurethane material and was used as the reference model (RM). The reference …
-
Accuracy of Three Digital Impression Techniques for Implant-Fixed Complete Dentures
… of implant-fixed complete denture (IFCD) impression techniques is unclear. The purpose of this in vitro study was to compare the accuracy of three digital impression techniques for IFCD. A polyurethane edentulous mandible with four implant analogs served as the master model. A reference …
-
Reliability of Full-Arch Tooth-Supported Digital Impression and Accuracy of Selective Rescanning of Finish Line Under Lock Area Feature
… cast poured from polyvinyl siloxane (PVS) impressions for full-arch preparations, and to evaluate the effect of selective rescanning using the Lock Area function within a single scanner and software workflow. Methods: This in vitro study used a maxillary typodont prepared to simulate a full …
-
Effect of Different Scanning Techniques and Implant Abutment Angulations on the Accuracy of Intraoral Full-Arch Abutment Level Digital Impression for Mandibular Full-Arch Implant-Supported Fixed Prostheses
… on the accuracy of completely edentulous arch digital impression is lacking. Purpose. The purpose of this in vitro study was to evaluate the effect of four different scanning techniques and three different abutment angulations on the accuracy of intra-oral scanning of fully edentulous mandible. …
-
Comparison of marginal fit of lithium disilicate crowns fabricated with CAD-CAM technology using conventional impressions and two intra-oral digital scanners.
The use of digital impression techniques in dental crown fabrication is increasing. It is important these techniques yield prosthesis of equal or better accuracy compared to conventional techniques. This study compared marginal gap size in crowns fabricated by conventional and digital impression …
-
Marginal fit of lithium disilicate crowns : a three-dimensional analysis
… lithium disilicate (LDS) crowns fabricated with digital impression and manufacturing (termed “DD”), digital impression and traditional pressed manufacturing (termed “DP”), and traditional impression and manufacturing (termed “TP”). Methods: Tooth #15 was prepared for all-ceramic crowns on an …
-
The effect of crown cementation on the marginal fit using a micro-CT measurement technique
… gap of lithium disilicate (LDS) crowns made with digital impression and manufacturing (DD), digital impression and traditional pressed manufacturing (DP) and traditional impression and manufacturing (TP). Methods: Ivorine typodont tooth #15 was prepared for an all-ceramic crown. The prepared tooth …
-
"Performing Professionalism" The Communicative Strategies of Nigerian Women in Global Remote Teams
This study explores the digital intercultural communication experiences of Nigerian Women Remote Workers (NWRWs) in remote workspaces. It analyzes how culture, gender, language, and technology converge to influence workplace interactions. Data were collected through semi-structured interviews with …
-
In Vitro Comparative Study Between Full-Arch Conventional Implant Impressions and Full-Arch Digital Implant Impressions with Snap-on Scan Bodies
Statement of Problem: Digital impression techniques are widely used in everyday cases. There is sufficient evidence to support this technique in partially edentulous patients but the evidence supporting the use of intraoral scanners (IOS) in restorative digital workflows for edentulous patients is …
-
Effect of impression technique, connection type and implant angulation on accuracy of implant impressions for edentulous patients
… was to compare the accuracy of conventional and digital impression techniques for completely edentulous patients.Materials and Methods: An edentulous mandibular cast with 5 implants was fabricated to serve as control cast at both implant and abutment-level. The 3 median implants were parallel, …
-
Evaluation of the marginal fit of single-unit, complete-coverage ceramic restorations fabricated after digital and conventional impressions: a systematic review and meta-analysis
… some studies indicate the superiority of digital impression systems in terms of the marginal accuracy of ceramic restorations, whereas others show that the conventional method provides restorations with better marginal fit than fully digital fabrication. Which impression method provides …
-
Performance in a digital world : Navigating commercial drama in WeChat blogs
… and advertisers, generating commercially driven digital performance that meet the expectations of both sides? How marketers analyse criteria when selecting influencers and assess their cooperation to acquire valuable information that may enhance their digital performance? What challenges and …
-
The use of CAD CAM For Fixed Partial Prostheses
… of three unit all zirconia bridges produced by digital and conventional techniques.<br/><br/>For these laboratory studies an ideal three unit (and four unit for study 3) fixed-fixed all ceramic bridge preparation was carried out on two plastic teeth and all SLA models and zirconia based bridges …
-
Dental implants' acquisition system for personalized dental prosthesis
… thus opens the way for a fully user independent, digital impression workflow.
-
Comparison of digital scanning and polyvinyl siloxane impression techniques by DMD students : instructional efficiency and attitudes toward technology.
… the ability of dental students to learn an digital scanner (3M LAVA) and material-based (PVS) impression techniques and to determine attitudes and preferences towards each. D2 dental students (n=25) were recruited and instructed on the use of 3M LAVA and PVS techniques using three pedagogic …
-
Genauigkeit von Ganzkieferscans mit Intraoralscannern im Vergleich zu indirekten Digitalisierungsmethoden
… Überblick über die Genauigkeit der intraoralen Digitalisierung des ganzen Zahnbogens zu geben. Darüber hinaus sollte die Methode der direkten Digitalisierung mit den verschiedenen Möglichkeiten zur indirekten Digitalisierung von Patientenmodellen für die kieferorthopädische Behandlung verglichen …
-
Capacity Of The 3M True Definition Scanner To Make Repeatable Impressions Depending On Placement Of Margins In Relation To Gingival Height.
… the infra-gingival groups. Conclusion: Optical impressions using the TDS was determined to be reliable in producing precise impressions scans with supra-gingival and equi-gingival margins. However, as the position of the margin was located more infra-gingival, the scans become incomplete and …
-
Scangenauigkeit eines einteiligen Zirkoniumdioxid-Implantats ohne Scanbody
… (ZI) könnten eine direkte digitale Abformung ohne Scanbody ermöglichen. Ziel dieser Studie war es daher die Genauigkeit von Intraoralscans von ZI mit Einzelzahnpräparationen (EP) und zweiteiligen Titan-Implantaten mit Scanbody (TI) zu vergleichen. Weiterhin sollte untersucht …
-
Einfluss unterschiedlicher Modellmaterialien auf die Dimensionsstabilität, Scan-Eignung und Abriebfestigkeit im CAD/CAM-Herstellungsprozess mehrgliedriger Brücken
Ziel: Seit Einführung der digitalen Abformungen in den computer-aided design (CAD)/ computer-aided manufacturing (CAM)-Workflow besteht großes Interesse an Untersuchungen zur Passgenauigkeit der damit gefertigten Restaurationen sowie der Genauigkeit von Intraoralscannern. Modelle für derartige …
Page 1 of 2