Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 72 for “"Digital Particle Image Velocimetry"”.

  1. Time-Resolved Analysis of Circulation Control over Supercritical Airfoil using Digital Particle Image Velocimetry (DPIV)

    Active pneumatic flow control methods as applied to aerospace applications have shown noteworthy improvements in lift compared to traditional means. The General Aviation Circulation Control (GACC) concept currently under investigation at NASA's Langley Research Center (LaRC) is an attempt at …

    vt Repository record for Time-Resolved Analysis of Circulation Control over Supercritical Airfoil using Digital Particle Image Velocimetry (DPIV) (opens in a new tab)

  2. A Hybrid Dynamically Adaptive, Super-Spatio Temporal Resolution Digital Particle Image Velocimetry for Multi-Phase Flows

    A unique, super spatio-temporal resolution Digital Particle Image Velocimetry (DPIV) system with capability of resolving velocities in a multi-phase flow field, using a very sophisticated novel Dynamically Adaptive Hybrid velocity evaluation algorithm has been developed The unique methodology of …

    vt Repository record for A Hybrid Dynamically Adaptive, Super-Spatio Temporal Resolution Digital Particle Image Velocimetry for Multi-Phase Flows (opens in a new tab)

  3. Experiments on transient natural convection in inclined enclosures using calibrated multichannel electronic interferometry and digital particle image velocimetry

    … and the velocity is measured using digital particle image velocimetry. This allows accurate measurement of the temperature and velocity fields throughout the enclosure and visualization of the boundary layers, intrusion layers, and recirculation zones. The angle of inclination is …

    unh-thes Repository record for Experiments on transient natural convection in inclined enclosures using calibrated multichannel electronic interferometry and digital particle image velocimetry (opens in a new tab)

  4. Hemodynamic Flow Characterization of St. Jude Medical Bileaflet Mechanical and Bioprosthetic Heart Valve Prostheses in a Left Ventricular Model via Digital Particle Image Velocimetry

    … most of which were obtained by Laser Doppler Velocimetry (LDV) in rigid models of the aorta. Digital Particle Image Velocimetry (DPIV) has also been utilized to reveal intricate patterns of interacting shed vortices downstream of the aortic valve. The orientation of the valves may considerably …

    vt Repository record for Hemodynamic Flow Characterization of St. Jude Medical Bileaflet Mechanical and Bioprosthetic Heart Valve Prostheses in a Left Ventricular Model via Digital Particle Image Velocimetry (opens in a new tab)

  5. Experimental investigation of the fluid dynamic aspects of a bileaflet mechanical heart valve

    … mechanical heart valve is investigated using digital particle image velocimetry. Evolution of flow structures during the systole and diastole phases of a typical cardiac cycle is characterized by obtaining global flow velocity measurements in multiple cross-sections of the flow field. …

    uvic Repository record for Experimental investigation of the fluid dynamic aspects of a bileaflet mechanical heart valve (opens in a new tab)

  6. Multiphase Hydrodynamics in Flotation Systems

    … turbulence experiment was conducted to verify particle collision models. The slip velocities of solid particles and bubbles were measured using Digital Particle Image Velocimetry (DPIV). The experimental results were compared with the predictions from empirical and theoretical collision models. …

    vt Repository record for Multiphase Hydrodynamics in Flotation Systems (opens in a new tab)

  7. Analysis of near-surface flow measurements beneath clean and contaminated wind-driven water surfaces

    … velocity fields were measured using digital particle image velocimetry (DPIV) and water surface temperature measurements were made simultaneously using infrared imagery. Results are reported for two wind speeds, 6.3 and 8.1 m s -1 . (Abstract shortened by UMI.)

    concordia Download PDF for Analysis of near-surface flow measurements beneath clean and contaminated wind-driven water surfaces (opens in a new tab)

  8. Aerodynamics of a Heaving and pitching aerofoil

    … at low Reynolds numbers. Two dimensional Digital Particle Image Velocimetry (DPIV) was used to study the unsteady flows of a simplified flapping foil model, that of a heaving and pitching elliptical aerofoil. The aerofoil was subjected to a uniform free stream in a water tunnel with a …

    nus Repository record for Aerodynamics of a Heaving and pitching aerofoil (opens in a new tab) Download file for Aerodynamics of a Heaving and pitching aerofoil (opens in a new tab)

  9. Investigations of acoustically-coupled shear layers using particle image velocimetry

    Digital particle image velocimetry is employed to investigate acoustically-coupled flow past a coaxial deep cavity (side branch) resonator mounted in a duct. The emphasis is on the effect of the separation between the coaxial side branches on the interaction between separated shear layers that form …

    uvic Repository record for Investigations of acoustically-coupled shear layers using particle image velocimetry (opens in a new tab)

  10. An experimental investigation of vortex breakdown in tubes at high reynolds numbers

    … video, short exposure time (6 ns) imaging, and Digital Particle Image Velocimetry. Of the known types, the spiral emerges as the fundamental breakdown form and the axisymmetric bubble may now be regarded as a relatively low Re(D) occurrence that is bypassed at sufficiently high Re(D). Some new …

    nps Repository record for An experimental investigation of vortex breakdown in tubes at high reynolds numbers (opens in a new tab)

  11. Experimental investigation of bio inspired flapping wings for MAV and NAV applications

    … configuration were carried out with the help of Digital Particle Image Velocimetry (DPIV) by which quantitative flow field measurements were made. The PIV results provide a greater understanding of the vortex structures which were generated due to high frequency flapping motion of the wings.</p>

    iastate Repository record for Experimental investigation of bio inspired flapping wings for MAV and NAV applications (opens in a new tab)

  12. The contribution of the pectoral fins, body, and the ribbon fin to turning maneuvers of a gymnotiform swimmer

    … contributed to both small and large turns. Digital particle image velocimetry (DPIV) showed that the ribbon fin generates larger counter rotating vortices during turning than is produced during steady swimming. All three control surfaces contributed to steady swimming and large turns while …

    kennesaw Repository record for The contribution of the pectoral fins, body, and the ribbon fin to turning maneuvers of a gymnotiform swimmer (opens in a new tab)

  13. Experimental Investigations into Shark Skin Inspired Active Flow Control Mechanisms

    … scales was studied experimentally using digital particle image velocimetry (DPIV).The flaps in this study had a rectangular shape and were designed with a protrusion heightin the bottom 10% of the boundary layer height, which is similar to that of the flexiblescales found on the mako …

    alabama Repository record for Experimental Investigations into Shark Skin Inspired Active Flow Control Mechanisms (opens in a new tab)

  14. BENTHIC WALKING, CRYPTIC LOCOMOTION, AND EVOLUTIONARY MORPHOLOGY OF BODY FORM IN FLATFISHES (PLEURONECTIFORMES)

    … speeds while maintaining a low profile. Using Digital Particle Image Velocimetry (Chapter 3) I measured the velocity magnitude and vorticity of water flow around walking and swimming flatfishes. I found that water disturbance was much lower during walking, without the trailing vortices produced …

    cornell Repository record for BENTHIC WALKING, CRYPTIC LOCOMOTION, AND EVOLUTIONARY MORPHOLOGY OF BODY FORM IN FLATFISHES (PLEURONECTIFORMES) (opens in a new tab)

  15. Left Ventricular Flow Patterns after Percutaneous Edge-to-Edge Mitral Valve Repair: An in vitro Study

    … method, Phase Locked and Time Resolved Digital Particle Image Velocimetry inside the LV. A custom-made mitral valve was developed and two configurations were tested: a single orifice valve with mitral regurgitation and a double-orifice mitral valve configuration. The hemodynamic …

    concordia Download PDF for Left Ventricular Flow Patterns after Percutaneous Edge-to-Edge Mitral Valve Repair: An in vitro Study (opens in a new tab)

  16. Experimental Investigation of the Effects of a Passing Shock on Compressor Stator Flow

    … investigated using shadowgraph photography and Digital Particle Image Velocimetry (DPIV). Measurements were taken for three different shock strengths. In every case studied, a vortex formed near the stator trailing edge as the shock impacted the blade. The size of this vortex was shown to be …

    vt Repository record for Experimental Investigation of the Effects of a Passing Shock on Compressor Stator Flow (opens in a new tab)

  17. Development of Robust Correlation Algorithms for Image Velocimetry using Advanced Filtering

    Digital Particle Image Velocimetry (DPIV) is a planar measurement technique to measure the velocity within a fluid by correlating the motion of flow tracers over a sequence of images recorded with a camera-laser system. Sophisticated digital processing algorithms are required to provide a high …

    vt Repository record for Development of Robust Correlation Algorithms for Image Velocimetry using Advanced Filtering (opens in a new tab)

  18. The effect of butterfly-scale inspired patterning on leading-edge vortex growth

    … at Rec = 1416, 2833, and 5667 are examined using Digital Particle Image Velocimetry (DPIV). The maximum vortex formation number is 2.8 and is based on the flat plate travel length and chord length. Flow fields from each case show the generation of a secondary vortex whose interaction with the …

    alabama Repository record for The effect of butterfly-scale inspired patterning on leading-edge vortex growth (opens in a new tab)

  19. Drag measurements across patterned surfaces in a low Reynolds number Couette flow facility

    … flow with a linear velocity profile was created. Digital particle image velocimetry was used to confirm the velocity profile. A patterned surface, in this case consisting of 2-D cavities, was embedded into a large portion of a Plexiglas plate. First, the drag across a flat plate of the same size …

    alabama Repository record for Drag measurements across patterned surfaces in a low Reynolds number Couette flow facility (opens in a new tab)

  20. Turbulent separation control effects of mako shark skin samples on a naca 4412 hydrofoil

    … in this study were obtained using Time-Resolved Digital Particle Image Velocimetry and recorded at multiple angles of attack (between 8 and 16 degrees) and two Reynolds numbers. The flow was primarily analyzed by means of the backflow coefficient (a value based on the percentage of time that flow …

    alabama Repository record for Turbulent separation control effects of mako shark skin samples on a naca 4412 hydrofoil (opens in a new tab)

Page 1 of 4