Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 968 for “"Digital image correlation"”.

  1. QUANTIFYING J-R CURVE USING DIGITAL IMAGE CORRELATION

    This thesis presents a non-contact digital image correlation (DIC) approach to measure the J-integral resistance (J-R) curve under quasi-static and dynamic loadings. The DIC-based J quantification deploys specified contours and domains while the amount of crack extension derives from the …

    nus Repository record for QUANTIFYING J-R CURVE USING DIGITAL IMAGE CORRELATION (opens in a new tab) Download file for QUANTIFYING J-R CURVE USING DIGITAL IMAGE CORRELATION (opens in a new tab)

  2. Three Dimensional Digital Image Correlation for Dynamic Measurements

    … access to the structure and minimal cabling. Digital Image Correlation (DIC) is a photogrammetry technique that involves tracking multiple subsets through a series of images to determine full field displacements. DIC can take the form of 2D DIC using one camera or 3D DIC using more than one …

    waterloo Repository record for Three Dimensional Digital Image Correlation for Dynamic Measurements (opens in a new tab)

  3. Digital Image Correlation for Evaluating Structural Engineering Materials

    … models. Recent advances have enabled the use of digital image correlation (DIC) to calculate the surface displacements of chosen targets in a series of digital images with a high degree of accuracy. Images are recorded during an experiment and are afterwards post-processed to find relevant …

    queens Repository record for Digital Image Correlation for Evaluating Structural Engineering Materials (opens in a new tab)

  4. Full Blade Digital Image Correlation (DIC) Test Apparatus

    The objective of this study was to design a Digital Image Correlation (DIC) apparatuscapable of measuring sectional stiffness properties of full scale helicopter blades within preexisting facilities. To do so, this study expanded on previous studies findings that deemed DIC apparatus as an ideal …

    maryland Repository record for Full Blade Digital Image Correlation (DIC) Test Apparatus (opens in a new tab)

  5. Finite Element Model Calibration with Digital Image Correlation

    … material models in the FE modelling increases. Digital Image Correlation(DIC) is a non-contact measurement technique used to measure displacements and strains locally on a surface in space and time. The goal of this thesis is to use DIC data to calibrate some typical material models used in FE …

    chalmers Repository record for Finite Element Model Calibration with Digital Image Correlation (opens in a new tab)

  6. Characterisation of Polymeric Foam Cores Using Digital Image Correlation

    … obtained; full eld deformation measurement using digital image correlation (DIC) presents a potential means of achieving this. The overall aim of this work is to determine if DIC based full eld strain measurement techniques can be used to achieve more accurate constitutive characterisation of …

    auckland-ms Repository record for Characterisation of Polymeric Foam Cores Using Digital Image Correlation (opens in a new tab)

  7. Monitoring of Dynamic Bridge Behaviour Using Digital Image Correlation

    … to supplement inspections is needed. Digital Image Correlation (DIC) is a novel monitoring technology that uses digital images to measure displacement fields without any contact with the bridge. In this research, DIC and accelerometers were used to investigate the dynamic response of a …

    queens Repository record for Monitoring of Dynamic Bridge Behaviour Using Digital Image Correlation (opens in a new tab)

  8. Deformation mapping of fibronectin fibrils using digital image correlation

    … cells. This study has developed an automated Digital Image Correlation based technique for determining the displacements and strains experienced by the fibrils during the assembly process. Fibril motion is tracked using a time lapse sequence of images and the motion kinematics are determined …

    umkc Repository record for Deformation mapping of fibronectin fibrils using digital image correlation (opens in a new tab)

  9. Development of Crack Characterization Methodology Using Digital Image Correlation

    … region of interest. This paper presents a digital image correlation-based methodology developed from in-plane compact fracture specimens for the detection and quantification of fatigue cracks. The effectiveness of the proposed methodology is further evaluated through experimental tests of a …

    ku Repository record for Development of Crack Characterization Methodology Using Digital Image Correlation (opens in a new tab)

  10. Measurement of deformation of rotating blades using digital image correlation

    An experimental study on the application of Digital Image Correlation (DIC) to measure the deformation and strain of rotating blades is described. Commercial DIC software was used to obtain measurements on three different types of rotors with diameter ranging from 18 to 39 and with varying …

    texas Repository record for Measurement of deformation of rotating blades using digital image correlation (opens in a new tab)

  11. 3-D Digital Image Correlation using a single color-camera

    Digital Image Correlation (DIC) is an optical and numerical method capable of accurately providing full-field, two-dimensional (2-D) and three-dimensional (3-D) surface displacements and strains. 3-D DIC is typically done using two cameras that view the measured object from differing oblique …

    ubc Repository record for 3-D Digital Image Correlation using a single color-camera (opens in a new tab) Download PDF for 3-D Digital Image Correlation using a single color-camera (opens in a new tab)

  12. Enhancing the robustness of ESPI measurements using digital image correlation

    … of the speckle phase angles within surface images measured before and after material deformation. This phase angle comparison requires that the speckle positions be consistent in all images. A lateral shift between images by just one pixel substantially degrades ESPI measurements, while a …

    ubc Repository record for Enhancing the robustness of ESPI measurements using digital image correlation (opens in a new tab) Download PDF for Enhancing the robustness of ESPI measurements using digital image correlation (opens in a new tab)

  13. Validation of immature ovine bone models using digital image correlation

    … bones, by comparing strain results against 3D digital image correlation (3D-DIC) data during four-point bending tests. In this thesis, two experimental set-ups were designed to run four-point bending tests on lamb femur specimens using 3D-DIC to capture full-field surface strain. The first set …

    whiterose Download PDF for Validation of immature ovine bone models using digital image correlation (opens in a new tab)

  14. Quantifying Renal Swelling during Machine Perfusion using Digital Image Correlation

    … An experimental methodology was developed to image porcine kidneys undergoing hypothermic machine perfusion (5 deg C) for 15 minutes followed by 120 minutes without perfusion to quantify surface displacement (renal swelling) with digital image correlation (DIC). Surface displacement and size …

    vt Repository record for Quantifying Renal Swelling during Machine Perfusion using Digital Image Correlation (opens in a new tab)

  15. In-Situ Monitoring of Additive Manufacturing Using Digital Image Correlation

    … In this research, an in-situ approach using Digital Image Correlation (DIC) is developed to monitor the deformation during the processing, and thereby analyze the formation of defects and residual stresses. DIC is a visual technique that compares the changes in speckle pattern in consecutive …

    embry-riddle Repository record for In-Situ Monitoring of Additive Manufacturing Using Digital Image Correlation (opens in a new tab)

  16. Development of digital image correlation method for displacement and shape measurement

    In this thesis, the method of digital image correlation, which is conventionally used for in-plane displacement measurement, is further developed for out-of-plane displacement and shape measurement using a single camera. In addition, digital image correlation method is also combined with fringe …

    nus Repository record for Development of digital image correlation method for displacement and shape measurement (opens in a new tab) Download file for Development of digital image correlation method for displacement and shape measurement (opens in a new tab)

  17. Dynamic Monitoring of Rail and Bridge Displacements Using Digital Image Correlation

    … of ensuring this efficient and safe operation. Digital Image Correlation (DIC) is a monitoring technology that has the potential to provide critical data for infrastructure assessment and to replace various conventional sensors with one integrated monitoring solution. In this research, the …

    queens Repository record for Dynamic Monitoring of Rail and Bridge Displacements Using Digital Image Correlation (opens in a new tab)

Page 1 of 49