Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 22 for “"Digital measurements"”.

  1. Soil Moisture and Light Conditions Impact Digital and Visual Soil Color Assessments

    … water content (SWC) and light intensity. New digital spectral technology designed for determining soil color may offer accurate assessments regardless of human inaccuracies and environmental conditions. This research aimed to assess if visual observations differed from digital measurements of …

    clemson Repository record for Soil Moisture and Light Conditions Impact Digital and Visual Soil Color Assessments (opens in a new tab)

  2. Accuracy and Reproducibility of Cone Beam Computed Tomographs for The Assessment of Bony Tissues, An ex-vivo study

    … softwares were used for measurement. Actual and digital measurements were compared to determine device-specific errors. The repositioned skull scans were used to determine reproducibility of the CBCT devices. The peri-implant buccal bone thickness was measured to evaluate the impact of implants …

    loma-linda Repository record for Accuracy and Reproducibility of Cone Beam Computed Tomographs for The Assessment of Bony Tissues, An ex-vivo study (opens in a new tab)

  3. EVALUATING THE ACCURACY OF STATURE ESTIMATION FROM TIBIAL RADIOGRAPHS USING KNOWN AND NEWLY DEVELOPED REGRESSION FORMULAS

    … stature estimation from tibial radiographs using digital measurements as an alternative to traditional osteometric tools. Stature estimation is crucial in forensic anthropology for identifying individuals, especially cases involving skeletal remains. Traditional methods rely on physical …

    montana Repository record for EVALUATING THE ACCURACY OF STATURE ESTIMATION FROM TIBIAL RADIOGRAPHS USING KNOWN AND NEWLY DEVELOPED REGRESSION FORMULAS (opens in a new tab)

  4. EVALUATING THE ACCURACY OF STATURE ESTIMATION FROM TIBIAL RADIOGRAPHS USING KNOWN AND NEWLY DEVELOPED REGRESSION FORMULAS

    … stature estimation from tibial radiographs using digital measurements as an alternative to traditional osteometric tools. Stature estimation is crucial in forensic anthropology for identifying individuals, especially cases involving skeletal remains. Traditional methods rely on physical …

    montana-tech Repository record for EVALUATING THE ACCURACY OF STATURE ESTIMATION FROM TIBIAL RADIOGRAPHS USING KNOWN AND NEWLY DEVELOPED REGRESSION FORMULAS (opens in a new tab)

  5. The Accuracy and Sensitivity of ABO Electronic Cast Radiographic Program ORTHOSHARE 360 Compared to Manual Measurements

    … the accuracy, validity, and reliability of measurements obtained by MotionView's Ortho Share 360 program compared to traditional manual measurements of 3D printed models using a standardized ABO measuring gauge. In detail, the study aimed to evaluate the difference in total ABO Cast …

    marquette Repository record for The Accuracy and Sensitivity of ABO Electronic Cast Radiographic Program ORTHOSHARE 360 Compared to Manual Measurements (opens in a new tab)

  6. Accuracy of Ortho Insight 3D Digital Scanner in Mesial-Distal Tooth Measurements

    Introduction: Digital scanners and software may be used to measure mesial-distal (MD) tooth width for orthodontic diagnosis and treatment planning. Although there have been many studies performed on different digital scanners, accuracy of mesial-distal tooth measurements using the Ortho Insight 3D …

    loma-linda Repository record for Accuracy of Ortho Insight 3D Digital Scanner in Mesial-Distal Tooth Measurements (opens in a new tab)

  7. Sperm Chromatin Structure : Studies Utilizing Flow Cytometry and Digital Image Analysis

    … relate abnormal sperm chromatin structure with digital measurements of sperm head morphology. The testicular regions of male mice were exposed to x-ray doses ranging from Oto 400 rads. Forty days after exposure the mice were killed and flow cytometric measurement of acridine orange stained …

    sdstate Repository record for Sperm Chromatin Structure : Studies Utilizing Flow Cytometry and Digital Image Analysis (opens in a new tab)

  8. Three-dimensional visualization of the Berlin-Ichthyosaur State Park fossil beds from terrestrial LiDAR data

    … of this method in creating three-dimensional digital models of large fossil sites. The fossil beds are located at Berlin-Ichthyosaur State Park in Nye County, Nevada where they are protected by a permanent shelter, the Fossil Hut. Thirteen scan locations were used to survey both the exterior …

    unr Repository record for Three-dimensional visualization of the Berlin-Ichthyosaur State Park fossil beds from terrestrial LiDAR data (opens in a new tab)

  9. An Assessment of the use of Photogrammetry in Cranial Metric and Non-Metric Studies

    … 2% margin, in addition the standard deviation of digital measurements was less than that of physical measurements. However, a number of environmental and technical factors, most notably lighting and processing power, influenced the success of photogrammetric models. Photogrammetry offers …

    usm Repository record for An Assessment of the use of Photogrammetry in Cranial Metric and Non-Metric Studies (opens in a new tab)

  10. Assessing the utility of 3D modeling with photogrammetry in assigned sex estimation from the greater sciatic notch

    … of photogrammetry derived 3D models by comparing digital measurements to those obtained from the skeletal elements and to streamline the application of curvature analysis for the estimation of assigned sex from the GSN. This study utilizes the left and right os coxae from 15 skeletal individuals …

    bu Repository record for Assessing the utility of 3D modeling with photogrammetry in assigned sex estimation from the greater sciatic notch (opens in a new tab)

  11. Quantitative analysis of facial asymmetry based on three-dimensional photography: a valuable indicator for asymmetrical temporomandibular joint affection in juvenlie idiopathic arthritis patients?

    … asymmetry, Hausdorff distances). Clinical and digital measurements were related to the diagnosis of right and left TMJ involvement derived from magnetic resonance images (MRI). Results: Twenty-seven (34%) patients had an asymmetrical osseous deformity of the TMJ. By clinical evaluation, chin …

    zurich Restricted access

  12. Assessment of Dental Asymmetry Utilizing Orthodontic Study Casts Comparing Tooth Positions to the Midpalatal Raphe and Tooth Size Among Antimeres

    … Photoshop® ruler and Chicago® brand electronic digital calipers accurate to the nearest tenth of a millimeter were used for digital measurements. Measurements were made to determine the amount and direction of asymmetry along the dental midlines relative to the median palatine raphe. Transverse …

    iupui Repository record for Assessment of Dental Asymmetry Utilizing Orthodontic Study Casts Comparing Tooth Positions to the Midpalatal Raphe and Tooth Size Among Antimeres (opens in a new tab)

  13. Quantification of the variable radiocarpal ligaments pattern

    … different ways: manual with callipers, from a digital photograph using ImageJ and with a 3D digitizer to create and measure a virtual 3D model of each structure. Two parameters were analysed in three different levels: the radial, middle and ulnar length as well as the proximal, middle and …

    glasgow Download PDF for Quantification of the variable radiocarpal ligaments pattern (opens in a new tab)

  14. Sources of Uncertainty in Remote Stratigraphic Observations

    … Drone images and videos can be processed via digital photogrammetry to produce a 3D digital outcrop model (DOM). DOMs provide opportunities to “return” to an outcrop after fieldwork is complete, collect data from outcrops that are inaccessible, or may even provide opportunities to radically …

    temple Repository record for Sources of Uncertainty in Remote Stratigraphic Observations (opens in a new tab)

  15. A comparative ex-vivo study of clinical, digital and histological methods for measuring keratinized tissue width

    … approaches including conventional clinical, digital and histological measurements. Twenty samples of individual tooth specimens with attached gingiva, mucosa and attached alveolar bone were obtained from pig jaws. Vertical grooves were created on each dental crown to serve as a reference …

    temple Repository record for A comparative ex-vivo study of clinical, digital and histological methods for measuring keratinized tissue width (opens in a new tab)

  16. Tightening the large diameter anchor bolts of sign, signal, and luminaire structures

    … it became clear there was a need for cheap, digital measurements of bolt pretension. In Chapter 6, an organic sensor developed and tested for a National Cooperative Highway Research Program (NCHRP) funded project is described.</p> <p>The project found that most states experience issues with …

    iastate Repository record for Tightening the large diameter anchor bolts of sign, signal, and luminaire structures (opens in a new tab)

  17. A randomized controlled trial to compare the histomorphometric and clinical outcomes of soft tissue augmentation at the time of lateral ridge augmentation procedures

    … at the time of the surgical procedures and digitally in software after the completion of both surgical procedures. Width of keratinized tissue was assessed clinically, while soft tissue (horizontal) thickness 4 mm from the alveolar crest and soft tissue (vertical) thickness at the incision …

    uab Repository record for A randomized controlled trial to compare the histomorphometric and clinical outcomes of soft tissue augmentation at the time of lateral ridge augmentation procedures (opens in a new tab)

  18. Cyber-physical systems to monitor the efficiency and sustainability of human-centric manufacturing systems

    … Things technologies are leveraged to achieve a digital representation of workers. The acquired measurements are fed into computational algorithms to appreciate data-driven managerial insights based on the returned Key Performance and Risk indicators. The contributions of this thesis can be …

    trento Repository record for Cyber-physical systems to monitor the efficiency and sustainability of human-centric manufacturing systems (opens in a new tab)

  19. High-throughput in Situ 3-D phenotyping of cotton height, leaf area index, and boll distribution

    Hands-on measurements are often used in agronomic studies of cotton (Gossypium hirsutum L.) to determine crop growth, architecture, and maturity; which, in turn, may indicate the effects of genetics, environment, and production practices on crop productivity. Many of these growth characteristics …

    ttu Repository record for High-throughput in Situ 3-D phenotyping of cotton height, leaf area index, and boll distribution (opens in a new tab)

  20. Spatial And Temporal Variability Of Sandy Beach Sediment Grain Size And Sorting

    … around the southwest UK and high-resolution digital measurements with longer 1 m sand cores from the intertidal zone, plus grab samples from the subtidal zone, at Perranporth, indicated the presence of three quasi-permanent spatial trends. On all sandy beaches, surface sediments became …

    plymouth Repository record for Spatial And Temporal Variability Of Sandy Beach Sediment Grain Size And Sorting (opens in a new tab)

Page 1 of 2