Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 52 for “"Digital volume correlation"”.

  1. High performance digital volume correlation

    … improvements to a three-dimensional (3D) digital volume correlation (DVC) algorithm, which measures displacement and strain fields throughout the interior of a material. Our goal is to perform DVC with resolution comparable to that achieved in 2D digital image correlation, in time that is …

    uiuc Repository record for High performance digital volume correlation (opens in a new tab)

  2. Investigation of Composite Materials Using Digital Volume Correlation

    … field internal displacement and strain field. Digital Volume Correlation (DVC) is a measurement technique which generates a 3D displacement and strain field for the sample under loading. Fused filament fabrication (FFF) and hybrid braided composites has limited research to understand the …

    york Repository record for Investigation of Composite Materials Using Digital Volume Correlation (opens in a new tab)

  3. Investigation of Advanced Material Through Digital Volume Correlation Measurement Techniques

    … are often complex and difficult to predict. Digital volume correlation (DVC) offers a novel method for the deformation analysis of composite structures. Through the utilization of micro-computed tomography datasets can be obtained and utilized to visualize three-dimensional dataset for DVC. …

    york Repository record for Investigation of Advanced Material Through Digital Volume Correlation Measurement Techniques (opens in a new tab)

  4. Image-Based Fracture Mechanics with Digital Image Correlation and Digital Volume Correlation

    … with the microstructure and stress fields. Digital Image Correlation (DIC) and Digital Volume Correlation (DVC) have been widely accepted and routinely used to measure full-field displacements in many areas of solid mechanics, including fracture mechanics. However, current practise for the …

    whiterose Download PDF for Image-Based Fracture Mechanics with Digital Image Correlation and Digital Volume Correlation (opens in a new tab)

  5. Error estimation in whole bone microstrain measurement when using digital volume correlation

    … changes within the bone micro-architecture. Digital volume correlation (DVC) is a mathematical technique used to determine strain within the bone volume, by tracing the dislocation of a pattern between the 3-dimensional images. Uncertainty in the microstrain calculated arises due to …

    uiuc Repository record for Error estimation in whole bone microstrain measurement when using digital volume correlation (opens in a new tab)

  6. A protocol for physiological mechanical testing of cortical bone using digital volume correlation

    Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2022-04-06 without embargo terms

    uiuc Repository record for A protocol for physiological mechanical testing of cortical bone using digital volume correlation (opens in a new tab)

  7. Particulate composite material internal deformation measurements using x-ray microtomography and digital volume correlation

    … of particulate sizes and often high particulate volume fractions (65%-95%). Examples of these are, explosives and rocket propellants for defense and aerospace applications, asphalt concrete materials civil engineering applications and ceramic/ceramic thermal barrier coatings for turbine engines. …

    uiuc Repository record for Particulate composite material internal deformation measurements using x-ray microtomography and digital volume correlation (opens in a new tab)

  8. Digital volume correlation as a method for estimating load-induced deformations in the human spine

    Digital volume correlation (DVC) is a computational tool used to measure a 3D displacement field between a pair of 3D images (from, for example, magnetic resonance imaging (MRI), computed tomography (CT), ultrasound, etc.). Studies in biomechanics have used DVC to quantify deformations in cells, …

    bu Repository record for Digital volume correlation as a method for estimating load-induced deformations in the human spine (opens in a new tab)

  9. Investigation of damage initiation in carbon fibre reinforced polymer composites using synchrotron radiation computed tomography and digital volume correlation

    … initiation. Complementary techniques such as Digital Volume Correlation (DVC) and image segmentation have been used to analyse the strains associated with crack initiation in cross ply laminates loaded and imaged in 3D in situ. (The use of these techniques, to investigate damage initiation in …

    soton Download PDF for Investigation of damage initiation in carbon fibre reinforced polymer composites using synchrotron radiation computed tomography and digital volume correlation (opens in a new tab)

  10. Translation of an OCT-Based Digital Volume Correlation Framework from Human to Rat Eyes for Detecting IOP-Induced Optic Nerve Head Deformation

    … Optical coherence tomography combined with digital volume correlation (OCT-DVC) has been used in human eyes to quantify ONH deformation and strain in vivo, but its translation to the rat eye has not been established. The objective of this thesis was to evaluate whether a human OCT-DVC …

    jhu Repository record for Translation of an OCT-Based Digital Volume Correlation Framework from Human to Rat Eyes for Detecting IOP-Induced Optic Nerve Head Deformation (opens in a new tab)

  11. Validation of Subject Specific Computed Tomography-based Finite Element Models of the Human Proximal Tibia using Full-field Experimental Displacement Measurements from Digital Volume Correlation

    … predict internal bone mechanics (displacement). Digital volume correlation (DVC) can measure internal bone displacements and has been used to validate FE models of bone; though, its use has been limited to small specimens. The objectives of this study were to 1) establish a methodology for …

    sask Repository record for Validation of Subject Specific Computed Tomography-based Finite Element Models of the Human Proximal Tibia using Full-field Experimental Displacement Measurements from Digital Volume Correlation (opens in a new tab)

  12. Investigation of the high-temperature mechanical behaviour of oxide-oxide ceramic-matrix composites

    … with in situ X-ray computed microtomography and digital volume correlation were explored. Subsequently, residual stresses were quantified using photoluminescence piezospectroscopy.<br/>Materials with different sintering temperatures based on Nextel<sup>TM</sup> 720 fibres displayed average …

    bristol Repository record for Investigation of the high-temperature mechanical behaviour of oxide-oxide ceramic-matrix composites (opens in a new tab) Download PDF for Investigation of the high-temperature mechanical behaviour of oxide-oxide ceramic-matrix composites (opens in a new tab)

  13. The use of synchrotron x-ray micro computed tomography to study the failure mechanisms of thermal barrier coatings

    … X-ray microtomography (SX μCT) coupled with digital volume correlation (DVC). The forcebalance method relates the creep in bondcoats of precision-machined cylindrical micro-specimens to the stress acted on the bondcoat by the TGO. These precisionmachined specimens were volumetrically imaged …

    birmingham Download PDF for The use of synchrotron x-ray micro computed tomography to study the failure mechanisms of thermal barrier coatings (opens in a new tab)

  14. Impact Loading and Rapid Volumetric Assessment of Braided Composite Structures

    … materials and their internal structures through volumetric X-ray imaging. This thesis explores an automated method of rapidly characterizing the internal structures of braided composites subjected to impact testing. The developed methodology is based on algorithms that use image processing …

    york Repository record for Impact Loading and Rapid Volumetric Assessment of Braided Composite Structures (opens in a new tab)

  15. Understanding subsurface integrity in machining of cellular solids

    … processed by machining-based processing at full volume using x-ray micro-computed tomography. The structural parameters of the strut-pore network were characterized as a function of controllable parameters of cutting speed, feed rate and depth of cut. The resulting surfaces were shown to be …

    gatech Repository record for Understanding subsurface integrity in machining of cellular solids (opens in a new tab)

  16. Achieving efficiency and accuracy through kinematic integrity: a novel approach to metamaterial modelling

    … data. Displacement data is obtained via global Digital Image Correlation (DIC) and Digital Volume Correlation (DVC). Measuring the displacement fields via Finite Element based DIC/DVC yields the true local deformation of the structure. The technique is demonstrated through the creation of a …

    freiburg-diss Repository record for Achieving efficiency and accuracy through kinematic integrity: a novel approach to metamaterial modelling (opens in a new tab)

  17. Application of deep learning in geotechnical engineering with a focus on constitutive models

    … the advent of new experimental setups such as digital image correlation, X-ray computed tomography, digital volume correlation, and computational methods, the potential to obtain large stress-strain databases that account for complex loading and boundary conditions, has significantly increased. …

    mcmaster Repository record for Application of deep learning in geotechnical engineering with a focus on constitutive models (opens in a new tab)

  18. IN VIVO BIOMECHANICAL STRAIN RESPONSE OF THE LAMINA CRIBROSA TO INTRAOCULAR PRESSURE CHANGE AS A RESULT OF GLAUCOMA MEDICATION CHANGE

    … Radial optical coherence tomography (OCT) image volumes were acquired and intraocular pressure (IOP) was measured for 23 eyes from 15 patients before starting glaucoma medication and after a duration of 7.3 ± 1.4 days. Pre- and post-treatment image volumes were compared using digital volume …

    jhu Repository record for IN VIVO BIOMECHANICAL STRAIN RESPONSE OF THE LAMINA CRIBROSA TO INTRAOCULAR PRESSURE CHANGE AS A RESULT OF GLAUCOMA MEDICATION CHANGE (opens in a new tab)

Page 1 of 3