Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 42 for “"Digital volume correlation (DVC)"”

  1. Impact Loading and Rapid Volumetric Assessment of Braided Composite Structures

    … materials and their internal structures through volumetric X-ray imaging. This thesis explores an automated method of rapidly characterizing the internal structures of braided composites subjected to impact testing. The developed methodology is based on algorithms that use image processing …

    york Repository record for Impact Loading and Rapid Volumetric Assessment of Braided Composite Structures (opens in a new tab)

  2. Investigation of Composite Materials Using Digital Volume Correlation

    … field internal displacement and strain field. Digital Volume Correlation (DVC) is a measurement technique which generates a 3D displacement and strain field for the sample under loading. Fused filament fabrication (FFF) and hybrid braided composites has limited research to understand the …

    york Repository record for Investigation of Composite Materials Using Digital Volume Correlation (opens in a new tab)

  3. Investigation of Advanced Material Through Digital Volume Correlation Measurement Techniques

    … are often complex and difficult to predict. Digital volume correlation (DVC) offers a novel method for the deformation analysis of composite structures. Through the utilization of micro-computed tomography datasets can be obtained and utilized to visualize three-dimensional dataset for DVC. …

    york Repository record for Investigation of Advanced Material Through Digital Volume Correlation Measurement Techniques (opens in a new tab)

  4. Achieving efficiency and accuracy through kinematic integrity: a novel approach to metamaterial modelling

    … data. Displacement data is obtained via global Digital Image Correlation (DIC) and Digital Volume Correlation (DVC). Measuring the displacement fields via Finite Element based DIC/DVC yields the true local deformation of the structure. The technique is demonstrated through the creation of a …

    freiburg-diss Repository record for Achieving efficiency and accuracy through kinematic integrity: a novel approach to metamaterial modelling (opens in a new tab)

  5. Mechanical characterization of the evolution and degeneration of skeletal muscle : an optical coherence tomography and computational simulation approaches

    … under mechanical stress was measured using Digital Volume Correlation (DVC). The results verify that DMD and control muscles differ significantly in their mechanical properties and structure. Overall, this research contributes to the field of muscle tissue engineering and regenerative …

    un-colombia Repository record for Mechanical characterization of the evolution and degeneration of skeletal muscle : an optical coherence tomography and computational simulation approaches (opens in a new tab)

  6. The use of synchrotron x-ray micro computed tomography to study the failure mechanisms of thermal barrier coatings

    … X-ray microtomography (SX μCT) coupled with digital volume correlation (DVC). The forcebalance method relates the creep in bondcoats of precision-machined cylindrical micro-specimens to the stress acted on the bondcoat by the TGO. These precisionmachined specimens were volumetrically imaged …

    birmingham Repository record for The use of synchrotron x-ray micro computed tomography to study the failure mechanisms of thermal barrier coatings (opens in a new tab)

  7. High performance digital volume correlation

    … improvements to a three-dimensional (3D) digital volume correlation (DVC) algorithm, which measures displacement and strain fields throughout the interior of a material. Our goal is to perform DVC with resolution comparable to that achieved in 2D digital image correlation, in time that is …

    uiuc Repository record for High performance digital volume correlation (opens in a new tab)

  8. Investigation of damage initiation in carbon fibre reinforced polymer composites using synchrotron radiation computed tomography and digital volume correlation

    … initiation. Complementary techniques such as Digital Volume Correlation (DVC) and image segmentation have been used to analyse the strains associated with crack initiation in cross ply laminates loaded and imaged in 3D in situ. (The use of these techniques, to investigate damage initiation in …

    soton Repository record for Investigation of damage initiation in carbon fibre reinforced polymer composites using synchrotron radiation computed tomography and digital volume correlation (opens in a new tab)

  9. Verification and Validation of MicroCT-based Finite Element Models of Bone Tissue Biomechanics

    … remains challenging. Recent technique of digital volume correlation (DVC) combined with microCT images can measure internal displacements and deformation of bone specimen and therefore is able to provide experimental data for validation. However, the strain error of this experimental …

    whiterose Repository record for Verification and Validation of MicroCT-based Finite Element Models of Bone Tissue Biomechanics (opens in a new tab)

  10. IN VIVO BIOMECHANICAL STRAIN RESPONSE OF THE LAMINA CRIBROSA TO INTRAOCULAR PRESSURE CHANGE AS A RESULT OF GLAUCOMA MEDICATION CHANGE

    … Radial optical coherence tomography (OCT) image volumes were acquired and intraocular pressure (IOP) was measured for 23 eyes from 15 patients before starting glaucoma medication and after a duration of 7.3 ± 1.4 days. Pre- and post-treatment image volumes were compared using digital volume …

    jhu Repository record for IN VIVO BIOMECHANICAL STRAIN RESPONSE OF THE LAMINA CRIBROSA TO INTRAOCULAR PRESSURE CHANGE AS A RESULT OF GLAUCOMA MEDICATION CHANGE (opens in a new tab)

  11. SHORT-TERM LAMINA CRIBROSA BIOMECHANICAL RESPONSES TO MEDICATION INDUCED INTRAOCULAR PRESSURE CHANGES IN GLAUCOMA PATIENTS: VEGAN STUDY

    … investigate the accessibility of utilizing the DVC technique for capturing the characteristics of the short-term, in vivo biomechanical responses of the lamina cribrosa (LC) in patients’ hypotensive glaucoma eye drops. The primary goal of this research is to identify mechanical biomarkers for …

    jhu Repository record for SHORT-TERM LAMINA CRIBROSA BIOMECHANICAL RESPONSES TO MEDICATION INDUCED INTRAOCULAR PRESSURE CHANGES IN GLAUCOMA PATIENTS: VEGAN STUDY (opens in a new tab)

  12. Revealing Hierarchical Intervertebral Disc Biomechanics Through Multimodal X-ray Imaging

    … to mechanical strain across spatial scales. Digital volume correlation (DVC) combined with microarchitectural analysis reveals that high tensile and shear strains play a role in the cartilage to bone transition. Correlative imaging and diffraction show that bone contains narrower mineral …

    ucl Repository record for Revealing Hierarchical Intervertebral Disc Biomechanics Through Multimodal X-ray Imaging (opens in a new tab)

  13. Non-invasive prediction of bone mechanical properties of the mouse tibia in longitudinal preclinical studies

    … for the validation has been obtained using the Digital Volume Correlation (DVC) approach, the only method which can provide volumetric measurements of local displacements under loading. Good to excellent correlations between the measured and predicted displacements were found. Errors in …

    whiterose Repository record for Non-invasive prediction of bone mechanical properties of the mouse tibia in longitudinal preclinical studies (opens in a new tab)

  14. Three dimensional characterization and multi-scale modelling of deformation in biomaterials

    … deformed biomaterials have been extracted by digital volume correlation (DVC), which provides either boundary conditions for modelling or experimental comparison for simulated results. Different modelling approaches have been employed in order to provide a comprehensive understanding of …

    oxford Repository record for Three dimensional characterization and multi-scale modelling of deformation in biomaterials (opens in a new tab)

  15. Deformation and Fracture Analysis of Bio-inspired Ceramic Composite Materials

    … with in situ X-ray computed tomography (XCT) and digital volume correlation (DVC) to visualise and quantify internal strain fields and crack evolution in three dimensions. These in situ 3D characterisation methods revealed the interplay between architecture, reinforcement, and interfaces in …

    bristol Repository record for Deformation and Fracture Analysis of Bio-inspired Ceramic Composite Materials (opens in a new tab) Embargoed until 2027-03-17

  16. Characterizing the Remodeling of the Lamina Cribrosa of Glaucoma Eyes

    … using various optical imaging methods and digital volume correlation (DVC) both ex vivo and in vivo for short term IOP change. However, the LC deformations from long term remodeling have not been studied. The strain and remodeling may be biomarkers for the susceptibility of patients to …

    jhu Repository record for Characterizing the Remodeling of the Lamina Cribrosa of Glaucoma Eyes (opens in a new tab)

  17. Validation of Subject Specific Computed Tomography-based Finite Element Models of the Human Proximal Tibia using Full-field Experimental Displacement Measurements from Digital Volume Correlation

    … predict internal bone mechanics (displacement). Digital volume correlation (DVC) can measure internal bone displacements and has been used to validate FE models of bone; though, its use has been limited to small specimens. The objectives of this study were to 1) establish a methodology for …

    sask Repository record for Validation of Subject Specific Computed Tomography-based Finite Element Models of the Human Proximal Tibia using Full-field Experimental Displacement Measurements from Digital Volume Correlation (opens in a new tab)

  18. 3-D visualization and prediction of spine fractures under axial loading

    … (FE) models for predicting vertebral failure. Digital volume correlation (DVC) was used to measure the deformations sustained throughout the vertebra during compression tests. These results were compared against deformation patterns predicted using FE models created from QCT images of the …

    bu Repository record for 3-D visualization and prediction of spine fractures under axial loading (opens in a new tab)

  19. Error estimation in whole bone microstrain measurement when using digital volume correlation

    … changes within the bone micro-architecture. Digital volume correlation (DVC) is a mathematical technique used to determine strain within the bone volume, by tracing the dislocation of a pattern between the 3-dimensional images. Uncertainty in the microstrain calculated arises due to …

    uiuc Repository record for Error estimation in whole bone microstrain measurement when using digital volume correlation (opens in a new tab)

  20. 3-D visualization and prediction of spine fractures under axial loading

    … (FE) models for predicting vertebral failure. Digital volume correlation (DVC) was used to measure the deformations sustained throughout the vertebra during compression tests. These results were compared against deformation patterns predicted using FE models created from QCT images of the …

    bu Repository record for 3-D visualization and prediction of spine fractures under axial loading (opens in a new tab)

Page 1 of 3