Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 29 for “"Dipole magnet"”.

  1. LHC main dipole magnet circuits: sustaining near-nominal beam energies

    … an interconnect discontinuity in one of the main dipole circuit's 13 kA superconducting busbars, a catastrophic quench event occurred during initial magnet training, causing significant physical system damage. Furthermore, investigation into the cause found that such discontinuities were not only …

    glasgow Download PDF for LHC main dipole magnet circuits: sustaining near-nominal beam energies (opens in a new tab)

  2. DESIGN AND STUDY OF THE IRIS 10 T ENERGY SAVING DIPOLE MAGNET FOR ACCELERATORS: ESMA

    … in 1987, tape manufacturing suitable for magnet windings has only recently been optimized. REBCO tapes belong to the class of High Temperature Superconductors (HTS), a class of materials which remain superconducting at temperatures higher than liquid nitrogen, in contrast to classical Low …

    milano Repository record for DESIGN AND STUDY OF THE IRIS 10 T ENERGY SAVING DIPOLE MAGNET FOR ACCELERATORS: ESMA (opens in a new tab)

  3. Diagnostics of the Fermilab Tevatron using an AC dipole

    … Tevatron’s beam optical lattice. An oscillating dipole magnet, referred to as an AC dipole, is one of such a tool to non-destructively assess the optical properties of the synchrotron. We discusses development of an AC dipole system for the Tevatron, a fast-oscillating (f∼20 kHz) dipole magnet …

    texas Repository record for Diagnostics of the Fermilab Tevatron using an AC dipole (opens in a new tab)

  4. GRAND UNIFIED MAGNET (PARTICLE ACCELERATOR)

    … describes a high field two mode superferric dipole magnet for particle accelerators. At low field it behaves as a ferric magnet while at high field as a ${\rm cos}\theta$ magnet. It retains the advantages of a low field ferric magnet: substantial superconductor saving, easy fabrication and …

    rice Repository record for GRAND UNIFIED MAGNET (PARTICLE ACCELERATOR) (opens in a new tab)

  5. Understanding the plasma and improving extraction of the ISIS Penning H- ions source

    … new regime whereby the analysing sector dipole magnet housed inside a refrigerated 'cold box', presently used on ISIS, is replaced by an on-axis extraction system. The new extraction system incorporates a novel einzel lens with an elliptical aperture. This is the first demonstration of an …

    oxford Repository record for Understanding the plasma and improving extraction of the ISIS Penning H- ions source (opens in a new tab)

  6. CHARACTERIZATION OF THE GEM CHAMBERS FOR THE SBS/BB FRONT TRACKER AT JLAB HALL A

    … the new spectrometer will consist of a dipole magnet, three charged particle trackers, two identical proton polarimeters and a segmented hadron calorimeter. The main requirements for the SBS tracking system come from the upcoming experiments devoted to the measurement of the nucleon …

    catania Repository record for CHARACTERIZATION OF THE GEM CHAMBERS FOR THE SBS/BB FRONT TRACKER AT JLAB HALL A (opens in a new tab)

  7. Measurement of the polarization of the muon beam for the SMC experiment

    … hodoscope which identifies the $\mu\sp{+}$ and a dipole analyzing magnet. The spectrometer includes the dipole magnet and several multi-wire proportional chambers which measure the momentum of the $e\sp{+}.$ Identification of decay positrons is based on the energy deposited in a lead glass …

    rice Repository record for Measurement of the polarization of the muon beam for the SMC experiment (opens in a new tab)

  8. LWFA diagnostics development for ATLAS-300 and nonlinear plasma wavelength scalings

    … of scintillating screens and permanent dipole magnets were carried out. On the plasma diagnostics side, a few-cycle probe beam for producing fs-snapshots of the plasma wave was developed. Specifically, the light-emitting efficiency of nine commonly used scintillating screen types were …

    lmu-germany Repository record for LWFA diagnostics development for ATLAS-300 and nonlinear plasma wavelength scalings (opens in a new tab)

  9. Simulation Study of Magnetic Field Effects in the Pair Spectrometer Luminosity Detector for ePIC Experiment at the Electron Ion Collider

    We aim to address the challenge of optimizing the magnetic field configuration that guides pair-produced e+e− from the conversion foil to the pair spectrometer trackers and calorimeters. This involves systematically exploring a range of tunable parameters that influence the acceptance rate, the …

    houston Repository record for Simulation Study of Magnetic Field Effects in the Pair Spectrometer Luminosity Detector for ePIC Experiment at the Electron Ion Collider (opens in a new tab)

  10. Search for solar axions with the CCD detector at CAST (CERN Axion Solar Telescope)

    … with virtual photons of the strong electromagnetic field. In this experiment, the solar axions can be converted to photons in the field of a 9 Tesla superconducting magnet. At both ends of the 10 m long dipole magnet, three different X-ray detectors were installed, which are sensitive in …

    freiburg-diss Repository record for Search for solar axions with the CCD detector at CAST (CERN Axion Solar Telescope) (opens in a new tab)

  11. Third-order charged particle beam optics

    The motion of a charged particle through a magnetic field configuration can be described in terms of deviation from a certain ideal trajectory. One uses power series expansion of the phase-space coordinates to obtain the transfer matrices for a particular optical system. In this thesis we present a …

    uiuc Repository record for Third-order charged particle beam optics (opens in a new tab)

  12. Spectroscopy of neutron unbound states in neutron rich carbon

    … fragments were bent from the beam axis by a dipole magnet and their properties measured by a suite of charged particle detectors sufficient to identify individual reaction products and reconstruct momentum vectors at the reaction target. Neutrons were detected at forward angles by the Modular …

    msu Repository record for Spectroscopy of neutron unbound states in neutron rich carbon (opens in a new tab)

  13. The measurement of the production cross section ratio of identified hadrons and the calibration of the magnetic distortion in RICH1 at LHCb

    … necessary. A system for the calibration of the magnetic distortion induced by the LHCb dipole magnet onto the photon detectors is described. The system currently provides calibration parameters used in the LHCb event reconstruction software and introduces a critical improvement to the overall …

    oxford Repository record for The measurement of the production cross section ratio of identified hadrons and the calibration of the magnetic distortion in RICH1 at LHCb (opens in a new tab)

  14. Magnetic distortion calibration for the LHCb Ring Imaging Cherenkov (RICH) Detector, and the search for CP violation in D*+ -> D0(K-K+)pi+ decays

    … necessary. A system for the calibration of the magnetic distortion induced by the LHCb dipole magnet on the photon detector is described. The system currently provides the calibration parameters used in the LHCb event reconstruction software and allows for a significant improvement in the …

    oxford Repository record for Magnetic distortion calibration for the LHCb Ring Imaging Cherenkov (RICH) Detector, and the search for CP violation in D*+ -> D0(K-K+)pi+ decays (opens in a new tab)

  15. Beam-Induced Radiation Heating on the Superconducting Undulator at the Advanced Photon Source

    … Undulator (SCU). The superconducting magnet is thermally isolated from the beam vacuum chamber, which absorbs the beam-induced heating. Previous beam induced heat load studies at other laboratories had not included a robust calculation of radiation heating from the upstream dipole …

    purdue-thes Repository record for Beam-Induced Radiation Heating on the Superconducting Undulator at the Advanced Photon Source (opens in a new tab)

  16. An investigation of the magnetic field of full flux penetration of superconducting materials for radio-frequency cavities

    … gradient, Eacc. To increase Eacc, the magnetic field, B, on the accelerating cavity wall, Bsurf, must be increased. There are multiple methods to increase Bsurf such as new, novel materials. One method to increase Eacc is to use multilayer structures, which consist of superconducting …

    lancaster Download PDF for An investigation of the magnetic field of full flux penetration of superconducting materials for radio-frequency cavities (opens in a new tab)

  17. A magnetic pair spectrometer to detect photon splitting

    … energy resolution and efficiency of a magnetic gamma ray pair spectrometer (PS), investigated using the photon tagger at the Saskatchewan Accelerator Laboratory (SAL). This instrument employs the well known process of pair production, with subsequent momentum analysis of the …

    sask Repository record for A magnetic pair spectrometer to detect photon splitting (opens in a new tab)

  18. High-brightness electron beams from a DC, high-voltage, GaAs photoemission gun

    … used a scanning slit, wire scanners, and a dipole magnet to measure the transverse emittance and momentum spread for beam conditions ranging from the emittance-dominated to the space-charge-dominated regimes. As the microbunch charge was varied from 0.5 to I25 pC, the transverse emittance …

    uiuc Repository record for High-brightness electron beams from a DC, high-voltage, GaAs photoemission gun (opens in a new tab)

  19. Simulation of the Ferrofluid Interface

    … faithful model. The simulator accommodates any magnetic field and initial configuration of the fluid. Due to the high level of interface detail required by the Rosensweig instability we developed improved curvature estimation and surface tracking methods. We use a normal-aligned height function …

    waterloo Repository record for Simulation of the Ferrofluid Interface (opens in a new tab)

  20. Measurement of the total flux averaged neutrino induced neutral current elastic scattering cross section with the T2K Pi-Zero detector

    … on a carbon target and focused with three magnetic horns to produce a high intensity and nearly pure muon neutrino beam with a peak energy of 600 MeV at a 2.5º axis angle. The muon neutrino beam travels 295 km across Japan to the Super Kamiokande (SK) water Cherenkov detector in the Kamioka …

    colostate Repository record for Measurement of the total flux averaged neutrino induced neutral current elastic scattering cross section with the T2K Pi-Zero detector (opens in a new tab)

Page 1 of 2