Developments and applications of solid phase microextraction (SPME) coupled to direct analysis in real time (DART) and approaches towards small volume analysis
… microextraction (SPME) has been rapidly developing since its invention in 1990. Due to a flexible design and the ability to implement various extractive coatings, SPME has found use in numerous applications. One such application is the coupling of SPME to Direct Analysis in Real Time (DART), an …
-
Exploring Applicability of Direct Analysis in Real Time with Mass Spectrometry (DART-MS) to Identify Homemade Explosive Residues Post-Blast
Application of Direct-Analysis-in-Real-Time (DART) ionization with mass spectrometry (DART-MS) to identify explosives from post-blast residues is presented. Explosives studied represent current threats encountered in criminal investigations: homemade organic peroxides, binary explosives and …
-
Ambient Ionization Mass Spectrometry Analysis Pertaining To Biofuel Process Development
… (MS) has undergone a revolution with the introduction of a new group of desorption/ionization (DI) techniques known collectively as Ambient Ionization mass spectrometry. Ambient ionization mass spectrometry allows for direct analysis of analytes and typically requires little or no sample …
-
Measurement of denatonium benzoate in antifreeze with quantitative DART-MS method development and abbreviated method validation
… benzoate (DB), the most bitter compound in the world, is a white powder that is often added to toxic products such as antifreeze. A small amount of this chemical is enough to make products unbearable to ingest. When the toxic component of antifreeze, ethylene glycol, is present in …
-
Differential Mobility Spectrometry-Mass spectrometry (DMS-MS) for Forensic and Nuclear-Forensic applications
In forensics and nuclear-forensics, the current lab-based analytical technique employed can be laborious, time consuming, and less suitable for in-situ and real time screening. However, it is important to develop fast and fieldable instrumental technique, without a tradeoff for its high throughput, …
-
Novel Extractions of Trace-Level Compounds using PDMS Sorbent Polymers for High-Throughput Analyses and Mass Spectral Imaging
… and food products. This is especially true for wine and grapes where large numbers of samples require analyses to assess smoke taint exposure, characterize breeding programs, etc. Solid phase microextraction (SPME) is widely used in conjunction with gas chromatography-mass spectrometry (GC-MS) …
-
Development and Characterization of Plasma-based Sources for Ambient Desorption/Ionization Mass Spectrometry
… for mass spectrometry has recently appeared in the literature to yield a field that is collectively referred to as Ambient Desorption/Ionization-Mass Spectrometry (ADI-MS). These sources include, among others, Desorption ElectroSpray Ionization (DESI), Direct Analysis in Real Time (DART), the …
-
Applications and fundamental characterization of open air and acoustic-driven ionization methods
One of the most fundamental challenges in analytical mass spectrometry (MS) is the efficient conversion of neutral molecules into intact gas-phase ions. In this thesis, I investigate the capabilities of various new and established ionization techniques including (a) the Array of Micromachined …
-
MASS SPECTROMETRY FOR THE HIGH-THROUGHPUT QUANTIFICATION AND MECHANISTIC INVESTIGATION OF ODOR-ACTIVE VOLATILES IN GRAPES AND WINE
… rapid quantification of odor-active volatiles in food matrices. Quantitative analyses of trace-level volatile compounds are routinely performed as an objective measure of flavor in foodstuffs and raw materials. Standard analytical methods based on gas chromatography-mass spectrometry (GC-MS) …
-
Rapid and Direct Analysis of Samples of Environmental Concerns
… numerous techniques are available for contaminant detection in a variety of matrices, they are either laborious, costly or specifically adapted to a certain class of analysts. Thus, it is imperative to develop novel approaches for simple, fast, inexpensive and reliable methods to …
-
Development of transmission mode desorption electrospray ionization (TM-DESI)
… emerged with the nearly simultaneous introduction of two ambient ionization techniques: desorption electrospray ionization (DESI) and direct analysis in real time (DART). The ability to integrate near instantaneous sample analysis with the specificity of mass spectrometry opened up a …
-
Investigations into Ambient Ionization Mechanisms: Electrospray Ionization and Direct Analysis in Real Time Mass Spectrometry
… designs afford little-to-no fragmentation, allowing characterization of intact molecules. However, this does not assure that detected ions are representative of the analytes’ natural state. Ionization mechanisms are generally complex and rarely fully understood. Fundamental research into these …
-
Development of high-sensitivity atmospheric pressure (ap) matrix-assisted laser desorption/ionization (maldi) and open air ionization techniques for the analysis of biomolecules by mass spectrometry
… celebrated as a soft ionization method for analyzing very diverse biological species including large proteins, peptides, carbohydrates, lipids and metabolites. The fact that MALDI is tolerant to salts and buffers and that it mostly produces singly charged ions from intact biomolecules is …
-
Laser-assisted Spectrometry and Spectroscopy for Open-air and in Situ Analyses
Many areas, such as medical diagnosis, forensic analysis, and environmental supervision require advanced analytical techniques. These techniques serve as our eyes and help us see what we cannot see. Conventional analytical methods require tedious procedures, such as liquid chromatography, which …
-
Trajectory reconstruction by analysis of trace evidence on spent bullets fired through building materials: analysis by microscopy and direct analysis in real time
Trajectory reconstruction of shooting incidents can help investigators determine critical case information regarding the number of shooters involved, their location(s), and intent. The examination of trace amounts of intermediate target materials collected on the surface of spent bullets provides …
-
Ambient ionization mass spectrometry for the forensic screening of pharmaceuticals and the determination of potential drug candidates
Ambient mass spectrometry (MS) is a new and growing sub-field in MS which has opened new research avenues, particularly for applications relating to the analysis of solid samples. Results on the implementation and application of ambient MS techniques including: desorption electrospray ionization …
-
Forensic analysis of the psychoactive alkaloids harmine and harmaline in peganum harmala seeds
The Peganum harmala plant is a flowering shrub that produces small, dark brown seeds in pods. These seeds contain the hallucinogenic alkaloids harmine and harmaline. As such, they have been historically used for shamanic rites and folk medicine. Presently, P. harmala seeds are commercially …
-
Portable, Solid-Phase Microextraction Low Temperature Plasma Ionization Source for Mass Spectrometry
… known MS ionization methods are significantly hindered by ion suppression that is caused by the competition for charge between analytes of interest and other species present in the sample matrix. To approach this key problem without using chromatography and/or sample preparation which can be …
-
Detecting fentanyl, norfentanyl, and fentanyl analog metabolites in synthetic urine using biocompatible-solid phase microextraction and direct analysis in real time-mass spectrometry
Since the late 1990s, the United States has been facing an epidemic involving an increasing number of opioid overdose deaths. This rapid increase calls for the development and optimization of rapid analytical techniques. Direct Analysis in Real Time (DART®) is an ambient ionization technique that, …
-
High throughput quantitative analysis of four commonly encountered drug metabolites in synthetic urine via biocompatible-solid phase microextraction and direct analysis in real time-mass spectrometry
Since 2011, toxicology labs across the United States have faced an ever-increasing caseload, with backlogs and analytical turn-around times that continue to grow despite efforts to increase sample throughput. Sample preparation is often the more time-consuming, labor-intensive, and error-prone …