Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 34 for “"Direct filtration"”.
-
Direct filtration of Chlorella and Scenedesmus suspensions for potable water treatment
… with tap water for use in laboratory-scale sand filtration experiments. A total of 98 filter runs were performed. Four types of coagulation were used; no coagulants, ferric chloride, aluminum sulfate and cationic polymer. For all coagulation modes, the effects of prechlorination were tested. …
-
Direct filtration using coarse media and dual media filters in series
<p>A filtration system consisting of coarse media filters in series with standard dual media filters was proposed and evaluated as an alternative for direct filtration of high turbidity waters. The coarse media filters utilized a 3.08 mm uniform sand with a media depth of 1.32 m;The study was …
-
Evaluation of alternative pretreatment methods for use in direct filtration water treatment
… of the results with respect to future use in direct filtration. The performance of the coagulant, coagulant aid, and primary coagulant polymer was evaluated by altering the flocculation and sedimentation retention times in the pretreatIDEnt process chain. Among the water quality parameters …
-
A laboratory study of factors affecting the applicability of direct filtration water treatment
… turbidity that could be treated using selected direct filtration treatment schemes and to compare the results of direct filtration and conventional water treatment. A dual media, granular filter employing coal and sand was used to treat New River water with turbidity adjusted by addition of …
-
Design of a lab scale direct-filtration system and its application in process lab
… cycle of treatment. This project fabricated a direct-filtration pilot system in EPSC and generated a laboratory manual for education purpose. Engineering applications such as clean bed head loss calculation, backwash flowrate determination, multimedia density calculation and run length …
-
Evaluating Direct Filtration as an Alternative to Conventional Carbon-Based Advanced Treatment for Indirect Potable Reuse
… flocculation, sedimentation, ozonation, biofiltration, granular activated carbon (GAC) adsorption, and ultraviolet disinfection to secondary effluent to produce water that meets drinking water standards for managed aquifer recharge. HRSD is considering implementing direct filtration as an …
-
Adequação das condições operacionais e estruturais de uma estação de tratamento de água por filtração direta
… to reformulate the treatment system. Downflow direct filtration is an effective, low-cost and easy-to-operate treatment technology, requiring, however, that the color and turbidity values of the influent water are low, among other requirements. One way to circumvent this limitation in water …
-
Comparação da filtração direta descendente com a dupla filtração no tratamento da água de uma lagoa costeira tropical
… have a low sedimentation rate, making direct filtration technologies generally more suitable. However, some tropical coastal lagoons may exhibit relatively high turbidity (and color) values during periods of intense tropical rainfall or due to anthropogenic degradation of the watershed. …
-
Removal of aquatic organic matter and humic substances by selected water treatment processes
… An assessment is made of the performance of direct filtration, conventional treatment, and lime softening in removing trihalomethane (THM) precursors from a diverse array of water sources. A comparison is made between conventional treatment and direct filtration in removing THM precursors …
-
The role of polyelectrolytes in water treatment.
… in water treatment, with an emphasis on direct filtration and, in particular, experimental pilot plant work. The definitions, chemical and physical natures of organic synthetic and natural polyelectrolytes are described. Their advantages and disadvantages for use in water treatment are …
-
Adequação das condições operacionais de uma ETA “Convencional” que trata água com cor e turbidez baixas
… In some cases WTP enables the bypass of water directly to the filter (with or without pre-flocculation), since the decantion units practically lost its function and ETA, although it is physically configured as a complete cycle, it operates as a direct filtration system. Despite the advantages …
-
Evaluation of the Effect of Coagulant Addition on Organics Removal and The Performance of Submerged Membrane Pilot Plants Treating Missouri River Water
Microfiltration (MF) and Ultrafiltration (UF) membrane installations have exponentially increased in recent years in order to treat more complex source waters and to comply with more stringent drinking water regulations. Submerged membrane technology is a relatively new technology compared to low …
-
Ensaios de tratabilidade aplicados a determinação de parâmetros para dimensionamento de processos de tratamento de água de manancial eutrofizado
… tests developed in this research simulated direct filtration (laboratory filters) and pre-oxidation with chlorine and powdered activated carbon adsorption. The research included the evaluation of the coagulants aluminum hydrochloride (HCA) and alum (SA). The development of the research …
-
Διεργασία της διήθησης πόσιμου νερού ταμιευτήρων σε βαθύ στρώμα υλικών
The objective of this work is to study Deep Bed Filtration (DBF) of surface water, intended for the production of drinking water under real conditions. Specifically the objective includes:- the study of DBF, with low quality feed water, as to its suspended solid content- the study of the …
-
Otimização do tratamento de água de manancial com baixa turbidez e cor elevada utilizando filtração direta e dupla filtração
… pilot scale, as treatment techniques for double filtration and direct filtration, with pre-oxidation and coagulation for the treatment of reservoir water with a high density of cyanobacteria, low turbulence and color seeking to obtain the most robust, that is, more stable in the process. The …
-
The Critical Role of Chemical Pre-Treatment in Ensuring Cryptosporidium Removal by Filtration of High Quality Source Water
… on surface water utilize chemically-assisted filtration (CAF) as a key barrier against the passage of protozoan pathogens, like Cryptosporidium spp. oocysts, to treated water. The goal of this work was to enable system-specific and potentially dynamic assessment of oocyst removal by CAF by …
-
Λειτουργία πιλοτικού συστήματος βιοαντιδραστήρα υπερδιηθήσεως στην επεξεργασία αστικών λυμάτων
A pilot scale hollow-fiber ultrafiltration unit (ZW-10) was initially installed in the wastewater treatment plant of Rethymno and then transferred in the wastewater treatment plant of Chania, Crete, Greece. The system was initially fed with treated unchlorinated effluent. While the system was in …
-
Caracterização de resíduos gerados em ETA de filtração direta em escala real
… the residual stream generated by a full-scale direct filtration DWTP allows the gathered results and subsequent generated data to be reference to correlated studies about the residuals generation in sceneries with such technical, technological and climatic similarities. The study presents the …
Page 1 of 2