Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 41 for “"Discharge Measurement"”

  1. Online partial discharge measurement in a high noise environment

    This thesis deals with the online measurement of partial discharge (PD) in a high-voltage direct current (HVDC) converter station. The HVDC station is a particularly challenging environment for PD measurement due to elevated interference levels caused from the switching of the thyristor-controlled …

    manitoba Repository record for Online partial discharge measurement in a high noise environment (opens in a new tab)

  2. Discharge Measurement and Energy Efficiency Evaluation of Irrigation Pumping Plants

    … pumping plants in South Dakota. Pumping plant discharge, a key parameter in the calculation of pumping plant efficiency, is often difficult to measure in the field. A project was initiated at South Dakota State University in 1976 to investigate field pumping plant efficiencies. The following …

    sdstate Repository record for Discharge Measurement and Energy Efficiency Evaluation of Irrigation Pumping Plants (opens in a new tab)

  3. Developing an acoustic discharge measurement technique for hydroelectric performance testing

    … the information obtained by performance testing, discharge is the most difficult to measure accurately. It is envisioned that acoustic transit-time velocity measurement technology can be applied at low-head plants to obtain more accurate discharge measurements over current practices. The technique …

    manitoba Repository record for Developing an acoustic discharge measurement technique for hydroelectric performance testing (opens in a new tab)

  4. Stream Discharge Measurement Using A Large-Scale Paticle Image Velocimetry Prototype

    … been developed for the establishment of stage-discharge relationships due to concerns about costs, accuracy, and safety of traditional discharge estimation methods. One emerging technology for measuring open-channel flow is Large-Scale Particle Image Velocimetry (LSPIV). LSPIV is a system …

    vt Repository record for Stream Discharge Measurement Using A Large-Scale Paticle Image Velocimetry Prototype (opens in a new tab)

  5. Design and Implementation of Partial Discharge Measurement Sensors for On-line Condition Assessment of Power Distribution System Components

    … applicable to the network. In this work partial discharge (PD) measurements have been considered for insulation condition assessment of distribution system components such as overhead covered conductors (CCs) and cables. A high frequency Rogowski coil induction sensor is designed for this …

    aalto Repository record for Design and Implementation of Partial Discharge Measurement Sensors for On-line Condition Assessment of Power Distribution System Components (opens in a new tab)

  6. Flow measurement in open channels by combined use of free surface PİV and CFD

    Stream discharge measurement in open channels is of great importance in hydraulic engineering. For many years, classical devices such as propellers, current meters and weirs have been used for this purpose. In recent times, non-intrusive methods such as PIV (Particle Image Velocimetry) and PTV …

    metu Repository record for Flow measurement in open channels by combined use of free surface PİV and CFD (opens in a new tab)

  7. Investigation of Generalized Watershed Loading Functions Predictions On Sodus East Creek Watershed

    … and sediment and nutrient loads. Actual discharge and sediment and nutrient loads were measured by conventional hydrologic and chemical techniques. During a two year period, the model explained 44 % of the total monthly variability in discharge. Total discharge was underestimated by an …

    brockport Repository record for Investigation of Generalized Watershed Loading Functions Predictions On Sodus East Creek Watershed (opens in a new tab)

  8. Experimental investigation on sharp crested rectangular weirs

    Sharp crested rectangular weirs used for discharge measurement purposes in open channel hydraulics are investigated experimentally. A series of experiments were conducted by measuring discharge and head over the weir for different weir heights for full width weir. It is seen that after a certain …

    metu Repository record for Experimental investigation on sharp crested rectangular weirs (opens in a new tab)

  9. Avaliação do uso de modelos hidrodinâmicos, suas limitações, efeitos de escala e da representação topográfica

    … Exist two hydrology monitoring stations with discharge measurement, which allowed the evaluation of the behavior of the water level in the monitoring sections in the hydrodynamic models, when the roughness coefficient of Manning was altered. As a conclusion, the results of the models were …

    brazil-uerj Repository record for Avaliação do uso de modelos hidrodinâmicos, suas limitações, efeitos de escala e da representação topográfica (opens in a new tab)

  10. Leveraging Technology to Add Value to a Phase II NPDES Permit

    In 1999, Phase II of the National Pollutant Discharge Elimination System engaged operators of small Municipal Separate Storm Sewer Systems (MS4) in the control of runoff from urban areas. The complex task of urban runoff mitigation has been investigated for several decades, resulting in a large …

    vt Repository record for Leveraging Technology to Add Value to a Phase II NPDES Permit (opens in a new tab)

  11. Discharge estimation techniques for hydraulic efficiency testing

    … turbines is used to define the head-power-discharge relationship for a turbine/generator; this relationship is used to identify the peak operating point for a turbine. Of the variables used to determine this relationship, discharge is most difficult to measure accurately in real time and is …

    manitoba Repository record for Discharge estimation techniques for hydraulic efficiency testing (opens in a new tab)

  12. Analyse des erreurs dues à l'écoulement dans la mesure de débit par la méthode acoustique : approches expérimentale et numérique

    The precise flow-rate measurement is a basic problem in the management and the exploitation of a hydraulic power-plant. The efficiency characterisation of an hydraulic machinery or of a water distribution net is linked to the accurate knowledge of the flow-rate. As well as the usual measurement …

    epfl Repository record for Analyse des erreurs dues à l'écoulement dans la mesure de débit par la méthode acoustique : approches expérimentale et numérique (opens in a new tab)

  13. SPRING DISCHARGE MONITORING IN LOW-RESOURCE SETTINGS: A CASE STUDY OF CONCEPCIÓN CHIQUIRICHAPA, GUATEMALA

    … settings presents special challenges. Spring discharge was monitored monthly in six municipal springs during the author’s Peace Corps assignment, from May 2011 to March 2012, and water level height was monitored in two spring boxes over the same time period using automated water-level loggers. …

    mtu Repository record for SPRING DISCHARGE MONITORING IN LOW-RESOURCE SETTINGS: A CASE STUDY OF CONCEPCIÓN CHIQUIRICHAPA, GUATEMALA (opens in a new tab)

  14. Comparison of Two Potential Streamgage Locations on Scott Creek at Swanton Pacific Ranch, California

    … for the installation of a streamgage to measure discharge. Each location offers unique considerations and challenges in gage construction and discharge measurement capabilities. A detailed flood frequency analysis was completed using a direct watershed comparison, direct equations developed by …

    calpoly Repository record for Comparison of Two Potential Streamgage Locations on Scott Creek at Swanton Pacific Ranch, California (opens in a new tab)

  15. Partial discharge measurements in high voltage motors.

    … technique for detecting and locating partial discharges in the stator winding of a high voltage electrical machine. This technique forms part of an on-line health monitoring strategy for the insulation of high voltage machines. Existing diagnostic techniques and partial discharge measurement …

    rgu Repository record for Partial discharge measurements in high voltage motors. (opens in a new tab)

  16. EVALUATION OF THE LIFE EXPECTANCY OF UNDERGROUND POWER CABLES

    … to AC high voltage withstand, partial discharge measurement, capacitance measurement, DC high voltage for insulation resistance measurement and impulse breakdown. The length of the test samples was found to be too short for practical breakdown testing, suffering from flashover, leakage …

    nus Repository record for EVALUATION OF THE LIFE EXPECTANCY OF UNDERGROUND POWER CABLES (opens in a new tab)

  17. Measurement and Prediction of Stage and Discharge With Ground-Based Imagery

    … and much more depend on accurate water level and discharge measurement. Greater and more complex water resource needs for parties with competing interests demand more detailed models and effective science communication than are possible with the traditional scalar measurements. The scientific …

    nebraska Repository record for Measurement and Prediction of Stage and Discharge With Ground-Based Imagery (opens in a new tab)

  18. Margaret White Springs Recharge Study, Buffalo National River, North-central Arkansas, USA

    … tens of cubic feet per second of flow to river discharge on average, yet the source of the water has not been fully studied or documented. The spring is located approximately 4 miles downstream from Robertson Hole, a losing reach of the river. At Robertson Hole the river loses a significant …

    arkansas Repository record for Margaret White Springs Recharge Study, Buffalo National River, North-central Arkansas, USA (opens in a new tab)

  19. Low Power Signal Processing Techniques for Radiometric Partial Discharge Detection in Wireless Sensor Network.

    … monitoring of insulation faults known as partial discharge. Traditional techniques for this require physical connection of sensors to plant equipment to be monitored, leading to potentially high cost and system complexity. A non-invasive and significantly less costly approach is the use of …

    huddersfield Repository record for Low Power Signal Processing Techniques for Radiometric Partial Discharge Detection in Wireless Sensor Network. (opens in a new tab)

  20. Using online partial discharge measurements to optimise asset management of medium voltage cable terminations

    … dissertation focuses on using online partial discharge measurements to optimize asset management of medium voltage cable terminations. Cable terminations as an asset portfolio within asset management is discussed with reference to international asset management standard. The importance of …

    nwu-za Repository record for Using online partial discharge measurements to optimise asset management of medium voltage cable terminations (opens in a new tab)

Page 1 of 3