Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 37 for “"Displacement Estimation"”.

  1. Strain-based displacement estimation for precision spacecraft structures

    … telescopes, determination of in-orbit structural displacement and its control is very important. While this kind of measurement is relatively easy to carry out in a laboratory setting, it can be problematic in a real world environment. A procedure for the real-time determination of displacements …

    nps Repository record for Strain-based displacement estimation for precision spacecraft structures (opens in a new tab)

  2. Accurate and Precise Displacement Estimation for Ultrasound Elastography

    Accurate and Precise Displacement Estimation for Ultrasound Elastography Morteza Mirzaei, Ph.D. Concordia University, 2021 Elastography is a technique for detecting pathological tissue alterations by extracting mechanical properties of the tissue. It can be performed using different imaging …

    concordia Download PDF for Accurate and Precise Displacement Estimation for Ultrasound Elastography (opens in a new tab)

  3. Robust Displacement Estimation for Ultrasound Elastography and Thermal Imaging

    … we focus on improving the robustness of a displacement estimation method based on dynamic programming, addressing multiple weak points. We propose a set of tools which can improve its ability to overcome displacement discontinuities and regions of poorly correlated RF data. The method is …

    jhu Repository record for Robust Displacement Estimation for Ultrasound Elastography and Thermal Imaging (opens in a new tab)

  4. Sensorless Out-of-Plane Displacement Estimation for Freehand 3D Ultrasound Applications

    … (FDS) can be used to estimate the out-of-plane displacement between ultrasound images in sensorless 3D freehand systems. This method requires the B-scans to contain mostly FDS pattern but this kind of pattern is rare in scans of real tissue. One way around this problem is to quantify the amount …

    carleton Repository record for Sensorless Out-of-Plane Displacement Estimation for Freehand 3D Ultrasound Applications (opens in a new tab)

  5. Deep Learning Methods for Impact Load Identification and Displacement Estimation in Structures

    … longevity of critical infrastructure. Estimating displacement and impact load is paramount for SHM because these metrics often provide direct indicators of structural integrity and performance. Displacement measurements can reveal excessive deflection, lateral movement, or longitudinal movement, …

    arizona-thes Repository record for Deep Learning Methods for Impact Load Identification and Displacement Estimation in Structures (opens in a new tab)

  6. Advanced SAR Interferometry Methods for Ground Displacement Estimation from Spaceborne and Airborne Platforms

    … supports improved understanding and advanced estimation methods for the use of PT algorithms in DS interferometry. Another major drawback of traditional InSAR is that only the deformation along the line-of-sight (LOS) direction can be detected. In order to estimate the deformation in the …

    houston Repository record for Advanced SAR Interferometry Methods for Ground Displacement Estimation from Spaceborne and Airborne Platforms (opens in a new tab)

  7. Tuning an output-only dual Kalman filter for displacement estimation from measured accelerations

    Direct measurement of the vertical displacement of bridge superstructures is typically not feasible; therefore, methods to estimate displacement from acceleration measurements exist. Joint input-state estimation techniques based on Kalman-type filters have been used for estimating displacements, …

    umn Repository record for Tuning an output-only dual Kalman filter for displacement estimation from measured accelerations (opens in a new tab)

  8. Development of Novel Energy-Based Displacement Estimation Methods: From Ultrasound Elastography to Super-Resolution Ultrasound

    … is imposed to obtain a unique solution to the displacement estimation problem. Existing energy-based methods consider only amplitude similarity to formulate the data function, which makes the displacement estimation process sensitive to outliers. In addition, they exploit the L2-norm of the …

    concordia Download PDF for Development of Novel Energy-Based Displacement Estimation Methods: From Ultrasound Elastography to Super-Resolution Ultrasound (opens in a new tab)

  9. High Accuracy Non-Contact Measurement Techniques for Torso Displacement and Its Application

    … physiological waveform tracking and torso displacement estimation that may provide stroke volume and pulse pressure information. In this dissertation, high accuracy displacement estimation techniques were investigated. The goal is to obtain feasible methods in accurately estimation of torso …

    hawaii Repository record for High Accuracy Non-Contact Measurement Techniques for Torso Displacement and Its Application (opens in a new tab)

  10. A Two Dimensional Speckle Tracking Method Based on Zero Phase Crossing in Ultrasound

    Displacement estimation in ultrasound is a common yet important task for various applications, including tissue/blood motion estimation, elastography imaging, temperature estimation, and shear wave elasticity imaging. A variety of speckle tracking methods have been proposed for displacement …

    umn Repository record for A Two Dimensional Speckle Tracking Method Based on Zero Phase Crossing in Ultrasound (opens in a new tab)

  11. Direct Estimation of Strains at Carotid Artery Wall Using Autocorrelation of Ultrasound Images

    … of these implementations rely on finding the displacement of tissue in 1D or 2D. In quasi-static elastography, spatial gradients of the axial displacement fields are computed to produce “elasticity maps”, which are overlaid on anatomical B-mode images of the organ, e.g. breast. The quality of …

    umn Repository record for Direct Estimation of Strains at Carotid Artery Wall Using Autocorrelation of Ultrasound Images (opens in a new tab)

  12. Real-time Regularized Tracking of Shear-Wave in Ultrasound Elastography

    … the small tissue motion (referred to as tissue displacement) is a critical step in shear-wave elastography, but is challenging due to various sources of noise in the ultrasound data. I formulate tissue displacement estimation as an optimization problem and propose two computationally efficient …

    concordia Download PDF for Real-time Regularized Tracking of Shear-Wave in Ultrasound Elastography (opens in a new tab)

  13. Ultrasonic viscoelasticity imaging of nonpalpable breast lesions

    … The quality of the strain image produced by displacement estimation algorithms are heavily influenced by the RF echo data recorded by different ultrasound systems. A small clinical study was conducted with 21 women having a single nonpalpable breast lesion, each detected mammographically with …

    uiuc Repository record for Ultrasonic viscoelasticity imaging of nonpalpable breast lesions (opens in a new tab)

  14. Chronic Myocardial Infarct Visualization Using 3D Ultrasound

    … uses a Cramer-Rao lower bound limited displacement estimator. The dissertation then proceeds to develop an implementable method for biased time-delay estimation. Biased time-delay estimation is shown to surpass the traditional limits described by the Cramer-Rao lower bound in a mean …

    duke Repository record for Chronic Myocardial Infarct Visualization Using 3D Ultrasound (opens in a new tab)

  15. Η θέση της αορτής σε σχέση με τη θωρακική μοίρα της σπονδυλικής στήλης, ανάλογα με την θέση του ασθενούς

    … We performed this study in order to evaluate the displacement of the aorta relative to the spine (levels T4 to T12) in patients with scoliotic deformity in supine, prone and prone with padding position. Twenty patients underwent CT scan of the thoracic spine and the minimum distance from the entry …

    greece Repository record for Η θέση της αορτής σε σχέση με τη θωρακική μοίρα της σπονδυλικής στήλης, ανάλογα με την θέση του ασθενούς (opens in a new tab)

  16. Long-Term Vibration Monitoring of the I-35W St. Anthony Falls Bridge

    … due to damage. Another parameter, such as displacement estimates, may be better suited for damage detection, however and effective and accurate routine for such estimates is required. A monitoring system on the I-35W St. Anthony Falls Bridge, which crosses the Mississippi River in …

    umn Repository record for Long-Term Vibration Monitoring of the I-35W St. Anthony Falls Bridge (opens in a new tab)

  17. Distortion Reduction and Signal Estimation in Doppler Radar Physiological Monitoring Systems

    … to overcome distortions and improve signal estimation in wireless vital sign monitoring. Channel imbalance in quadrature receivers is one of the distortion sources that has been systematically investigated, theoretically and experimentally. It has been demonstrated that imbalance can …

    hawaii Repository record for Distortion Reduction and Signal Estimation in Doppler Radar Physiological Monitoring Systems (opens in a new tab)

  18. Cubic-panorama image dataset compression for image-based virtual environment navigation

    … representation, unrestricted search for displacement vectors as well as matching reference blocks is extended beyond side image boundaries in all directions. A block padding algorithm for constructing reference blocks is presented for displacement estimation and compensation. Optimized …

    ottawa-retro Repository record for Cubic-panorama image dataset compression for image-based virtual environment navigation (opens in a new tab)

  19. Peripheral perfusion imaging modeling

    … of normalized cross-correlation (NCC) displacement estimation algorithm and Fourier-based registration methods. The remarkable advantage of image registration methods and their ability to help reduce the bandwidth of coherent clutter motion improves the performance of clutter filter on …

    uiuc Repository record for Peripheral perfusion imaging modeling (opens in a new tab)

  20. Ultrasound Based Soft Tissue Elastic Modulus and Strain Measurement

    … elastography was implemented and novel strain estimation quality assessment approach was proposed to discard noisy strain images. The second study proposed a shear wave generation method, called Dual Push Beam (DPB) to address challenges of the current shear wave elastography techniques, such …

    whiterose Download PDF for Ultrasound Based Soft Tissue Elastic Modulus and Strain Measurement (opens in a new tab)

Page 1 of 2