Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 73 for “"Dissolution profiles"”.
-
Effect of tablet compression on the dissolution of aspirin tablets using a novel off-center paddle impeller (opi) dissolution testing system
In the pharmaceutical industry, dissolution testing is routinely carried out to determine the dissolution rate of oral solid dosage forms. Among several testing devices, the USP Dissolution Apparatus 2 is the device most commonly used. However, despite its widespread use, this apparatus has been …
-
Dissolution of different commercial aspirin tablets using a novel off-center paddle impeller (OPI) dissolution testing system
Dissolution testing is routinely conducted in the pharmaceutical industry to provide in vitro drug release information for quality control purposes. The most common dissolution testing system for solid dosage forms is the United States Pharmacopeia (USP) Dissolution Testing Apparatus 2. In this …
-
Hydrodynamic effects of a cannula in a USP dissolution testing apparatus 2
Dissolution testing is routinely used in the pharmaceutical industry to provide in vitro drug release information for drug development and quality control purposes. The USP Testing Apparatus 2 is the most common dissolution testing system for solid dosage forms. Usually, sampling cannulas are used …
-
Dissolution of disintegrating solid dosage forms in a modified dissolution testing apparatus 2
Dissolution tests are routinely carried out in the pharmaceutical industry to determine the dissolution rate of solid dosage forms. Dissolution testing serves as a surrogate for drug bioavailability through in vitro-in vivo correlation (IVIVR), and it additionally helps in guiding the development …
-
COLLOID-MEDIATED MICROFLUIDIC EMULSION-BASED CRYSTALLIZATION
… microscopic observations. Finally, tunable drug dissolution profiles from these particles are presented. This understanding of the interplay of colloidal ordering and drug crystallization provides insights into the direct manufacture of composite microparticles with tailored compositions, …
-
Fabrication of porous extended-release tablets using dual nozzle fused deposition modeling 3D printing techniques
… respectively in k value (g/ mm3). In vitro dissolution studies were performed in phosphate buffer (pH 6.8) to evaluate the drug release rate of the printed tablets. Due to SEM images, drug load, and other factors, F1 core tablets demonstrated a faster dissolution profile than F2 core …
-
Dissolution testing of prednisone and salicylic acid calibrator tablets at different tablet locations
Dissolution testing is routinely carried out in the pharmaceutical industry to determine the rate of dissolution of solid dosage forms. This test is one of the several tests that pharmaceutical companies typically conduct on oral dosage formulations (e.g., tablets) to determine compliance. The USP …
-
Hydrodynamic effects of an arch-shaped fiber optic probe in a dissolution testing apparatus 2
Dissolution testing is widely used in the pharmaceutical industry to evaluate newly developed drug formulations and as a quality control method to insure that solid dosage forms have consistent dissolution property. Typically, samples are manually drawn from the dissolution vessel prior to …
-
Quality and composition of anthelmintic medicines available in Eastern and Western Africa: an \({in-vitro}\) analysis of Albendazole, Mebendazole and Praziquantel
… pharmacopoeiae, applying assays for dissolution profiles and high-performance liquid chromatography (HPLC). Despite minor irregularities, appearance of the products did not hint at falsified medicines. However, 19.6 % of the brands collected in Ghana and Tanzania were not officially …
-
Pharmaceutical performance testing of commercially available calcium supplements
… by their physical properties, disintegration and dissolution profiles. Physical tests and disintegration did show a pH sensitivity. Disintegration confirmed the good uniformity of the products. In the USP required dissolution test, most of the products did not achieve acceptable drug release in …
-
Dry powder antibiotics for inhaled anti-tuberculosis therapy
… methods were also aimed. A novel dissolution method for evaluating the in vitro dissolution behavior of inhalation formulations was developed. The membrane holder was designed to enclose previously air-classified formulations so that they could be uniformly tested in the …
-
Characterisation and thermodynamic stability of solvated crystal forms of mebendazole
… induced a significant difference in the dissolution profiles of the two forms in 0.1 N HCI at 3T°C (f2 = 16). The powder dissolution profiles of Form D indicated a 51% dissolution whereas Form E revealed a 97% dissolution after 120 minutes. The difference in the dissolution profiles was …
-
Investigating the influence of non-volatile excipients on inhaled drug disposition
… The effect of non-volatile excipient on drug dissolution rate was also assessed by testing prototype MDI formulations with varying excipient amounts (glycerol and isopropyl myristate – IPM) and evaluating <i>in vitro</i> dissolution profiles. Finally, different formulations with and without …
-
Novel Carbopol-Wax Blends for Controlled Release Oral Dosage Forms
… infrared spectrophotometer was used to predict dissolution profiles of propranolol sustained release tablets non-destructively. Three different modeling algorithms were compared for their predictability. K-nearest neighbors algorithm (KNN) yielded models with better predictability compared to …
-
Lubrication In Pharmaceutical Tablet Manufacturing
… leads to deterioration in tablet strength and dissolution. Sodium lauryl sulfate (SLS), Poloxamer 188 and Poloxamer 407 were selected as MgSt-alternative lubricants to be tested in tablet formulations. We found that the lubrication efficiency of these three materials are comparable with MgSt. …
-
Formulation and Evaluation of Oral Film Loaded with Cannabidiol Using Solvent Casting Technique
… endurance, and adequate tensile strength. The dissolution profiles indicated a rapid release of CBD, with more than 85% of the drug released within 15 minutes. The development of CBD-loaded oral film offers several advantages over traditional dosage forms, such as improved patient compliance.
-
In vitro simulation of the human proximal colon to advance biopharmaceutics modelling
… application as an advanced biopharmaceutical dissolution apparatus. The model was improved in terms of robustness, longevity and industry-integratability. The number of motility patterns until failure was increased from < 80 (n = 3) to > 14, 400. Magnetic resonance imaging (MRI) showed that …
-
Development of a biorelevant dynamic model of human proximal colon: a tool for designing colon – specific drug delivery systems
… in vivo data. The hydrodynamics in USP 2 dissolution apparatus were also assessed using Particle Image Velocimetry (PIV) and Planar Induced Fluorescence (PLIF). Areal distribution and individual striation methods showed high mixedness level close to tip. PEPT experiments were performed …
-
Development of Multiple Dosage Forms Using Fused Deposition Modeling 3D Printing Coupled with Hot-Melt Extrusion Dissertation
… retention rate method. Furthermore, the drug dissolution behavior of the bilayer tablets is analyzed to evaluate their performance. In the second chapter, various extended-release tablet models are designed and printed, with a comparative analysis of the dissolution profiles of different …
-
Hydrodynamics, dissolution, and mass transfer effects in different dissolution testing apparatuses and laboratory systems
Dissolution testing apparatuses and shaker flasks agitated by shaker tables are laboratory systems routinely found in many laboratories at most companies and agencies, and especially in pharmaceutical companies. These devices are commonly used in a number of applications, from drug development to …
Page 1 of 4