Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"Dissolved gas analysis"”.

  1. Dissolved Gas Analysis of Insulating Transformer Oil Using Optical Fiber

    … protection systems fail they often generate gas or acoustic signals signifying a problem. Research has already been performed discovering new ways integrate optical fiber sensors into high voltage transformers. This thesis is a continuation of that research by attempting to improve sensor …

    vt Repository record for Dissolved Gas Analysis of Insulating Transformer Oil Using Optical Fiber (opens in a new tab)

  2. Using dissolved gas analysis to investigate the performance of permeable reactive barriers

    … barrier (PRB) treatment materials can lead to gas production, potentially resulting in the formation of gas bubbles and ebullition. For this work degassing in the saturated zone of PRB systems due to the production of gases (primarily CO₂ and CH₄) is investigated using the depletion of Aland …

    ubc Repository record for Using dissolved gas analysis to investigate the performance of permeable reactive barriers (opens in a new tab) Download PDF for Using dissolved gas analysis to investigate the performance of permeable reactive barriers (opens in a new tab)

  3. Enhancing transformer oil dissolved gas analysis using deep learning and ensemble classification

    … and these degradation processes pro- duce gas compounds that are dissolved in its insulating oil. Dissolved gas analysis (DGA) assesses a transformer’s condition by measuring these gasses, and numerous interpretation techniques exist based on physical mechanisms and experimental data to …

    manitoba Repository record for Enhancing transformer oil dissolved gas analysis using deep learning and ensemble classification (opens in a new tab)

  4. Insights into Geyser Behavior: The Role of Non-Condensable Gas

    … to better understand the role of non-condensable gas in geysers. Two case studies were conducted, the first to determine how non-condensable gas may influence the eruption mechanism in hot water systems, and the second to elucidate gas dynamics in a cold water geyser driven by non-condensable gas. …

    calgary Repository record for Insights into Geyser Behavior: The Role of Non-Condensable Gas (opens in a new tab)

  5. Studies of Monitoring and Diagnosis Systems for Substation Apparatus

    … diagnosis tool for power transformers based on dissolved gas analysis, ANNEPS v4.0, was developed. The new tool extended the existing expert system and artificial neural network diagnostic engine with automated data acquisition, display, archiving, and alarm notification functions. This thesis …

    vt Repository record for Studies of Monitoring and Diagnosis Systems for Substation Apparatus (opens in a new tab)

  6. Space weather impacts on ground-based energy infrastructure

    … of transformers in the long term. In this study, dissolved gas data from UK power station transformers were analysed in detail in a space weather context for the first time. Dissolved gas measurements from 2010–2015 were used to look for evidence of a link between degradation of the transformer …

    lancaster Download PDF for Space weather impacts on ground-based energy infrastructure (opens in a new tab)

  7. Greenhouse Gas Production and Nutrient Reductions in Denitrifying Bioreactors

    … production of nitrous oxide, a potent greenhouse gas. Results from a laboratory experiment supported the hypothesis that the addition of biochar, a charcoal-like soil amendment and novel organic carbon source in DNBR research, would increase nitrate and phosphorus removal as well as decrease the …

    vt Repository record for Greenhouse Gas Production and Nutrient Reductions in Denitrifying Bioreactors (opens in a new tab)

  8. Improvements to standards-driven DGA condition monitoring methodologies of oil-immersed transformers

    … a Standard-driven methodology for interpreting Dissolved Gas Analysis (DGA) for condition monitoring of oil-immersed Transformers (TXs). The focus is on analysing and evaluating the methodology outlined in IEEE C57.104-2019, which differs substantially from both its predecessor and its closest …

    strathclyde Repository record for Improvements to standards-driven DGA condition monitoring methodologies of oil-immersed transformers (opens in a new tab)

  9. Fiber Optic Sensors for On-Line, Real Time Power Transformer Health Monitoring

    … the concentration of PD generated combustible gases dissolved in the transformer oil has been proven to be an effective procedure for transformer health state estimation. However current commercially available sensors can only be installed outside of transformers and offer indirect or delayed …

    vt Repository record for Fiber Optic Sensors for On-Line, Real Time Power Transformer Health Monitoring (opens in a new tab)

  10. Feature-weighted MMD-CORAL for domain adaptation in power transformer fault diagnosis

    … crucial for reliable power grid operation. Dissolved Gas Analysis (DGA) has long been recognized as a standard diagnostic technique; however, the diagnostic performance of machine learning models often degrades when applied to new datasets collected under different operational or …

    uvic Repository record for Feature-weighted MMD-CORAL for domain adaptation in power transformer fault diagnosis (opens in a new tab)

  11. Study of Power Transformer Abnormalities and IT Applications in Power Systems

    … been launched for power transformers based on dissolved gas analysis (DGA). The above results and findings can help improving power equipment diagnosis and utility maintenance strategies.

    vt Repository record for Study of Power Transformer Abnormalities and IT Applications in Power Systems (opens in a new tab)

  12. Machine learning for power transformer diagnostics

    … of methods suitable for transformer assessment, dissolved gas analysis (DGA) for oil-filled transformers is an effective and practical approach. Tapped oil sampling enables measurement of gas contamination which renders indices indicative of internal breakdown and faults which affect gas …

    qu-belfast Repository record for Machine learning for power transformer diagnostics (opens in a new tab) Download PDF for Machine learning for power transformer diagnostics (opens in a new tab)

  13. A Data-Driven Framework for Transformer Health Monitoring in Distribution Networks

    … lightning strikes, protection devices employed, dissolved gas analysis (DGA) data, overloading, and phase unbalance etc. To prevent sudden failures of transformers while meeting growing electricity demands, transformer health monitoring and failure prediction become increasingly important in …

    sask Repository record for A Data-Driven Framework for Transformer Health Monitoring in Distribution Networks (opens in a new tab)

  14. An artificial neural network approach to transformer fault diagnosis

    … faults in oil-filled power transformers based on dissolved gas-in-oil analysis. The goal of the research is to investigate the available transformer incipient fault diagnosis methods and then develop an ANN approach for this purpose. This ANN classifier should not only be able to detect the fault …

    vt Repository record for An artificial neural network approach to transformer fault diagnosis (opens in a new tab)

  15. Condition Assessment of Power Transformer Winding Insulation Based on Partial Discharge Detection

    … the insulation system is damaged in two ways: by gases created from the oil and paper, and by degradation of its solid insulation. Solid insulation degradation is correlated with the PD apparent charge value, which is usually measured by conventional PD detectors. However, conventional PD …

    waterloo Repository record for Condition Assessment of Power Transformer Winding Insulation Based on Partial Discharge Detection (opens in a new tab)

  16. An infrared spectrometer based on a MEMS fresnel zone plate for measuring dissolved gases in high voltage equipment

    … voltage (HV) equipment. It does so by measuring dissolved gases within it. These gases include carbon monoxide, carbon dioxide, methane, ethane, ethylene, and acetylene. These gases are currently measured using numerous technologies such as gas combustion, gas chromatography, photoacoustic …

    manitoba Repository record for An infrared spectrometer based on a MEMS fresnel zone plate for measuring dissolved gases in high voltage equipment (opens in a new tab)

  17. Příspěvek k hodnocení plynů rozpuštěných v oleji při diagnostice výkonových olejových transformátorů

    Disertační práce je zaměřena na hodnocení plynů rozpuštěných v oleji při diagnostice výkonových olejových transformátorů. Vychází ze známých, v normách, předpisech a literatuře uvedených skutečností a tyto doplňuje o nové poznatky. Jedná se především o stanovení plynů, které stačí znát pro …

    brno-tech Repository record for Příspěvek k hodnocení plynů rozpuštěných v oleji při diagnostice výkonových olejových transformátorů (opens in a new tab)