Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 72 for “"Distribution transformers"”.

  1. Optimal Preventive Maintenance for Small Distribution Transformers

    Since small distribution transformers fail in a stochastic fashion, the exact time of failure is not known. If the cost of replacing an unfailed transformer is less than the cost of replacing a failed transformer it is advantageous to replace the transformer before failure (preventive maintenance). …

    clemson Repository record for Optimal Preventive Maintenance for Small Distribution Transformers (opens in a new tab)

  2. Economic analysis of distribution transformers under harmonic distortion

    … how much of total transformer losses in the distribution system of Sweden is due to harmonic losses, in comparison to the remaining other losses. Use of non-linear loads in power systems is increasing, and this has become a power quality problem for both electric companies and customers. …

    chalmers Repository record for Economic analysis of distribution transformers under harmonic distortion (opens in a new tab)

  3. Smart Grid Distribution Transformers: Empirical Design and Dynamic Load Management

    … vehicles and distributed generation into distribution networks gives rise to higher, more volatile and bi-directional energy flows through distribution transformers. Consequently, improved distribution transformer design and monitoring approaches are required to minimise future capital …

    auckland-tech Repository record for Smart Grid Distribution Transformers: Empirical Design and Dynamic Load Management (opens in a new tab)

  4. Power system harmonic effects on losses and temperature rise in distribution transformers.

    … magnitude and frequency. In the power grid, transformers are the key components which interconnect different parts of the system at different operating voltage levels. Harmonic contamination in the electricity networks can generate excessive losses and associated temperature rise in …

    unsw Repository record for Power system harmonic effects on losses and temperature rise in distribution transformers. (opens in a new tab)

  5. Economic and Technical Feasibility of Vapor Phase Cooling of Pole-Top Distribution Transformers

    … feasibility of vapor phase cooling of pole type transformers. Two of the schemes tested resulted in significantly lower coil temperatures: a) core/coil totally immersed in Freon 113 and b) a small quantity of Freon 113 with a gravity distribution system. Very good agreement existed between …

    marquette Repository record for Economic and Technical Feasibility of Vapor Phase Cooling of Pole-Top Distribution Transformers (opens in a new tab)

  6. Protection Against Ungrounded Single Phase Open Circuit Faults in 3-Phase Distribution Transformers

    … explores the impacts and behavior of 3-phase distribution transformers when subject to ungrounded single phase open circuit faults. A simple 3-phase system is modeled using MATLAB Simulink and operation under fault conditions are simulated and studied. Simulation results are confirmed via lab …

    calpoly Repository record for Protection Against Ungrounded Single Phase Open Circuit Faults in 3-Phase Distribution Transformers (opens in a new tab)

  7. An investigation into the occurrence of ferroresonance in small distribution transformers in South Africa

    … overvoltages during the commissioning phase of distribution transformers. Consequently, resonance was reported as the cause of overvoltages on the secondary winding when the expected voltage was 0 V. Recent changes to the SANS 780 standard mandated a reduction in distribution transformer core …

    nwu-za Repository record for An investigation into the occurrence of ferroresonance in small distribution transformers in South Africa (opens in a new tab)

  8. Importance of Detailed Modeling of Loads/PV Systems Connected to Secondary of Distribution Transformers

    … share of these installations are downstream of distribution transformers and thus connected to the secondary. To precisely analyze voltage variations induced by PV systems into distribution systems, accurate models of load and PV systems connected to the secondary side of distribution …

    vt Repository record for Importance of Detailed Modeling of Loads/PV Systems Connected to Secondary of Distribution Transformers (opens in a new tab)

  9. Heterogeneous modelling and adaptive fuzzy logic control of energy efficient three phase switchable distribution transformers

    This thesis investigates concurrent executable multiple method modelling techniques of an energy efficient transformer and automatic efficiency optimised fuzzy logic control method. The modelling framework includes electrical characteristics, adaptive fuzzy logic controller, temperature rise, by …

    adelaide Repository record for Heterogeneous modelling and adaptive fuzzy logic control of energy efficient three phase switchable distribution transformers (opens in a new tab)

  10. Probabilistic impact of charging plug-in electric vehicles on the electric energy distribution systems

    … grid including generation, transmission, and distribution system usually serving the loads in the consumer’s side through distribution transformers. Generally, increasing the demand requires increasing the supply and therefore any increasing in the consumer’s side must be covered and delivered …

    uoit Repository record for Probabilistic impact of charging plug-in electric vehicles on the electric energy distribution systems (opens in a new tab)

  11. Analysis and evaluation of transactive energy control in active distribution systems

    The electric power distribution system is experiencing significant operational changes due to the integration of plug-in electric vehicles and intermittent distributed energy resources such as rooftop solar photovoltaics. As plug-in electric vehicle charging represents a significant increase in …

    uoit Repository record for Analysis and evaluation of transactive energy control in active distribution systems (opens in a new tab)

  12. A New Approach to Assessment and Utilisation of Distribution Power Transformers

    … utilise several voltage levels using power transformers to transfer voltages and connect parts of the power system with different voltage levels. One of these voltage transformations is being performed in the key component of the electrical power system: the distribution power transformer. …

    vu-aus Download PDF for A New Approach to Assessment and Utilisation of Distribution Power Transformers (opens in a new tab)

  13. Last Mile Asset Monitoring: Low Cost Rapid Deployment Asset Monitoring

    Installation and utilization of residential distribution transformers has not changed substantially over a long period of time. Utilities typically size their transformers based on a formula that takes into account broadly what types and how many dwellings will be connected. Most new residential …

    portland-state Repository record for Last Mile Asset Monitoring: Low Cost Rapid Deployment Asset Monitoring (opens in a new tab)

Page 1 of 4