  1. Competitiveness of district cooling in energy efficient supermarkets

    This thesis concerns utilization of district cooling in supermarkets. Today, district cooling is primarily used in hotels, hospitals, offices and computer centrals. This study investigates the possibility to expand the range of customers to also include supermarkets. The studied use includes …

    chalmers Repository record for Competitiveness of district cooling in energy efficient supermarkets (opens in a new tab)

  2. Unlocking district cooling potential by means of design optimization

    L'abstract è presente nell'allegato / the abstract is in the attachment

    poli-torino Repository record for Unlocking district cooling potential by means of design optimization (opens in a new tab)

  3. Optimization modeling of the district cooling system in Gothenburg

    Göteborg Energi is the sole provider of district cooling in Gothenburg. The district cooling system (DCS) is currently expanding with an increase in the installed capacity of the chillers. The installed capacity of chillers in 2030 will be double the current capacity. Besides, a thermal energy …

    chalmers Repository record for Optimization modeling of the district cooling system in Gothenburg (opens in a new tab)

  4. Data driven analysis of district cooling substations for performance diagnosis

    District cooling (DC) is a crucial technology for providing cooling for purposes such as space cooling for indoor environment, industrial processes, food storage industry. To improve the efficiency of the district cooling system (DCS) periodic maintenance of the components in the system is …

    chalmers Repository record for Data driven analysis of district cooling substations for performance diagnosis (opens in a new tab)

  5. Ice slurry storage system in district cooling application for air-conditioning

    … and the circulation of this ice slurry for space cooling application were investigated. Three types of spray nozzles: a shower spray, a fountain spray and nozzle from the bottom were used for ice slurry production. It was found that, for 3.025 kg of ice formation, time needed was about 35 min, 50 …

    nus Repository record for Ice slurry storage system in district cooling application for air-conditioning (opens in a new tab) Download file for Ice slurry storage system in district cooling application for air-conditioning (opens in a new tab)

  6. Hydraulic Modeling of Large District Cooling Systems for Master Planning Purposes

    District Cooling Systems (DCS) have been widely applied in large institutions such as universities, government facilities, commercial districts, airports, etc. The hydraulic system of a large DCS can be complicated. They often stem from an original design that has had extensive additions and …

    tamu Repository record for Hydraulic Modeling of Large District Cooling Systems for Master Planning Purposes (opens in a new tab)

  7. Integrated framework for modeling and optimization of commercial district cooling systems

    The cooling of buildings drives the peak electric demand in the summer, and the cost associated with this peak demand can significantly increase the summer electric bill for many commercial buildings. Modeling and optimization of heating, ventilating, and air-conditioning (HVAC) systems in …

    colo-mines Repository record for Integrated framework for modeling and optimization of commercial district cooling systems (opens in a new tab)

  8. Understanding the role of thermal energy storage on district cooling performance

    Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2024-09-16 without embargo terms

    uiuc Repository record for Understanding the role of thermal energy storage on district cooling performance (opens in a new tab)

  9. Understanding the role of thermal energy storage on district cooling performance

    Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2024-09-16 without embargo terms

    uiuc Repository record for Understanding the role of thermal energy storage on district cooling performance (opens in a new tab)

  10. Integrated System Architecture Development and Analysis Framework Applied to a District Cooling System

    … framework, a case study consisting of a complex district cooling system is implemented. The case study shows the framework’s capabilities in enabling the successful modeling of a complex district cooling system. The system architecture model was developed using SysML and the engineering analysis …

    iupui Repository record for Integrated System Architecture Development and Analysis Framework Applied to a District Cooling System (opens in a new tab)

  11. Developing a Decision Making Approach for District Cooling Systems Design using Multi-objective Optimization

    … In recent years, the demand for urban or district cooling technologies and networks has been increasing significantly as an alternative to conventional systems due to their higher efficiency and improved ecological impact. However, to obtain an efficient design for district cooling systems …

    qucosa-diss

  12. Data-driven Modelling and Optimized Management of the District Cooling System and Thermal Energy Storage in Gothenburg

    District cooling system (DCS) is a sustainable and cost-effective way to provide cooling energy in urban areas[1]. DCS is growing in Sweden due to the increase in cooling energy demand. In Gothenburg, an expansion of DCS will be done by installing more cooling units and a cold-water thermal energy …

    chalmers Repository record for Data-driven Modelling and Optimized Management of the District Cooling System and Thermal Energy Storage in Gothenburg (opens in a new tab)

  13. Urban Building Energy Models for District Cooling: A Data-Driven Approach Considering Building and Occupant Behavior Dynamics

    District cooling offers an energy-efficient solution for hot urban regions where cooling demands are high. Accurate and rapid predictions of cooling requirements are vital during the planning phase to support informed decision-making. Surrogate models, which combine physics-based simulations with …

    concordia Download PDF for Urban Building Energy Models for District Cooling: A Data-Driven Approach Considering Building and Occupant Behavior Dynamics (opens in a new tab)

  14. Optimization through Automated Decision Support in District Cooling - Minimizing Electricity Use through Software-Based Start/Stop Control and Chiller Dispatch

    … support can improve operational efficiency in district cooling through automated start/stop control and chiller dispatch. The study was conducted as a design science case study at Göteborg Energi’s district cooling network in Gothenburg, Sweden. The work addresses three main questions: …

    chalmers Repository record for Optimization through Automated Decision Support in District Cooling - Minimizing Electricity Use through Software-Based Start/Stop Control and Chiller Dispatch (opens in a new tab)

  15. Decentralized Thermal Energy Storage for District Cooling: A techno-economic case study on the feasibility of small scale latent thermal energy storage in Gothenburg

    District cooling (DC) networks are expanding. To accommodate future network ex pansion and mitigate increasing peak demand, thermal energy storage (TES) can be incorporated into the DC networks. Decentralized storage has the potential to re lieve production and network capacity during peak demand …

    chalmers Repository record for Decentralized Thermal Energy Storage for District Cooling: A techno-economic case study on the feasibility of small scale latent thermal energy storage in Gothenburg (opens in a new tab)

  16. Development and assessment of renewable ammonia and methanol production systems

    … plant integrated with an ammonia production and district cooling system. Two different operation cases of the analyzed system are considered, where for the first case 50% of the power produced is used to produce ammonia as an energy storage medium. The second case considers the power production …

    uoit Repository record for Development and assessment of renewable ammonia and methanol production systems (opens in a new tab)

  17. Análise do resfriamento distrital

    … other studies, this survey intends to analyze a district cooling system through the exergoeconomic perspective, giving the chilled water stream a levelized cost per unit of exergy and comparing it with another costing methodology. It considers the implementation of this centralized cooling supply …

    brazil-uerj Repository record for Análise do resfriamento distrital (opens in a new tab)

  18. Predicting cooling loads in hot and humid climates using machine-learning approaches

    ABSTRACT Predicting cooling loads in hot and humid climates using machine-learning approaches Bingyan Jia In residential, buildings cooling accounts for a significant amount of energy in hot, humid areas. In Qatar, cooling accounts for more than 60% of the country’s generated electricity. In …

    concordia Download PDF for Predicting cooling loads in hot and humid climates using machine-learning approaches (opens in a new tab)

  19. URBAN TEXTURE ANALYSIS AND ITS RELATION TO BUILDING ENERGY CONSUMPTION

    … has been conducted to observe its effect on district energy performance. These parametric study scenarios, which focus on non-domestic function, are simulated using Integrated Environmental Solutions to study the identified urban texture related to district cooling load and external heat …

    nus Repository record for URBAN TEXTURE ANALYSIS AND ITS RELATION TO BUILDING ENERGY CONSUMPTION (opens in a new tab) Download file for URBAN TEXTURE ANALYSIS AND ITS RELATION TO BUILDING ENERGY CONSUMPTION (opens in a new tab)