Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 9 of 9 for “"Doehlert design"”

  1. Aplicação de ferramentas estatísticas para avaliação de filmes de emulsões estireno acrílicas

    … is focused on using statistical tools (Design of Experiments, DOE) and Principal Component Analysis (PCA) for evaluating latex film formation. The experimental part was conducted at Dow Brasil R&D facility in São Paulo. Samples were analyzed in triplicate using the following tests: scrub …

    brazil-ufscar Repository record for Aplicação de ferramentas estatísticas para avaliação de filmes de emulsões estireno acrílicas (opens in a new tab)

  2. Uso da técnica laser-induced breakdown spectroscopy (LIBS) para análise direta de ligas metálicas: estratégias de normalização, calibração univariada e multivariada e modelos de classificação

    … parameters of the LIBS equipment was done using Doehlert design, varying the laser energy in 7 levels (30 to 80 mJ), delay time in 5 levels (0 to 2 μs) and spot size in 3 levels (50 to 150 μm). The chosen compromise condition was 60 mJ of energy, 0.9 μs of delay time and 100 μm of spot size, …

    brazil-ufscar Repository record for Uso da técnica laser-induced breakdown spectroscopy (LIBS) para análise direta de ligas metálicas: estratégias de normalização, calibração univariada e multivariada e modelos de classificação (opens in a new tab)

  3. Determinação sequencial rápida de As e Sb, Bi e Pb por espectrometria de absorção atômica com geração de hidretos

    … and NaBH4. For these studies it was employed Doehlert design to select the best work conditions and obtain more information of the proposed methods. Some analytical parameters were obtained, respectively, for As, Sb, Bi and Pb: Limits of detection (LOD) (0.15; 0.16; 0.60 e 0.77 μg L-1), …

    brazil-ufscar Repository record for Determinação sequencial rápida de As e Sb, Bi e Pb por espectrometria de absorção atômica com geração de hidretos (opens in a new tab)

  4. Estudo da degradação do pesticida atrazina através da redução por cobre de valência zero, e da sua potencialidade como pré-etapa à foto-oxidação com persulfato

    … conditions in the pre-reducing step, a Doehlert experimental design was followed. Then, the mineralization of the solution that presented the highest ATZ degradation was studied by varying the oxidant concentration – sodium persulfate (1, 5 and 10 mmol L-1 ) – and the UV source of …

    brazil-ufrn Repository record for Estudo da degradação do pesticida atrazina através da redução por cobre de valência zero, e da sua potencialidade como pré-etapa à foto-oxidação com persulfato (opens in a new tab)

  5. Development of automatic methods for trace metals determination using on-line separation and preconcentration techniques coupled with atomic spectrometry

    … trace amount of cadmium. A simple manifold was designed and optimized offering several advantages over the conventional on-line liquid-liquid extraction (LLE) systems as well as it enhances the prestige of automated solvent extraction techniques. In this method the sample was mixed on-line with …

    greece Repository record for Development of automatic methods for trace metals determination using on-line separation and preconcentration techniques coupled with atomic spectrometry (opens in a new tab)

  6. Microfluidic high-content phenotypic screening on a Caenorhabditis elegans model

    … enabled by microfluidic devices conveniently designed. First, I propose a strategy to track different phenotypic traits of individual worms over their life cycle. Phenotypes - as duration of the different developmental stages, length, diameter and fluorescent stress response at each …

    epfl Repository record for Microfluidic high-content phenotypic screening on a Caenorhabditis elegans model (opens in a new tab)

  7. Valorisation of vineyard pruning residues into CO2-activated biochar: optimisation, modelling, and application in fixed-bed columns for pesticide removal from water

    … pesticide removal from water, using experimental design to investigate 14 relevant variables and targeting acetamiprid (ACE), metalaxyl (MET) and penconazole (PEN). The study is complemented by comprehensive physicochemical characterisation, kinetic, isotherm, and breakthrough curve modelling, …

    barcelona Repository record for Valorisation of vineyard pruning residues into CO2-activated biochar: optimisation, modelling, and application in fixed-bed columns for pesticide removal from water (opens in a new tab) Embargoed

  8. Otimização multivariada dos parâmetros cromatográficos para determinação de furfural em vinho branco por CLAE-DAD

    … the Surface response Methodology based on the Doehlert matrix. Three variables were selected for optimization: the flow rate of mobile phase, the temperature of analytical column and the proportion of water, in relation to acetonitrile, in the mobile phase. Different responses were tested for …

    brazil-uff Repository record for Otimização multivariada dos parâmetros cromatográficos para determinação de furfural em vinho branco por CLAE-DAD (opens in a new tab)

  9. Ferramentas quimiométricas aplicadas na avaliação de estratégias que visam a remoção de íons fluoreto em efluente de drenagem ácida de mina

    … Dosage, by means of fractional factorial design for each material (5 x 23-1 ). Then, with the variables and materials selected, the work was directed to obtain a response surface that allowed identifying the optimum working region, considering the responses: final fluoride concentration, …

    brazil-ufscar Repository record for Ferramentas quimiométricas aplicadas na avaliação de estratégias que visam a remoção de íons fluoreto em efluente de drenagem ácida de mina (opens in a new tab)