High-Strain Rate Tensile Characterization Of Graphite Platelet Reinforced Vinyl Ester Based Nanocomposites Using Split-Hopkinson Pressure Bar
… Hopkinson Pressure Bar (SHPB) technique. The specimen geometry for tensile test is parametrically optimized by Finite Element Analysis (FEA) using ANSYS Mechanical APDL®. Uniform stress distribution within the specimen gage length has been verified using high-speed digital photography. The …
-
Fretting fatigue Behaviour of Inconel 718 at room and high Temperature
… used, consisting of a rectangular cross-section "dog-bone" specimen pressed against a cylindrical pad. The setup was assembled using a device commonly referred to as a “fretting bridge.” Both plain fatigue and fretting fatigue tests were carried out under different levels of axial and normal load, …
-
Multiscale Behavior of Fused Deposition Additively Manufactured Thermoplastic Cellular Materials
… simultaneously throughout the cross section of a dog bone specimen when the macro crazing threshold stress was reached. AM ABS crazes were an order of magnitude wider with an average width of 100 μm and appeared at one or two locations when the macro crazing threshold stress was reached. Further …
-
Elevated Temperature Formability of Precipitation Hardenable Sheet Aluminum Alloys
… Both alloys were tested using a 76.2 mm wide dog-bone specimen geometry in a Nakazima-type test, that produced near plane-strain conditions. For AA6013-T6, when characterized using the ECM, warm forming did not offer a meaningful improvement in formability with increasing temperature over the …
-
Tensile-tensile fatigue testing and fatigue properties of quasi-unidirectional non-crimp fabric reinforced glass-fibre/epoxy laminates
… devoted to the development of an applicable test specimen configuration for tensile-tensile fatigue testing of the laminates. This is necessary because standard rectangular specimens tend to fail at the tab area, resulting in unrealistic fatigue life predictions. The thesis further focuses on the …
-
The Effects of Laser Shock Peening on the Fatigue Life of Additive Manufactured AlSi10Mg
… peening effects the low cycle fatigue life of AM specimens. The first part of this work was to determine the residual stresses that were created on an AM AlSi10Mg sample from femto-second laser shock peening (LSP). The residual stress was quantified to have a maximum compressive residual stress on …
-
Failure of Rock at Low Mean Stress
… evaluate rock failure at low mean stress using dog-bone specimens of (dry) Dunnville sandstone. Results from these special triaxial extension tests were used in conjunction with conventional triaxial extension and compression experiments with right-circular cylinders to evaluate four failure …