Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 35 for “"Dogbone"”.

  1. Bing's dogbone space and curtis' conjecture

    Bing's dogbone space D is an upper semi continuous decomposition space of E³ which fails to be E³ although the associated decomposition consists only of points and tame arcs. It has proved difficult to find topological properties of D which distinguish it from E³. In this paper, we prove a …

    ubc Repository record for Bing's dogbone space and curtis' conjecture (opens in a new tab) Download PDF for Bing's dogbone space and curtis' conjecture (opens in a new tab)

  2. Comparison of As-built FEA Simulations and Experimental Results for Additively Manufactured Dogbone Geometries.

    … the experimental tests of actual FDM parts. A dogbone geometry is used as a test specimen for the study, with a set of different infill patterns. A displacement controlled tensile test is conducted using these specimens to obtain the experimental stress-strain results. Further, as built 3D CAD …

    clemson Repository record for Comparison of As-built FEA Simulations and Experimental Results for Additively Manufactured Dogbone Geometries. (opens in a new tab)

  3. Evaluation of fiber-matrix interfacial shear strength in fiber reinforced plastics

    … one to seven fibers in the center of polymer dogbone specimens that were tested in tension to determine critical fiber lengths. Those values were used in a new theoretical treatment (that combines stress gradient shear-lag theory with Weibull statistics) to evaluate "interfacial shear …

    vt Repository record for Evaluation of fiber-matrix interfacial shear strength in fiber reinforced plastics (opens in a new tab)

  4. Evaluation of Information Entropy from Acoustic Emission Waveforms as a Fatigue Damage Metric for Al7075-T6

    … fatigue experiments were performed with dogbone samples of aluminum alloy, Al7075-T6, a commonly used material in aerospace structures. Unlike previous studies in which fatigue damage is simply measured based on visible crack growth, this work investigated fatigue damage prior to crack …

    maryland Repository record for Evaluation of Information Entropy from Acoustic Emission Waveforms as a Fatigue Damage Metric for Al7075-T6 (opens in a new tab)

  5. Experimental Investigation of the Mechanical Properties and Auxetic Behavior of Iron-Gallium Alloys

    … tensile testing of single-crystal Galfenol dogbone-shaped specimens and through resonant ultrasound spectroscopy (RUS) of small parallelepiped samples.

    maryland Repository record for Experimental Investigation of the Mechanical Properties and Auxetic Behavior of Iron-Gallium Alloys (opens in a new tab)

  6. Static Response and Failure Analysis of Anisotropic Parts Printed using Fused Filament Fabrication

    … tests were performed on custom-dimensioned PEEK dogbone coupons across multiple material orientations and print rasters. Digital Image Correlation enabled full-field strain measurement across coupon surfaces and a "Strain Tornado" method was developed to interpret locally oriented strains. This …

    washington Repository record for Static Response and Failure Analysis of Anisotropic Parts Printed using Fused Filament Fabrication (opens in a new tab)

  7. A loss tangent measurement surface for free space focused beam characterization of low-loss dielectrics

    … to the LTMS are presented; a reconfigurable dogbone metasurface incorporating varactor diodes to change the resonant frequency is designed using hybrid full-wave / circuit simulations and ECM techniques, showing good model-measurement agreement. Global optimization of metasurfaces using the …

    gatech Repository record for A loss tangent measurement surface for free space focused beam characterization of low-loss dielectrics (opens in a new tab)

  8. Exploration of Additively manufactured Microcellular PLA

    … strength when compared to untreated 3D printed dogbone samples of tensile strength ~50MPa. These findings contribute to understanding the limitations and potential improvements in the mechanical properties of 3D printed PLA for industrial applications.

    washington Repository record for Exploration of Additively manufactured Microcellular PLA (opens in a new tab)

  9. Microscale and ultrafast high cycle fatigue testing of titanium

    … method. Using finite element modelling (FEM) a dogbone type mesoscale cantilever specimen was designed, that facilitated the shift of stress concentrations from sharp corners in a simple initial cantilever design to the centre of a beam. This ensured that failure was more dependent on …

    oxford Repository record for Microscale and ultrafast high cycle fatigue testing of titanium (opens in a new tab)

  10. Microstructural Investigation of the Influence of Geometry on the Mechanical Reliability of Additively Manufactured Metals

    … less well known. In this work, a novel thin-wall dogbone geometry was utilized to study one type of complex geometry observed in a large portion of AM focused designs. The mechanical behavior of these samples was collected through a custom micro-tensile load frame utilizing digital image …

    uky-thes Repository record for Microstructural Investigation of the Influence of Geometry on the Mechanical Reliability of Additively Manufactured Metals (opens in a new tab)

  11. High Resolution X-ray Tomography of Fiber Reinforced Polymeric Composites

    … dimensional volume. In addition, glass fiber dogbone specimens were tested on a miniature tensile machine using x-ray tomography to view deformation of the samples in high resolution. Fractures in the chopped glass composite were observed for x-ray microscopy showing the dominant failure …

    ut-knoxville Repository record for High Resolution X-ray Tomography of Fiber Reinforced Polymeric Composites (opens in a new tab)

  12. Microstructure and texture controlled mechanical behaviour of aluminium processed by static and dynamic severe plastic deformation

    … and uniaxial tensile testing of miniature dogbone-shaped samples. Three-dimensional digital image correlation was employed to acquire the information on local full-field strain maps for the deforming miniature tensile samples. Next, the experimental true stress-true strain data was modelled …

    ghent Repository record for Microstructure and texture controlled mechanical behaviour of aluminium processed by static and dynamic severe plastic deformation (opens in a new tab)

  13. Localized Magnetic Fluid Finishing of Freeform Surfaces Using Electro-Permanent Magnets and Magnetic Concentration

    … the surface roughness of 3D printed polyurethane dogbone samples. The process was capable of reducing the SA values from 11 µm initially to .7 µm. 1 Parts of the abstract are reprinted with permission from “Localized magnetic fluid finishing of freeform surfaces using electropermanent magnets and …

    tamu Repository record for Localized Magnetic Fluid Finishing of Freeform Surfaces Using Electro-Permanent Magnets and Magnetic Concentration (opens in a new tab)

  14. Transformation Induced Fatigue of Ni-Rich NiTi Shape Memory Alloy Actuators

    … life. In this study, as-received and polished at dogbone SMA specimens underwent transformation induced fatigue testing at constant loading. The constant applied loading ranged from 100 MPa to 200 MPa. Specimens were thermally cycled through complete actuation (above Af to below Mf ) by Joule …

    tamu Repository record for Transformation Induced Fatigue of Ni-Rich NiTi Shape Memory Alloy Actuators (opens in a new tab)

  15. Tensile Testing of Cold-Applied Joint Sealants

    … 3, between 1" x 1" x 3" Portland Cement Concrete dogbone-shape samples and 0.2" x 1" x 3" glass substrate samples were prepared according to VTM 90 and ASTM C1135, respectively. The tests were carried out employing an Instron Tensile Testing Machine and unique fixtures designed at Virginia Tech to …

    vt Repository record for Tensile Testing of Cold-Applied Joint Sealants (opens in a new tab)

  16. An automated nondestructive inspection approach to characterize raster orientation and missing extrudate for fused filament fabrication manufacturing.

    … tests are conducted using FFF manufactured dogbone specimens to evaluate the impact of missing extrudate on the strength of the additively manufactured components. For each of the inspected samples, the density-based clustering approach accurately identified the missing extrudate cluster and …

    baylor Repository record for An automated nondestructive inspection approach to characterize raster orientation and missing extrudate for fused filament fabrication manufacturing. (opens in a new tab)

  17. Hybrid Steel Fibre Reinforced Concrete in Shear: From the Material to the Structural Level

    … the material level, tests on cubes, cylinders, dogbones and prisms under bending were performed. A novel dogbone configuration suitable for FRC was also developed. The benefits of fibre hybridization on the shear behaviour and cracking properties of HySFRC with conventional steel reinforcement …

    toronto-retro Repository record for Hybrid Steel Fibre Reinforced Concrete in Shear: From the Material to the Structural Level (opens in a new tab)

  18. Mechanical Analysis of Bacterial Nanocellulose for Biomedical Applications

    … testing. Ten-sile tests were conducted using dogbone shape test strips and a video extensometer. Phys-ical compression of a BNC hydrogels not only removes water from the gel but also in-duces hydrogen bonding between cellulose fibers. Results showed that both the ultimate strength of material …

    uab Repository record for Mechanical Analysis of Bacterial Nanocellulose for Biomedical Applications (opens in a new tab)

  19. Tensile Mechanics of the Knee Meniscus in the Context of Cracks: Failure and Fracture Mechanisms, Strain Concentrations, and the Effect of Specimen Shape

    … than rectangle specimens, and, likely, dogbone specimens. Mechanical effects of meniscus cracks were quantified by comparing cracked and crack-free specimens in circumferential and radial tension. The cracks did not cause a decrease in peak stress, indicating fracture did not occur. …

    penn Repository record for Tensile Mechanics of the Knee Meniscus in the Context of Cracks: Failure and Fracture Mechanisms, Strain Concentrations, and the Effect of Specimen Shape (opens in a new tab)

  20. A Physical Hash for Preventing and Detecting Cyber-Physical Attacks in Additive Manufacturing Systems

    … A second case study is also presented wherein dogbone tensile test coupons were manufactured on a material extrusion system at different extrusion temperatures. This process parameter is an example of a setting that can be maliciously modified and have an effect on the final part strength …

    vt Repository record for A Physical Hash for Preventing and Detecting Cyber-Physical Attacks in Additive Manufacturing Systems (opens in a new tab)

Page 1 of 2