  1. The application of laser doppler technique to vibration measurement and position control.

    The laser Doppler interferometer reported here was developed to investigate the possibilities of remote vibration and motion measurements. The method is noncontacting and operates with unprepared targets, using the diffusely scattered light to measure the axial component of the motion. A full …

    bournemouth Download PDF for The application of laser doppler technique to vibration measurement and position control. (opens in a new tab)

  2. Correlation of geomagnetic field changes with ionospheric motions determined by a doppler technique

    … field at the earth's surface are correlated with doppler measurements. The doppler shift in the frequency of a radio wave travelling in the ionosphere measures the change in refractive index with respect to time, integrated along the wave's path. For a vertical path the integrated change in …

    ubc Repository record for Correlation of geomagnetic field changes with ionospheric motions determined by a doppler technique (opens in a new tab) Download PDF for Correlation of geomagnetic field changes with ionospheric motions determined by a doppler technique (opens in a new tab)

  3. Evaluation of myocardial function in patients with hypertrophic obstructive cardiomyopathy by tissue doppler technique

    … available conventional echocardiographic techniques are semi-quantitative and are limited for a precise quantification of ventricular segmental contractile function. The new TDI, strain rate and strain potentially allow the measurement of myocardial motion and deformation. The regional …

    fu-berlin Repository record for Evaluation of myocardial function in patients with hypertrophic obstructive cardiomyopathy by tissue doppler technique (opens in a new tab)

  4. Εκτίμηση της τμηματικής διαστολικής λειτουργίας του μυοκαρδίου της αριστεράς κοιλίας, με την τεχνική του Doppler μυοκαρδίου (Tissue Doppler Technique)

    … is limited, because of invasive and expensive techniques. The application of echocardiography, after a suitable adaptation in hardware and software, could be evaluate non invasively, easily and with a low cost, the regional diastolic function. The use of color-coded Doppler, named as Tissue …

    greece Repository record for Εκτίμηση της τμηματικής διαστολικής λειτουργίας του μυοκαρδίου της αριστεράς κοιλίας, με την τεχνική του Doppler μυοκαρδίου (Tissue Doppler Technique) (opens in a new tab)

  5. Quantitative Monitoring of Tissue Fractionation by Cavitation-Based High-Intensity Focused Ultrasound

    … bubbles was investigated based on ultrasound Doppler technique. The research focuses on two main HIFU regimes that induce mechanical tissue fractionation: less destructive pulsed HIFU (pHIFU) and boiling histotripsy (BH), each with distinct mechanism of inducing cavitation and varying level of …

    washington Repository record for Quantitative Monitoring of Tissue Fractionation by Cavitation-Based High-Intensity Focused Ultrasound (opens in a new tab)

  6. A study of circular couette flow by laser doppler measurement techniques

    A laser Doppler velocimeter is constructed and used to make flow measurements in circular Couette flow. The flow is created between concentric cylinders with a small gap-to-radius ratio, and measurements of the velocity profiles are made in both laminar and turbulent flow regimes. Distortion due to …

    ubc Repository record for A study of circular couette flow by laser doppler measurement techniques (opens in a new tab) Download PDF for A study of circular couette flow by laser doppler measurement techniques (opens in a new tab)

  7. ΑΙΜΟΔΥΝΑΜΙΚΗ ΜΕΛΕΤΗ ΦΛΕΒΟΠΑΘΕΙΩΝ

    … AS INVESIVA (PHLEBOGRAPHY) AND NON- INVASIVE (DOPPLER TECHNIQUE AND IMPEDANCE PLETHYSMOGRAPHY (I.P.G.), IN ORDER TO INVESTIGATE OUR CASES. A COMPARATIVE ASSESSMENT OF THERESULTS OF THE NON-INVASIVE DIAGNOSTIC METHODS WAS MADE AFTER TAKING UNDER CONSIDERATION THE PHLEBOGRAPHIC FINDINGS. THE …

    greece Repository record for ΑΙΜΟΔΥΝΑΜΙΚΗ ΜΕΛΕΤΗ ΦΛΕΒΟΠΑΘΕΙΩΝ (opens in a new tab)

  8. Drop Size and Velocity Distributions in Sprays, A New Approach Based on the Maximum Entropy Formalism

    … made in a simple water spray using the Phase / Doppler technique to obtain the joint size / velocity PDF. Photographic measurements were used to obtain an estimate of the geometry of the breakup region . Good agreement was found between the measurements and the predictions, except in the region …

    waterloo Repository record for Drop Size and Velocity Distributions in Sprays, A New Approach Based on the Maximum Entropy Formalism (opens in a new tab)

  9. Καθορισμός κριτηρίων διάγνωσης και παρακολούθησης του ενδοβολβικού μελανώματος με τις σύγχρονες απεικονιστικές μεθόδους

    … melanomas vascularity was studied using color Doppler technique. Computed Tomography was superior to the other two modalities in demonstrating bony structures and calcifications. It holds an important role in the imaging of retrobulbar space, while tumor density measurements offered valuable …

    greece Repository record for Καθορισμός κριτηρίων διάγνωσης και παρακολούθησης του ενδοβολβικού μελανώματος με τις σύγχρονες απεικονιστικές μεθόδους (opens in a new tab)

  10. An Experimental Investigation of Dilute Slurry Sedimentation

    … Particle velocities were measured by the laser Doppler technique; particle concentrations were measured by local scattered light intensity and by optical transmittance.</p> <p>Steady-state settling velocities as much as 70 percent higher than the average particle Stokes velocity occurred at …

    mcmaster Repository record for An Experimental Investigation of Dilute Slurry Sedimentation (opens in a new tab)

  11. The effect of chronic low level lead ingestion on blood pressure in young dogs

    … pressures were determined using an indirect Doppler technique.</p><p>Similar blood pressures were recorded for both groups prior to lead dosing. After nine days of lead ingestion, the mean blood pressure of the lead group had risen to 111±9.5 mm Hg (X±SEM), as compared to 88±7.5 mm Hg in …

    njit Repository record for The effect of chronic low level lead ingestion on blood pressure in young dogs (opens in a new tab)

  12. Development of new particles’ concentration and sizing measurement techniques

    … dust measurement in air, and flow analysis techniques such as Laser Doppler Velocimetry (LDV) and Particle Image Velocimetry (PIV). Most existing techniques provide measurements for only one parameter, such as size, concentration, or velocity. Some of the most accurate methods, including the …

    laurentian Repository record for Development of new particles’ concentration and sizing measurement techniques (opens in a new tab)

  13. High frequency coherent doppler sonar for probing surf zone turbulence

    … and applica­tion of a high frequency coherent Doppler sonar for field measurements of turbulence in the surf zone, and presentation of preliminary analysis of the resulting observations including estimation of the dissipation rate of turbulent kinetic energy. The development of the signal …

    uvic Repository record for High frequency coherent doppler sonar for probing surf zone turbulence (opens in a new tab)

  14. A new model to study human microvascular reactivity in vivo

    … reactivity to locally applied drugs (e.g. laser-Doppler technique following drug delivery by iontophoresis) is available. Therefore, the aim of the present study was to develop a new model to directly study human microcirculatory reactivity in vivo, in particular, to the effects of locally …

    fu-berlin Repository record for A new model to study human microvascular reactivity in vivo (opens in a new tab)

  15. DEVELOPMENT OF AN ISAR IMAGING ALGORITHM

    … proposed algorithms and the conventional Range-Doppler technique has also been made. When a target moves along a straight line, the effective rotation is accompanied by undesirable translational motion which must be compensated. Among several motion compensation methods, the scheme of scattering …

    nus Repository record for DEVELOPMENT OF AN ISAR IMAGING ALGORITHM (opens in a new tab) Download file for DEVELOPMENT OF AN ISAR IMAGING ALGORITHM (opens in a new tab)

  16. Sensitive and high-precision rovibrational spectroscopy of molecular ions relevant to astronomical and quantum chemistry

    … ways to improve highly sensitive and selective techniques in ion spectroscopy to precisely and accurately determine rovibrational transition frequencies of a number of astronomically and fundamentally important molecular ions. The sub-Doppler technique Noise Immune Cavity Enhanced Optical …

    uiuc Repository record for Sensitive and high-precision rovibrational spectroscopy of molecular ions relevant to astronomical and quantum chemistry (opens in a new tab)

  17. Coherent Differential Absorption Lidar for Combined Measurement of Wind and Trace Atmospheric Gases

    … the atmosphere. This lidar combines the coherent Doppler technique for wind detection and the differential absorption lidar (DIAL) technique to provide a multifunctional capability. DIAL and coherent lidars have traditionally been thought of and implemented as separate instruments, but the …

    odu Repository record for Coherent Differential Absorption Lidar for Combined Measurement of Wind and Trace Atmospheric Gases (opens in a new tab)

  18. Fluid Dynamic Assessments of Spiral Flow Induced by Vascular Grafts

    … distortion. A dual-beam two-dimensional vector Doppler technique was developed to visualise and quantify vortical structures downstream of each graft outflow in the cross-flow direction. Vorticity mapping and measurements of circulation were acquired based on the vector Doppler data. The flow …

    dundee Repository record for Fluid Dynamic Assessments of Spiral Flow Induced by Vascular Grafts (opens in a new tab) Download PDF for Fluid Dynamic Assessments of Spiral Flow Induced by Vascular Grafts (opens in a new tab)