Quantitative measurements of Rhenium-188 for radionuclide therapies
… are accurate, a practical method to determine dose-calibrator dial settings using a thyroid-probe was developed; 2) to assess the influence of ¹⁸⁸Re multiple emissions on quantitative imaging, a series of Monte-Carlo simulations of ¹⁸⁸Re single photon emission computed tomography (SPECT) were …
-
Development of a Practical Lu-177 Activity Calibration Protocol for Clinical Nuclear Medicine: Dosimetric Impact Analysis and Implementation Tools
… treatment delivery. However, variability in dose calibrator response due to measurement conditions and source geometry remains a practical challenge in routine clinical settings. This study presents a practical clinical calibration strategy under real-world constraints for Lu-177 activity …
-
Quantitative Multiplexed Multi-pinhole Small-Animal SPECT
… as low as 1% in phantoms, relative to dose calibrator measurements. The systematic and random uncertainties for measurements of total cardiac tracer uptake in vivo compared to well chamber measurements ex vivo were as small as –1% and 3% respectively.Reevaluation of the reproducibility …
-
Evaluation of a Dedicated SPECT-CT Mammotomography System for Quantitative Hybrid Breast Imaging
… anatomical imaging obtained with a low dose x-ray Computed Tomography (CT) subsystem. In this new breast imaging paradigm, coined "mammotomography," the subject is imaged lying prone while the individual subsystems sweep 3-dimensionally about her uncompressed, pendant breast, providing …
-
Lu-177 Automated Quantification Capabilities of Siemens Symbia Intevo 16.
… Prior to the phantom study, the accuracy of the dose calibrator and deadtime effects were addressed. Optimal measurement conditions for Lu-177 in a vial and syringe were determined; both are clinically relevant and applied to this study. The Lu-177 manufacturers’ activity was used for comparison …
-
Ein effektiver und verlässlicher Ansatz zur Reduktion der Strahlenexposition des medizinischen Personals im Kontext der Radiojodtherapie
Die Validierung der Aktivität der Jod-131-Kapseln vor der Radiojodtherapie ist gesetzlich vorgeschrieben. Die Anwendung des dargestellten alternativen Messverfahrens führt zu einer erheblichen Reduktion der Strahlenbelastung des medizinischen Personals und insbesondere der Hände. Es ermöglicht eine …