Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 12 of 12 for “"Dose Computation"”
-
Dose computation for therapeutic electron beams
The accuracy of electron dose calculations performed by two commercially available treatment planning computers, Varian Cadplan and Helax TMS, has been assessed. Measured values of absorbed dose delivered by a Varian 2100C linear accelerator, under a wide variety of irradiation conditions, were …
-
The application of parallel processing to radiotherapy dose computation
Delivery of the correct dose to patients undergoing high-energy x-ray radiotherapy treatment for cancer requires accurate simulation of photon beams. Current algorithms using equivalent depth or tissue-air ratio (TAR) correction techniques fail to accurately model electron transport, and hence show …
-
Influence on different Monte-Carlo variances at the dose calculation and the impact to the commissioning
… is gradually being introduced for clinical dose computation in the quest to improve the accuracy of predicting the dose distribution to a medium from a given beam setup. Dosimetric measurement is used to verify the accuracy of the calculated dose distribution before the beam setup can be …
-
Development of a Forward/Adjoint Hybrid Monte Carlo Absorbed Dose Calculational Method for Use in Radiation Therapy
… at conforming (i.e., concentrating) radiation dose to the entire tumor volume (i.e., diseased area) while avoiding surrounding normal tissue (i.e., healthy non-diseased areas). This objective is achieved clinically by finding a set of radiation beam parameters that successfully deliver the …
-
An X-ray Source Model and Characterization Method for Computing kV Radiation Dose
… to assess, reduce, and optimize the imaging dose delivered during image-guided radiation therapy. It is currently difficult to accurately estimate patient-specific spatial dose distributions deposited by kilovoltage (kV) cone-beam CT (CBCT) using existing techniques. This thesis describes the …
-
Optimization of Computed Tomography Calibration Curve for Proton Therapy Treatment Planning
The accuracy of proton dose computation in the treatment planning system relies on the conversion from the Hounsfield units (HU) of each voxel in the patient CT scan to the proton stopping power ratio (SPR). The aim of this study is to investigate the potential improvement in determining proton SPR …
-
Implementation of the Dosimetry Check Software Package in Computing 3D Patient Exit Dose Through Generation of a Deconvolution Kernel to be Used for Patients’ IMRT Treatment Plan QA
… a deconvolution kernel to be used in exit image dose calculations was created. This kernel modeled Electronic Portal Imaging Device response by incorporating the various machine characteristics along with the variant patient thickness and composition. To properly achieve this, Dosimetry Check …
-
Development of Monte Carlo Treatment Planning and Dosimetry System for Small Animal Irradiator
… irradiator. To accomplish this, the absolute dose calibration of the irradiator performed in accordance with the recommendations of AAPM TG-61 protocol. Both in-air and in-water calibrations were performed at a 30.5 cm source-to-surface distance (SSD) for the reference applicator 40x40 mm2 …
-
Forward and Inverse Treatment Planning Solutions for Small Animal Radiation Research
… systems, the need to understand the amount of dose deposited to different tissue types and to visualize the resulting dose distribution have motivated the development of treatment planning systems (TPS). Treatment planning in radiation therapy is often performed with a forward strategy to reuse …
-
On Tumor Motion, Delineation Strategies, and Respiratory Induced Density Variations Associated with Stereotactic Lung Radiotherapy
… radiotherapy exploits the use of an ablative dose which demands the highest levels of precision and accuracy in every aspect of the treatment planning and delivery process. Hence, motion management, implementation of very small tumor margins, and the accuracy of the dose distribution predicted …
-
Méthodes numériques en imagerie médicale pour l'évaluation de dose per-opératoire en ablation par électroporation
Alors que l’espérance de vie augmente, le cancer est devenu l’une des principales causes de décès dans le monde. Parmi les cancers les plus difficiles à traiter figurent les tumeurs profondes, qui sont compliquées à soigner en raison de leur emplacement près de structures vitales dans des organes …