Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 35 for “"Dose Profile"”.

  1. Dose profile surrounding a waste repository

    … wall, allowing for crane maneuverability. The dose rate profile was analyzed using Monte Carlo N-Particle Transport eXtended (MCNPX) for the south, west, and north sides. The east side was not explicitly analyzed, because of the symmetry between the west and east sides. The dose rate was …

    colostate Repository record for Dose profile surrounding a waste repository (opens in a new tab)

  2. Assessment of spatially inhomogeneous intra-organ radiation dose response in salivary glands

    … growth at the site of origin. To achieve doses high enough to attain ‘local control’ and inhibit growth of metastases, surrounding normal tissues are selectively co-irradiated. Current clinical practice for head-and-neck cancers involves salivary gland irradiation. Threshold doses that …

    ubc Repository record for Assessment of spatially inhomogeneous intra-organ radiation dose response in salivary glands (opens in a new tab) Download PDF for Assessment of spatially inhomogeneous intra-organ radiation dose response in salivary glands (opens in a new tab)

  3. Using Artificial Intelligence Methods to Predict Doses From Large Solar Particle Events in Space

    … manner.</p> <p>The parameterization of a time-dose profile from an SPE reveals that a non-linear 3 parameter Wiebull curve fits the data very well. Neural networks excel at predicting non-linear functions and their processing in a time period that is much shorter than traditional algorithms …

    ut-knoxville Repository record for Using Artificial Intelligence Methods to Predict Doses From Large Solar Particle Events in Space (opens in a new tab)

  4. Dosimetric effects of removing the flattening filter in radiotherapy treatment units

    … in the beam line to provide a uniform lateral dose profile at a specified depth in water. However, for some radiotherapy treatments, a uniform lateral dose profile is not necessary, e.g. stereotactic treatments with small fields or treatments with intensity modulated fields. In this work, a …

    lund Repository record for Dosimetric effects of removing the flattening filter in radiotherapy treatment units (opens in a new tab) Download PDF for Dosimetric effects of removing the flattening filter in radiotherapy treatment units (opens in a new tab)

  5. Development of a Large-Dose, High-Resolution Dosimetry Technique for Microbeam Radiation Therapy using Samarium-Doped Glasses and Glass-Ceramics

    … a microbeam, is delivered to a tumour. The dose at each centre of planar beams is extremely large (several hundred grays) while dose level in the valley between the peaks is below several tens of gray. Moreover, the width of each planar beam is typically 20 - 50 µm, and the distance from a …

    sask Repository record for Development of a Large-Dose, High-Resolution Dosimetry Technique for Microbeam Radiation Therapy using Samarium-Doped Glasses and Glass-Ceramics (opens in a new tab)

  6. Discrete ordinates CT organ dose simulator (DOCTORS)

    … CT has raised concerns regarding long term low-dose radiological risks.</p><p>Currently, the dose to patients is computed using Monte Carlo methods and experimental tests. In other areas of radiation transport, deterministic codes have been shown to be much faster than Monte Carlo …

    must-thes Repository record for Discrete ordinates CT organ dose simulator (DOCTORS) (opens in a new tab)

  7. Avaliação do movimento respiratório em radioterapia utilizando simulação Monte Carlo

    … stereotactic radiotherapy, which applies high doses in a few fractions. The Monte Carlo method is today one of the most powerful tools in dose evaluation in radiotherapy. In this work, the Respiratory Gated Radiotherapy technique was evaluated to verify the magnitude of the movement, and the …

    brazil-uerj Repository record for Avaliação do movimento respiratório em radioterapia utilizando simulação Monte Carlo (opens in a new tab)

  8. Development and Implementation of An Anthropomorphic Pediatric Spine Phantom For The Assessment of Craniospinal Irradiation Procedures In Proton Therapy

    … as a cancer treatment modality, as it allows for dose deposition to the target volume while sparing the surrounding healthy tissue. This technique is advantageous for craniospinal pediatric patients, as it reduces the radiation side effects that can occur. The purpose of this study is to design an …

    uthsc Repository record for Development and Implementation of An Anthropomorphic Pediatric Spine Phantom For The Assessment of Craniospinal Irradiation Procedures In Proton Therapy (opens in a new tab)

  9. Evaluation of Efficiency of Various Materials to Shield from Radiation in Space Using the Monte Carlo Transport Code Called FLUKA

    … The efficiency of a shield is evaluated by the dose profile within the shield and the amount of dose absorbed by a target using the Monte Carlo transport code called FLUKA. The output of this code is validated by recreating the experiments from published papers and comparing the results. Once …

    calpoly Repository record for Evaluation of Efficiency of Various Materials to Shield from Radiation in Space Using the Monte Carlo Transport Code Called FLUKA (opens in a new tab)

  10. Out-of-field organ dose reconstruction for pediatric patients undergoing passive scattering proton therapy

    … proton therapy often offers the more favorable dose profile compared to conventional treatments, such as photon therapy, its clinical advantages have not yet been sufficiently demonstrated. In response to this lack of evidence, the National Cancer Institute (NCI) has begun development of the …

    gatech Repository record for Out-of-field organ dose reconstruction for pediatric patients undergoing passive scattering proton therapy (opens in a new tab)

  11. 4D-VMAT dose calculation using treatment-specific respiratory motions

    … between planned and delivered radiation dose distributions. The purpose of this work was to develop and experimentally validate a method to calculate the VMAT dose distribution in 4-dimensions (4D-VMAT dose calculation), accounting for tumour motion using the respiratory motion waveform …

    ubc Repository record for 4D-VMAT dose calculation using treatment-specific respiratory motions (opens in a new tab) Download PDF for 4D-VMAT dose calculation using treatment-specific respiratory motions (opens in a new tab)

  12. Beta dose calculation in human arteries for various brachytherapy seed types

    This dissertation explores beta dose profile of microspheres packed in arteries, various source geometries of 142Pr that can be used for therapeutic purpose, and dose backscatter factors for selected beta sources. A novel treatment method by injecting microspheres into feeding arteries of …

    tamu Repository record for Beta dose calculation in human arteries for various brachytherapy seed types (opens in a new tab)

  13. Assessment of single-spot TOPAS MC simulation for proton pencil beam scanning in homogeneous and heterogeneous media and quantification of dosimetric impact of CT metal artifact on IMPT and VMAT plans

    … thriving worldwide. The accuracy of proton dose calculation that based on proper modeling for each single scanning spot as well as accurate CT image data is crucial. The goal of this work is first to investigate the lateral dose profile (LAT) for analytical proton beam algorithm (PBA) in …

    ecu Repository record for Assessment of single-spot TOPAS MC simulation for proton pencil beam scanning in homogeneous and heterogeneous media and quantification of dosimetric impact of CT metal artifact on IMPT and VMAT plans (opens in a new tab)

  14. Operational radiation safety considerations during superficial x-ray treatment for veterinary applications

    … SRT-100™ result in a significant occupational dose to veterinary personnel present in the room during treatment. Measurements were taken for 50, 70, and 100 kV x-ray for 9 different SRT-100 applicators. The exposure rates at the surface of solid water phantom (SWP) phantom ranged from 3.9 mR/hr …

    colostate Repository record for Operational radiation safety considerations during superficial x-ray treatment for veterinary applications (opens in a new tab)

  15. Incorporation of biological factors in radiation therapy treatment planning

    … contributed to iterative improvements in precise dose delivery. These advances have enabled highly conformal tumouricidal dose deposition with improved healthy tissue sparing. Proton therapy, in particular, has become an increasingly adopted modality due to its favourable depth-dose profile, …

    oxford Repository record for Incorporation of biological factors in radiation therapy treatment planning (opens in a new tab)

  16. Implementation of An Anthropomorphic Phantom For The Evaluation of Proton Therapy Treatment Procedures

    … to confirm agreement between the measured dose and calculated dose within 5%/3mm with a reproducibility of 3%. A pelvis phantom originally designed for use with photon treatments was retrofitted for use in proton therapy. The relative stopping power (SP) of each phantom material was …

    uthsc Repository record for Implementation of An Anthropomorphic Phantom For The Evaluation of Proton Therapy Treatment Procedures (opens in a new tab)

  17. Experimental Verification of 4D Monte Carlo Simulations of Dose Delivery to Moving and Deforming Anatomies

    … this work was to validate a 4D Monte Carlo (MC) dose calculation tool (4DdefDOSXYZnrc/EGSnrc) by comparing dose calculations with measurements in rigid and deforming anatomies. This 4DMC approach, that is based on the voxel warping method, calculates the cumulative dose by including continuous …

    carleton Repository record for Experimental Verification of 4D Monte Carlo Simulations of Dose Delivery to Moving and Deforming Anatomies (opens in a new tab)

  18. A mechanistic understanding of the postantibiotic effect and treatment strategies

    … of total antibiotic, regardless of how the dose profile. Moreover, a minimal model of transport and binding kinetics was sufficient to recapture this trend, suggesting a unifying explanation for historical observations of PAE in a variety of contexts. I validated this modeling using both in …

    duke Repository record for A mechanistic understanding of the postantibiotic effect and treatment strategies (opens in a new tab)

  19. Optical and thermal properties of samarium-doped fluorophosphate and fluoroaluminate glasses for high-dose, high-resolution dosimetry applications

    … X-ray induced defects saturate at the same dose. The optimum doping concentration is in the 0.001˗ 0.2 at.% range. Doping with higher concentrations will decrease the conversion efficiency. The glass plates also show a very promising spatial resolution (as high as a few microns) for …

    sask Repository record for Optical and thermal properties of samarium-doped fluorophosphate and fluoroaluminate glasses for high-dose, high-resolution dosimetry applications (opens in a new tab)

  20. Developing a QA procedure for gated VMAT SABR treatments using 10 MV beam in flattening-filter free mode

    … mode. This method takes advantage of the high dose gradient region of SABR treatments to detect any inaccuracies in the performance of the Varian Real-time Position Manage- ment (RPM) gating system. This study involves the design and construction of an interface that connects the translation …

    uvic Repository record for Developing a QA procedure for gated VMAT SABR treatments using 10 MV beam in flattening-filter free mode (opens in a new tab)

Page 1 of 2