Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 44 for “"Dose Volume Histogram"”.

  1. Moment Constraints in Radiation Therapy Planning Optimization Incorporating Patient-Specific Anatomical Geometry

    … healthy structures. In inverse planning, dose-volume histogram (DVH) is a key concept for measuring and restricting collateral radiation damage to healthy tissues. Interpreting the DVH as a probability distribution, a framework is proposed to assess the deviation from a reference …

    calgary Repository record for Moment Constraints in Radiation Therapy Planning Optimization Incorporating Patient-Specific Anatomical Geometry (opens in a new tab)

  2. Beam angle and fluence map optimization for PARETO multi-objective intensity modulated radiation therapy treatment planning

    … of a conformity-based Planning Target Volume (PTV) objective function and a dose-volume histogram or equivalent uniform dose -based objective function for Organs-At-Risk (OARs) produced relatively uniform and conformal PTV doses, with well-spaced beams. For two patient data sets, the …

    manitoba Repository record for Beam angle and fluence map optimization for PARETO multi-objective intensity modulated radiation therapy treatment planning (opens in a new tab)

  3. Development of A Beam-Specific Planning Target Volume and A Robust Plan Analysis to ol For Proton Therapy

    … growing increasingly popular due to its superior dose characteristics compared to conventional photon therapy. Protons travel a finite range in the patient body and stop, thereby delivering no dose beyond their range. However, because the range of a proton beam is heavily dependent on the tissue …

    uthsc Repository record for Development of A Beam-Specific Planning Target Volume and A Robust Plan Analysis to ol For Proton Therapy (opens in a new tab)

  4. Characterization of Physical and Dosimetric Aspects of SRS HyperArc Treatment Technique

    … technique using stereotactic radiosurgical doses delivered via single isocenter volumetric modulated arcs (VMAT) for multi-lesion brain cancer. Due to the nature of these types of treatments it is imperative that the proper quality assurance is completed to ensure the safety of the patient. …

    unlv Repository record for Characterization of Physical and Dosimetric Aspects of SRS HyperArc Treatment Technique (opens in a new tab)

  5. Low History VMAT Monte Carlo Dose Matrix Denoising with Digital Smoothing Filters

    … verification of VMAT treatment planning system dose calculations. Methods: For a VMAT patient treatment plan created for a TrueBeam linac, DICOM information was exported locally from Eclipse after anonymization. The input files for Monte Carlo simulation were then generated with the user code …

    buffalo Repository record for Low History VMAT Monte Carlo Dose Matrix Denoising with Digital Smoothing Filters (opens in a new tab)

  6. Evaluation of an intraoperative iodine-125 brachytherapy implant technique

    … superimposed on the intra-operatively obtained volume study. Dosimetric evaluation of each implant was based on the dose volume histogram (DVH) generated from CT studies and analysis of image and seed numbers, target volume and inferior extent of posterior planes. These parameters showed that …

    unlv Repository record for Evaluation of an intraoperative iodine-125 brachytherapy implant technique (opens in a new tab)

  7. SpaceOAR hydrogel optimization and management for rectal sparing in prostate cancer patients

    … gland and rectum can significantly reduce the dose received by the rectum and hence risk of rectal toxicity. The optimal way to manage the hydrogel and rectal structures for plan optimization is therefore of interest. A retrospective planning study was completed with 13 patients to examine …

    uvic Repository record for SpaceOAR hydrogel optimization and management for rectal sparing in prostate cancer patients (opens in a new tab)

  8. p-Cone Optimization with Application to Radiotherapy Planning

    … is proposed to enable embedding of so-called dose volume histogram in the context of radiation therapy planning optimization. We investigate the suitability of the newly proposed method and compare its performance to other three known methods to replicate a set of dose volume histograms. We …

    calgary Repository record for p-Cone Optimization with Application to Radiotherapy Planning (opens in a new tab)

  9. Investigation of automatic treatment planning (ATP) optimization using an Adaptative Neuro-Fuzzy AI system

    … generating and optimizing ANFIS rules to enhance dose distribution and treatment plan quality, and (3) evaluating ANFIS performance using clinical prostate and head \& neck cancer cases.</p><p>The proposed system is trained using a dataset of optimized treatment plans, leveraging a plan scorecard …

    duke Repository record for Investigation of automatic treatment planning (ATP) optimization using an Adaptative Neuro-Fuzzy AI system (opens in a new tab)

  10. Assessing the accuracy of artificial intelligence synthetic CT generation for liver and brain MRI-only radiotherapy

    … radiotherapy using synthetic CT (sCT) for dose calculation and patient positioning verification. This thesis aimed to provide clinical evidence for the technical feasibility and clinical implementation of MRI-only radiotherapy for liver and brain cancer. Methods: (i) A PRISMA-guided …

    whiterose Repository record for Assessing the accuracy of artificial intelligence synthetic CT generation for liver and brain MRI-only radiotherapy (opens in a new tab)

  11. Assessment of Collimator Jaw Optimization In Reducing Normal Tissue Irradiation With Intensity Modulated Radiation Therapy

    Purpose: To evaluate normal tissue dose reduction in step-and-shoot intensity-modulated radiation therapy (IMRT) on the Varian 2100 platform by tracking the multileaf collimator (MLC) apertures with the accelerator jaws. Methods: Clinical radiation treatment plans for 10 thoracic, 3 pediatric and 3 …

    uthsc Repository record for Assessment of Collimator Jaw Optimization In Reducing Normal Tissue Irradiation With Intensity Modulated Radiation Therapy (opens in a new tab)

  12. Four-Dimensional In Vivo Dosimetry By Dose Reconstruction Using Continuous Epid Images And Phase Sorting Method

    … dosimetry is widely used for patient specific dose evaluation and treatment verification in external beam radiation therapy (EBRT). There is a growing interest in using an electronic portal imaging device (EPID) for in vivo dosimetry, by correlating pixel values of measured EPID images to …

    ecu Repository record for Four-Dimensional In Vivo Dosimetry By Dose Reconstruction Using Continuous Epid Images And Phase Sorting Method (opens in a new tab)

  13. Optimising Individual Treatment Regimes and Patient Outcomes through the Use of Patient-Reported Toxicity Assessments in Patients treated with Pelvic Radiotherapy

    … at risk (OAR) contouring and methods used for dose-volume-histogram (DVH) export were developed. The cross sectional (n=315) and prospective studies (n=129) found bowel urgency and sexual dysfunction to be the late AE most commonly reported by patients. The cross sectional study piloted the …

    whiterose Repository record for Optimising Individual Treatment Regimes and Patient Outcomes through the Use of Patient-Reported Toxicity Assessments in Patients treated with Pelvic Radiotherapy (opens in a new tab)

  14. Investigation of a Monte Carlo model based dose calculation for Pd-103 low dose rate breast brachytherapy and I-125 low dose rate prostate brachytherapy

    … inhomogeneities. Monte Carlo (MC) model-based dose calculation algorithms (MBDCA) provide improved dosimetric accuracy. The purpose of this work was to quantify the impact of eb_gui, a Canadian developed, user-friendly MC MBDCA, on plan evaluation with 80 low dose rate (LDR) breast …

    ubc Repository record for Investigation of a Monte Carlo model based dose calculation for Pd-103 low dose rate breast brachytherapy and I-125 low dose rate prostate brachytherapy (opens in a new tab)

  15. Assessment of Adaptive Radiotherapy Workflows for Head and Neck Cancer

    … between relative change in EPID measured transit dose and relative change in dose volume histogram (DVH) metrics to target and OAR structures over the course of treatment. The in-house developed script was capable of predicting measured EPIs dose in the setting of pre-treatment quality assurance …

    adelaide Repository record for Assessment of Adaptive Radiotherapy Workflows for Head and Neck Cancer (opens in a new tab)

  16. Improving The Accuracy of Radiation Pneumonitis Dose Response Models

    … been reported to be 15%. Studies have shown that dose escalation to the tumor can lead to better local control and subsequently better overall survival. However, dose to lung tumor is limited by normal tissue toxicity. The most prevalent thoracic toxicity is radiation pneumonitis. In order to …

    uthsc Repository record for Improving The Accuracy of Radiation Pneumonitis Dose Response Models (opens in a new tab)

  17. Evaluation of volumetric modulated arc therapy and quality assurance based on Monte Carlo simulation

    … means of rotational dynamic techniques, such as Volumetric Modulated Arc Therapy (VMAT), can be considered a step forward in comparison to conventional, static technique, providing demanding dose distributions in short irradiation times. However this dynamic implementation involves two main …

    sevilla Repository record for Evaluation of volumetric modulated arc therapy and quality assurance based on Monte Carlo simulation (opens in a new tab)

  18. A probabilistic framework for prostate core-needle biopsies in HDR brachytherapy : from clinical quality assurance to translational research

    … core-needle biopsies acquired during high-dose-rate (HDR) brachytherapy are clinically useful for diagnosis and can also support translational research when linked to sampled tissue, imaging-defined anatomy, and delivered dose. The main obstacle is that the effective biopsy location is …

    ubc Repository record for A probabilistic framework for prostate core-needle biopsies in HDR brachytherapy : from clinical quality assurance to translational research (opens in a new tab)

  19. Magnetic Resonance Only Planning Validation Using Synthetic CT by MVision

    … uncertainty while supporting rapid dose recalculation for fraction-level adaptation. Procedure: Magnetic resonance imaging DICOM data were exported from the ViewRay MRIdian treatment planning system and uploaded to MVision for synthetic computed tomography generation. The synthetic …

    vcu Repository record for Magnetic Resonance Only Planning Validation Using Synthetic CT by MVision (opens in a new tab)

  20. Encapsulated Contrast Agent Markers For Mri-Based Post-Implant Dosimetry

    <p>Low-dose-rate prostate brachytherapy involves the implantation of tiny radioactive seeds into the prostate to treat prostate cancer. The current standard post-implant imaging modality is computed tomography (CT). On CT images, the radioactive seeds can be distinctively localized but delineation …

    uthsc Repository record for Encapsulated Contrast Agent Markers For Mri-Based Post-Implant Dosimetry (opens in a new tab)

Page 1 of 3