Results 1 to 20 of 21 for “"Dose area product"”

  1. Radiation dose optimization in interventional radiology and cardiology using diagnostic reference levels

    … optimize their radiation usage using DRLs. The Dose Area Product (DAP) quantity measured for each patient represents a dosimetry index, the value of which for the purpose of improvement should be optimized against the DRL. In this dissertation, I aim to establish if DRLs in the South African …

    cape-town Repository record for Radiation dose optimization in interventional radiology and cardiology using diagnostic reference levels (opens in a new tab)

  2. The dosimetry of small, megavoltage photon fields: correction factors, dose area products and detector designs

    … 35, 5179-5186] recommending the use of point-dose correction factors. This thesis uses Monte Carlo simulations to demonstrate that the values of these correction factors depend strongly on both detector design and field size, as well as other variables such as detector off-axis position and …

    oxford Repository record for The dosimetry of small, megavoltage photon fields: correction factors, dose area products and detector designs (opens in a new tab)

  3. Μεταβολικοί παράγοντες ως δείκτες υποτροπής αρρυθμίας σε διαβητικούς ασθενείς που υποβάλλονται σε κατάλυση κολπικής μαρμαρυγής

    … normal weight patients. Total procedure time and dose area product were significantly increased in obese patients. The multivariate logistic regression analysis revealed that early AF recurrence and duration of hypertension are independent predictors of late AF recurrence.Conclusion CBA is …

    greece Repository record for Μεταβολικοί παράγοντες ως δείκτες υποτροπής αρρυθμίας σε διαβητικούς ασθενείς που υποβάλλονται σε κατάλυση κολπικής μαρμαρυγής (opens in a new tab)

  4. 3D Reconstruction of Interventional Material from Very Few X-Ray Projections for Interventional Image Guidance

    … use too many X-ray images and therefore too much dose per 3D reconstruction. The goal of this thesis was to reconstruct complex arrangements of interventional material from as few X-ray images as possible. To this end, a previously proposed algorithm for the reconstruction of interventional …

    heid-diss Repository record for 3D Reconstruction of Interventional Material from Very Few X-Ray Projections for Interventional Image Guidance (opens in a new tab)

  5. Experimentelle und klinische Dosimetrie bei der Doppelkontrastuntersuchung des Dünndarms (Enteroklysma nach Sellink/Herlinger)

    … zwischen den intrakorporal gemessenen Organdosen und den DFP-Werten wurden geprüft. Mittels linearer Regression konnten Konversionsfaktoren [mGy/cGycm²] erstellt werden. Weiterhin wurden 137 Patienten mittels Enteroklysma untersucht, die DFP-Werte und die Durchleuchtungszeiten gemessen und …

    fu-berlin Repository record for Experimentelle und klinische Dosimetrie bei der Doppelkontrastuntersuchung des Dünndarms (Enteroklysma nach Sellink/Herlinger) (opens in a new tab)

  6. Dose Optimization in Cardiovascular Interventional Radiology

    The thesis treat the patient dose optimization in Carbon Dioxide Angiography and dose reduction with the using of Clarity Philips in EP procedures. Carbon dioxide angiography is based on the visualization (i.e., the radiographic contrast) of gas bubbles injected in blood vessels. By using an …

    bologna Repository record for Dose Optimization in Cardiovascular Interventional Radiology (opens in a new tab)

  7. VHEE dosimetry in a FLASH: ultrahigh dose rate dosimetry and real-time beam monitoring for very high energy electron FLASH radiotherapy

    … scanning or focusing. VHEE beams at ultrahigh dose rates (UHDR) could be beneficial for treating deep-seated tumours using the FLASH effect, which selectively spares healthy tissues while maintaining effective tumour control. One of the main challenges in making VHEE FLASH treatment clinically …

    oxford Repository record for VHEE dosimetry in a FLASH: ultrahigh dose rate dosimetry and real-time beam monitoring for very high energy electron FLASH radiotherapy (opens in a new tab)

  8. Bestimmung der Effektiven Dosis, des Dosisflächenprodukts und eines Korrelationskoeffizienten bei diversen dentalen digitalen Volumentomographen

    … von 0,09 bis 550,68 μGym² und Effektive Dosen von 17,24 bis 395,95 μSv ermittelt. Die Bestimmung eines Korrelationskoeffizienten konnte mit den akquirierten Daten näherungsweise erfolgen. Die Effektive Dosis (E) kann aus dem gemessenen Dosisflächenprodukt über E = 24,23 x DFP0,37 …

    freiburg-diss Repository record for Bestimmung der Effektiven Dosis, des Dosisflächenprodukts und eines Korrelationskoeffizienten bei diversen dentalen digitalen Volumentomographen (opens in a new tab)

  9. Evaluating and optimising direct digital chest radiography

    … study is to evaluate and optimise the patient doses in chest radiography using direct digital X-ray systems. Such imaging systems were first introduced at Barts Health NHS Trust in 2012. The wide dynamic range of such systems is more tolerant to sub-optimal practice and can affect patient …

    ucl Repository record for Evaluating and optimising direct digital chest radiography (opens in a new tab)

  10. Biological Effects of Radiation Exposure During Endovascular Aortic Aneurysm Repair

    … exposure such as personal dosimeters or dose area product (DAP) do not give a true reflection of the biological effect of radiation exposure. <br/>In contrast, bio-dosimetry directly measures the effects of radiation exposure in biological specimens such as circulating lymphocytes, which …

    kings Repository record for Biological Effects of Radiation Exposure During Endovascular Aortic Aneurysm Repair (opens in a new tab)

  11. Optimising access-site risks and complications in coronary angiography and percutaneous coronary intervention

    … accesses, as well as procedural time and dose-area product. However, there was no difference in the number of first pass successes between the two groups. The rate of venepuncture was markedly higher in the transfemoral approach. Ultrasound guidance did not demonstrate a benefit in …

    uws Repository record for Optimising access-site risks and complications in coronary angiography and percutaneous coronary intervention (opens in a new tab)

  12. Tomosynthesis in pulmonary cystic fibrosis

    … scoring system, and to determine the effective dose from chest tomosynthesis in children. In a prospective study starting in 2008 clinical chest radiography or computed tomography (CT) were supplemented with a tomosynthesis examination of the lungs. Tomosynthesis findings were characterized in …

    lund Repository record for Tomosynthesis in pulmonary cystic fibrosis (opens in a new tab)

  13. Produit dose-surface pour la radiothérapie : application aux protocoles de traitements stéréotaxiques

    … significativement des conditions de référence en dose absorbée dans l’eau en un point, telles que décrites dans les protocoles internationaux. La perte de traçabilité ainsi constatée conduit à une augmentation de l’incertitude sur la dose délivrée au patient. Afin de contourner les difficultés de …

    star-france Repository record for Produit dose-surface pour la radiothérapie : application aux protocoles de traitements stéréotaxiques (opens in a new tab)

  14. Cone Beam Computed Tomography - radiation dose and image quality assessments

    … reconstruction, image resolution and radiation dose. When new technology is introduced one must make sure that diagnostic accuracy is better or at least as good as the one it can be expected to replace. The CBCT brand tested was two versions of Accuitomo (Morita, Japan): 3D Accuitomo with an …

    goteborg Repository record for Cone Beam Computed Tomography - radiation dose and image quality assessments (opens in a new tab)

  15. Radiation Dose Estimation for Pediatric Patients Undergoing Cardiac Catheterization

    … in modern imaging systems with automatic dose rate modulation. </p><p>The overall objective of this dissertation was to develop a comprehensive method of radiation dose estimation for pediatric patients undergoing cardiac catheterization. In this dissertation, the research is divided into …

    duke Repository record for Radiation Dose Estimation for Pediatric Patients Undergoing Cardiac Catheterization (opens in a new tab)

  16. Optimisation in digital radiography: Bridging the gap between image data quality and visual perception of anthropomorphic images

    PurposeDose and image quality optimisation of diagnostic digital radiography is a fine balance between health risk induced by ionizing radiation and the resultant image quality. A major challenge is the assessment of image quality. Firstly, objective assessment of image quality using established …

    salford Repository record for Optimisation in digital radiography: Bridging the gap between image data quality and visual perception of anthropomorphic images (opens in a new tab)

  17. Optimisation in digital radiography: Bridging the gap between image data quality and visual perception of anthropomorphic images

    PurposeDose and image quality optimisation of diagnostic digital radiography is a fine balance between health risk induced by ionizing radiation and the resultant image quality. A major challenge is the assessment of image quality. Firstly, objective assessment of image quality using established …

    salford Repository record for Optimisation in digital radiography: Bridging the gap between image data quality and visual perception of anthropomorphic images (opens in a new tab)