Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 179 for “"Dose calculation"”.
-
Dose Calculation For Electron Therapy
The dose delivered by electron beams has a complex dependence on the shape of the field; any field shaping shields, design of collimator systems, and energy of the beam. This complicated dependence is due to multiple scattering of the electron beam as the beam travels from the accelerator head to …
-
Investigation of Acuros XB radiotherapy dose calculation algorithm
… part of the radiotherapy process is the calculation of radiation dose deposition for individual patients. Accurate dose calculation provides a foundation for accurate dose prescription and reporting in radiation therapy. Several classes of radiation dose calculation algorithms exist. Some …
-
4D-VMAT dose calculation using treatment-specific respiratory motions
… between planned and delivered radiation dose distributions. The purpose of this work was to develop and experimentally validate a method to calculate the VMAT dose distribution in 4-dimensions (4D-VMAT dose calculation), accounting for tumour motion using the respiratory motion waveform …
-
Radiotherapy Dose Calculation Algorithm Sensitivity To High-Density Artifacts
… planning can be adversely affected by inaccurate dose calculations due to the presence of high-density objects. High-density objects, such as surgical clips, produce artifacts in CT images which can result in errors in dose calculation. Manual correction of voxels containing incorrect information …
-
A study of errors for 4D lung dose calculation
To estimate the delivered dose to the patient during intra-fraction or throughout the whole treatment, it is important to determine the contribution of dose accumulated at different patient geometries to the overall dose. Dose mapping utilizes deformable image registration to map doses deposited on …
-
Dose calculation methodology for irradiation treatment of complex-shaped foods
Dose calculation methodology was developed for irradiation treatment of complex-shaped foods. To obtain satisfactory electron beam irradiation of food products, a strict process control is required to ensure that the dose delivered to all parts of the treated product falls within some specified …
-
Dose Calculation and Prediction Methods for Gamma Knife Stereotactic Radiosurgery
… (GK) workflow, specifically the approximation of dose distributions from GK plan parameters and the prediction of dose distributions using DL. These works contribute towards the larger goal of treatment plan prediction and are seen as intermediate steps towards that end. The approximation of dose …
-
Beta dose calculation in human arteries for various brachytherapy seed types
This dissertation explores beta dose profile of microspheres packed in arteries, various source geometries of 142Pr that can be used for therapeutic purpose, and dose backscatter factors for selected beta sources. A novel treatment method by injecting microspheres into feeding arteries of …
-
Methods for dose calculation and beam characterization in external photon beam radiotherapy
… requires fast and accurate methods for the calculation of an absorbed dose distribution in a patient. Modern dose calculation algorithms also require characterization of the radiation beam produced by a medical linear accelerator. In this thesis, a dose calculation method based on the …
-
Patient-specific internal dose calculation techniques for clinical use in targeted radionuclide therapy
… and develop a set of methods for accurate dose calculation that would be practical to implement into routine clinical use. Towards this aim, a graphical user interface (GUI) was developed in order to handle the large body of data associated with internal dose calculations and to perform …
-
Experimental verification of buildup region dose calculation for a commercial treatment planning system
… was to verify experimentally the buildup region dose calculation for Pinnacle3 (version 9.0), a commercial treatment planning system, commissioned and in use at the Saskatoon Cancer Center. To achieve this, buildup dose measurements using Attix parallel-plate ionization chamber and calculations …
-
Electron Monte Carlo Dose Calculation Model Dependency on Optional Applicator Specific 1D Profiles
The accuracy of a calculated dose distribution compared to the actual dose administered to a patient undergoing electron radiation treatment is dependent upon the configured electron dose calculation algorithm in the treatment planning system (TPS). Configuration of the electron Monte Carlo (eMC) …
-
Influence of Lung Tissue Heterogeneity on Dose Calculation in Stereotactic Body Radiation Therapy
… non-small cell lung cancer. It delivers high doses of radiation to the target over a few fractions. This target is an expansion of the tissue-equivalent tumour into low-density tissue. Historically, lung SBRT treatments have been planned with the Analytical Anisotropic Algorithm. Recently, a …
-
Assessment model for annual worker radiation dose calculation for the 400MWth PBMR plant
… safety planning of a nuclear facility, worker dose assessments play an important role. For water-cooled nuclear power plants, these assessments are based on operational experience gained and data collected during the design and operation of existing reactor designs. Most of the research on high …
-
The effects of anatomic resolution, respiratory variations and dose calculation methods on lung dosimetry
… of this thesis was to explore the effects of dose resolution, respiratory variation and dose calculation method on dose accuracy. To achieve this, two models of lung were created. The first model, called TISSUE, approximated the connective alveolar tissues of the lung. The second model, called …
-
Enhancing the speed of radiotherapy Monte Carlo dose calculation with applications in dose verification
Monte Carlo (MC) methods for radiotherapy dose calculation are widely accepted as capable of achieving high accuracy. In particular, MC calculations have been demonstrated to successfully reproduce measured dose distributions in complex situations where alternative dose calculation algorithms …
-
Reduction of Dose Calculation Errors For Patients With Metal Implants Receiving Photon Radiation Therapy
… these metal implants can degrade the accuracy of dose calculations. Dose calculation errors result from limitations of modern dose calculation algorithms in modeling metal/tissue interface effects. Metals also cause streak artifacts in the computed tomography (CT) images that are used for …
Page 1 of 9