Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 31 for “"Dose calculation algorithms"”.

  1. Commissioning And Validation Of Analytical And Monte Carlo Based Dose Calculation Algorithms For Proton Spot Scanning

    Purpose: Accurate dose calculation is one of the most necessary components of radiation therapy. While the commercially available photon dose calculation algorithm offerings have improved considerably in last decade, proton dose calculations are still performed using the analytical dose calculation …

    wayne-thes Repository record for Commissioning And Validation Of Analytical And Monte Carlo Based Dose Calculation Algorithms For Proton Spot Scanning (opens in a new tab)

  2. Verification of Dose Calculation Algorithms in Treatment Planning Systems for External Radiation Therapy: A Monte Carlo Approach

    … concept, the virtual accelerator, for dose calculation algorithms used in treatment planning systems (TPSs) for external beam radiotherapy. The algorithm input data required to implement a treatment unit in the TPS are generated by Monte Carlo simulations as are the beam reference data …

    lund Repository record for Verification of Dose Calculation Algorithms in Treatment Planning Systems for External Radiation Therapy: A Monte Carlo Approach (opens in a new tab) Download PDF for Verification of Dose Calculation Algorithms in Treatment Planning Systems for External Radiation Therapy: A Monte Carlo Approach (opens in a new tab)

  3. Electron transport in photon and election beam modelling / Paul J. Keall.

    Two rigorous dose calculation methods have been devised to address the deficiencies of currently available dose calculation algorithms. The 1st method incorporates Fermi-Eyges mutiple scattering theory, the 2nd method developed is the Super-Monte Carlo method.

    adelaide Repository record for Electron transport in photon and election beam modelling / Paul J. Keall. (opens in a new tab)

  4. Predictive metrics for moist desquamation in treatment planning for breast radiotherapy

    … (CARA) breast support device. The epidermal dose measurements, treatment plans, and skin assessments from these studies were used to develop models to be applied during treatment planning to reduce the occurrence of MD in breast radiotherapy. In the first study of this thesis, in vivo film …

    ubc Repository record for Predictive metrics for moist desquamation in treatment planning for breast radiotherapy (opens in a new tab) Download PDF for Predictive metrics for moist desquamation in treatment planning for breast radiotherapy (opens in a new tab)

  5. Analysis of the physical factors influencing portal imaging exit dosimetry using Monte Carlo modeling

    … exit dosimetry. In this latter concept, a portal dose image obtained during treatment with an EPID is compared with that calculated during treatment planning. The success of this approach will ultimately depend on a proper understanding of the factors that influence the measurement and calculation …

    manitoba Repository record for Analysis of the physical factors influencing portal imaging exit dosimetry using Monte Carlo modeling (opens in a new tab)

  6. Monte Carlo Dose Calculations for Permanent Breast Seed Implant Brachytherapy

    … Monte Carlo code.Considerable discrepancies in dose distributions are demonstrated. Target dose metrics are 4-26\% higher using TG43 assumptions, skin metrics are underestimated by up to 66.5\%, and large disparities are observed in heart, lung, and rib doses. The sensitivity of dose …

    carleton Repository record for Monte Carlo Dose Calculations for Permanent Breast Seed Implant Brachytherapy (opens in a new tab)

  7. Study of wedged asymmetric photon beams

    … have been made in the technology used for dose delivery. However, conventional physical wedges are still in clinical use. The combination of asymmetric field collimation and physical wedge presents a challenge for accurate dose calculation. Algorithms for calculating monitor units (MUs) in …

    ubc Repository record for Study of wedged asymmetric photon beams (opens in a new tab) Download PDF for Study of wedged asymmetric photon beams (opens in a new tab)

  8. A Novel 3D Dose Detector Using A Plastic Scintillator and MV Image Reconstruction

    … linear accelerator (LINAC) to deliver complex dose distributions to a defined target while simultaneously sparing surrounding organs at risk (OARs) and adjacent tissue. Dose calculation algorithms used in treatment planning for these customized distributions generally have high accuracy, but …

    gatech Repository record for A Novel 3D Dose Detector Using A Plastic Scintillator and MV Image Reconstruction (opens in a new tab)

  9. Evaluation of The Effectiveness of Anisotropic Analytical Algorithm In Flattened and Flattening-Filter-Free Beams For High Energy Lung Dose Delivery Using The Radiological Physics Center Lung Phantom

    … Volume (PTV) received 100% of the prescribed dose while ensuring that normal tissue constraints were followed as well. Calculated doses were exported from the Eclipse TPS and compared with the experimental data as measured using thermoluminescence detectors (TLD) and radiochromic films that …

    uthsc Repository record for Evaluation of The Effectiveness of Anisotropic Analytical Algorithm In Flattened and Flattening-Filter-Free Beams For High Energy Lung Dose Delivery Using The Radiological Physics Center Lung Phantom (opens in a new tab)

  10. Investigation of Acuros XB radiotherapy dose calculation algorithm

    … part of the radiotherapy process is the calculation of radiation dose deposition for individual patients. Accurate dose calculation provides a foundation for accurate dose prescription and reporting in radiation therapy. Several classes of radiation dose calculation algorithms exist. Some …

    adelaide Repository record for Investigation of Acuros XB radiotherapy dose calculation algorithm (opens in a new tab)

  11. Benchmarking and Implementation of A New Independent Monte Carlo Dose Calculation Quality Assurance Audit to ol For Clinical Trials

    … treatment planning systems employ a variety of dose calculation algorithms to plan and predict the dose distributions a patient receives during external beam radiation therapy. Traditionally, the Radiological Physics Center has relied on measurements to assure that institutions participating in …

    uthsc Repository record for Benchmarking and Implementation of A New Independent Monte Carlo Dose Calculation Quality Assurance Audit to ol For Clinical Trials (opens in a new tab)

  12. Development of A New Independent Monte Carlo Dose Calculation Quality Assurance Audit to ol For Clinical Trials

    … (TPS) may use a number of different radiation dose calculation algorithms during the planning process. The Radiological Physics Center (RPC), tasked with ensuring clinically comparable and consistent dose delivery amongst institutions participating in NCI funded multi-institutional clinical …

    uthsc Repository record for Development of A New Independent Monte Carlo Dose Calculation Quality Assurance Audit to ol For Clinical Trials (opens in a new tab)

  13. Development of a Forward/Adjoint Hybrid Monte Carlo Absorbed Dose Calculational Method for Use in Radiation Therapy

    … at conforming (i.e., concentrating) radiation dose to the entire tumor volume (i.e., diseased area) while avoiding surrounding normal tissue (i.e., healthy non-diseased areas). This objective is achieved clinically by finding a set of radiation beam parameters that successfully deliver the …

    utk-theses Repository record for Development of a Forward/Adjoint Hybrid Monte Carlo Absorbed Dose Calculational Method for Use in Radiation Therapy (opens in a new tab)

  14. CT Image Electron Density Quantification in Regions with Metal Implants: Implications for Radiotherapy Treatment Planning

    … the expected spatial distribution of absorbed dose in a patient. CT imaging is complicated by the presence of metal implants which cause increased image noise, produce artifacts throughout the image and can exceed the available range of CT number values within the implant, perturbing electron …

    queens Repository record for CT Image Electron Density Quantification in Regions with Metal Implants: Implications for Radiotherapy Treatment Planning (opens in a new tab)

  15. Advancing an Open-Source Radiation Treatment Planning System for Orthovoltage X-ray and Cobalt-60 Teletherapy

    … has evolved from manual planning, where the dose distribution in the target volume was determined using tabulated percent depth dose, to a computerized planning in which dose calculation is performed by dose calculation algorithms on a patient CT data set. Although orthovoltage x-ray beams …

    queens Repository record for Advancing an Open-Source Radiation Treatment Planning System for Orthovoltage X-ray and Cobalt-60 Teletherapy (opens in a new tab)

  16. Application of Machine Learning in Prostate Cancer External Beam Radiation Therapy to Improve Biochemical Failure-Free Survival Prediction

    … BFFS in particular using machine learning (ML) algorithms.Radiotherapy clinical trial protocols are adopted by different institutions due to their promising outcome(s) and/or superior efficiency. In this thesis, we first quantified the plan quality differences across four institutions in Alberta …

    calgary Repository record for Application of Machine Learning in Prostate Cancer External Beam Radiation Therapy to Improve Biochemical Failure-Free Survival Prediction (opens in a new tab)

  17. Advances in Monte Carlo modelling for characterization of specific energy and absorbed dose distributions from cell to patient length scales

    … there is a push to understand radiation dose on a cellular or sub-cellular level. While computing power continues to increase, it is not yet at the point where entire patients can be modelled down to the cellular scale. Therefore, a heterogeneous multiscale MC framework (HetMS-MC) is …

    carleton Repository record for Advances in Monte Carlo modelling for characterization of specific energy and absorbed dose distributions from cell to patient length scales (opens in a new tab)

  18. Methods for dose calculation and beam characterization in external photon beam radiotherapy

    … requires fast and accurate methods for the calculation of an absorbed dose distribution in a patient. Modern dose calculation algorithms also require characterization of the radiation beam produced by a medical linear accelerator. In this thesis, a dose calculation method based on the …

    aalto Repository record for Methods for dose calculation and beam characterization in external photon beam radiotherapy (opens in a new tab)

  19. Enhancing the speed of radiotherapy Monte Carlo dose calculation with applications in dose verification

    Monte Carlo (MC) methods for radiotherapy dose calculation are widely accepted as capable of achieving high accuracy. In particular, MC calculations have been demonstrated to successfully reproduce measured dose distributions in complex situations where alternative dose calculation algorithms …

    uvic Repository record for Enhancing the speed of radiotherapy Monte Carlo dose calculation with applications in dose verification (opens in a new tab)

Page 1 of 2