Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 267 for “"Dose distributions"”.
-
Direct optimization of 3D dose distributions using collimator rotation
… plan without compromising the quality of the dose distribution. It is also shown that an arrangement of equispaced collimator angles takes full advantage of the flexibility associated with collimator rotation. A study including ten recurring nasopharynx cancer patients is used to evaluate the …
-
Improved Calculation and Display for Dose Distributions Associated With Intrauterine Radiotherapy.
A computer program has been developed for dose distribution calculations associated with an intrauterine applicator. The program reconstructs the exact source positions from two orthogonal x-ray projections. The dosages delivered to reference points A and B are calculated. In addition, isodose …
-
Film dosimetry and three-dimensional verification of conformal dose distributions in stereotactic radiosurgery
The measurement of stereotactic radiosurgical dose distributions requires an integrating, high-resolution dosimeter capable of providing a spatial map of absorbed dose. Although radiographic film is an accessible detector fulfilling these criteria, its application to the dosimetry of larger photon …
-
Generation and application of Monte Carlo calculated beamlet dose distributions in radiation therapy
The use of beamlets as a dose calculation tool in Intensity Modulated Radiation Therapy (IMRT) treatment planning is widespread and well documented. A beamlet can simply be defined as the contribution of radiation passing through a particular geometrically defined subdivision of a given linear …
-
Impact of varied low resolution phantoms on intensity modulated proton therapy dose distributions
… techniques in creating accurate proton dose distribution plans. The calculation of the proton dose distribution has to take into account the material (tissue, bone, brain) in the treatment area of the patients body.
-
Impact of varied low resolution phantoms on intensity modulated proton therapy dose distributions
… techniques in creating accurate proton dose distribution plans. The calculation of the proton dose distribution has to take into account the material (tissue, bone, brain) in the treatment area of the patients body.
-
An optical computed tomography scanner for three dimensional gel dosimetry of radiotherapy dose distributions
… specific three dimensional (3D) radiation dose distributions. Treatment planning system (TPS) calculated doses are evaluated by clinicians to ensure suitable dose coverage of targeted tumours and the avoidance of excessive doses to normal tissues. The accuracy of the TPS must be validated …
-
Four-Dimensional MVCT Imaging and Spatial Translation of Helical Tomotherapy Dose Distributions Using Sinogram Modification
… (MLC) control sinogram is used to translate dose distributions in space. A temporal re-binning algorithm was written that divided the MVCT sinogram projections into positional bins that were subsequently used to produce new sinograms for each bin. A CT resolution phantom was placed upon a …
-
Mathematical modelling of tumor control in the context of radiation therapy with deliberate heterogeneous dose distributions
Contents Acknowledgements 3 Preamble 5 1 Background & Motivation 2 Summary & Conclusions Publications I A novel analytical population TCP model includes cell density and volume variations: application to canine brain tumor II A concept for anisotropic PTV margins including rotational setup …
-
Monte Carlo simulation of x-ray dose distributions for direct aperture optimization of intensity modulated treatment fields
… investigates methods of reducing radiation dose calculation errors as applied to a specialized x-ray therapy called intensity modulated radiation therapy (IMRT). There are three major areas of investigation. First, limits of the popular 2D pencil beam kernel (PBK) dose calculation algorithm …
-
Haralick texture analysis for characterization of specific energy and absorbed dose distributions across cellular to patient length scales
… quantitative characterization of dosimetric distributions based on the underlying spatial distribution of data via texture analysis. Monte Carlo simulations are used to generate 3D (micro)dosimetric distributions on cellular and tumour length scales. Haralick features (homogeneity, contrast, …
-
Advances in Monte Carlo modelling for characterization of specific energy and absorbed dose distributions from cell to patient length scales
… there is a push to understand radiation dose on a cellular or sub-cellular level. While computing power continues to increase, it is not yet at the point where entire patients can be modelled down to the cellular scale. Therefore, a heterogeneous multiscale MC framework (HetMS-MC) is …
-
Prediction of proton and neutron absorbed-dose distributions in proton beam radiation therapy using Monte Carlo n-particle transport code (MCNPX)
… model of the human head to predict absorbed dose distributions during proton therapy of ocular tumors. Absorbed dose distributions using the complex geometry were compared to a simple MCNPX model of the human eye developed by Oertli. The proton therapy beam used at Laboratori Nazionali del …
Page 1 of 14