Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 31 for “"Dose gradient"”.
-
Impact of Geometric Uncertainties on Dose Calculations for Intensity Modulated Radiation Therapy of Prostate Cancer
… a radiation field to provide patient-specific dose shaping, resulting in a dose distribution that conforms tightly to the planning target volume (PTV). Unavoidable geometric uncertainty arising from patient repositioning and internal organ motion can lead to lower conformality index (CI), a …
-
Decision-support strategies to improve radiotherapy outcomes in prostate and gynecological cancer treatment planning
… treatment depends on delivering a sufficient dose to the tumour to kill all cancer cells while minimizing radiation exposure to surrounding healthy tissues and nearby sensitive structures known as organs at risk (OARs). Achieving this balance is particularly important in prostate and …
-
Development of a portal dose image prediction algorithm for arbitrary detector systems
… the accurate calculation of a predicted portal dose image, including both primary and scatter dose components emerging from the patient. This thesis presents the development of a two step model that predicts dose deposition in arbitrary portal image detectors. The algorithm requires patient …
-
Δοσιμετρία στη στερεοτακτική ακτινοθεραπεία
… The requirement for high precision and high dose gradient makes stereotactic irradiation a credible method not only in multi fractionated Stereotactic Radiotherapy, but in single-fraction Radiosurgery, as well.The purpose of this thesis was the design and development of a complete …
-
Dual Energy Computed to mography For Proton Therapy Treatment Planning
… because of the unique characteristics of its dose distribution, e.g., high dose-gradient at the distal end of the percentage-depth-dose curve (known as the Bragg peak). The high dose-gradient offers the possibility of delivering high dose to the target while still sparing critical organs …
-
Dynamic photon painting
… the quality of radiosurgery is to increase the dose falloff rate from high dose regions inside the tumor to low dose regions of nearby healthy tissues and structures. Currently, most radiosurgeries rely on focusing a number of external radiation beams to create a sharp dose falloff. As the …
-
Assessment of the potential and risk of fractionated stereotactic radiosurgery for brain lesions using the Gamma Knife system.
… fraction was evaluated by calculating minimum dose, coverage and conformity-index changes for displacements of 0 to 4mm.The impact of positional displacements for 3 and 5 fraction treatments was evaluated for targets and organs-at-risk (OaR) by calculating total doses with simulated …
-
Ανάπτυξη και εφαρμογή ραδιοβιολογικών μοντέλων σε σύγχρονες ακτινοθεραπευτικές τεχνικές
… quantifies the radiobiologicalconsequences of dose gradient effects in brachytherapy applications. The methodology uses the linear-quadratic (LQ) formulation to identify an equivalent Biologically Effective Dose (BEDeq) which, if applied uniformly to a specified tissue volume, would produce the …
-
A Deconvolution Formulation for Cerenkov Light Dosimetry in Radiation Therapy
… radiation therapy as a means to perform in-vivo dose measurement. However, the exact relationship between Cerenkov light emission and dose deposition is not well characterized. In this thesis, the relationship between radiation beam fluence, dose deposition, and Cerenkov light emission is derived …
-
Simulation of the TRIUMF Proton Therapy facility for applications to 3D printing in radiotherapy
… has proven useful in cases where a sharp dose gradient or low secondary irradiation is required. In Canada proton therapy it was performed at the TRIUMF Proton Therapy Facility in the treatment of large or difficultly positioned ocular melanomas. This rare primary malignant cancer of the …
-
A quantitative method for reproducible ionization chamber alignment to a water surface for external beam radiation therapy depth dose measurements
… commonly used detectors for radiation therapy dose measurements. Typical IC measurements use cylindrical ICs in a water phantom and therefore require initial IC alignment to the water surface. This alignment has long been ignored and only recently has a qualitative governing recommendation been …
-
Use of Automatic Metaheuristic Optimizations for Boron Neutron Capture Therapy
… of BNCT is that it can deposit an immense dose gradient between the tumor cells and normal cells. This is done by selectively concentrating boron compounds in tumor cells and then irradiating the cells with an epithermal neutron beam. Due to complex nature of neutron interactions, a high …
-
Validation of Monte Carlo simulation of 6 MV photon beam delivered by the Vero4DRT linear accelerator using BEAMnrc and DOSXYZnrc
… SYNCVMLC component module in BEAMnrc. Radiation doses to patients and phantoms are simulated using DOSXYZnrc codes. Electron energy tuning is achieved by comparing measured vs simulated percentage depth doses (PDDs) for a variety of field sizes in a water phantom. Electron spot size tuning is …
-
Tailoring Camelina Seed Fatty Acid Composition via Fast Neutron Mutagenesis
… Neutron (FN) irradiation applied to seeds in a dose gradient ranging from 7.1 to 49.5 Gy. A range of mutations should be caused following FN irradiation including deletions, point mutations, and rearrangements due to DNA damage and subsequent repair. In germination assays of FN-irradiated seeds, …
-
High Frequency Percussive Ventilation For Tumor Motion Immobilization
… to quantify the interplay effects as well as gradient effects of HFPV vs. free breathing in photon and proton radiotherapy. Furthermore, a retrospective phantom study was performed for quantifying PTV volume reduction as well as doses to the organs at risk. Reproducibility of the HFPV was …
-
A study of errors for 4D lung dose calculation
To estimate the delivered dose to the patient during intra-fraction or throughout the whole treatment, it is important to determine the contribution of dose accumulated at different patient geometries to the overall dose. Dose mapping utilizes deformable image registration to map doses deposited on …
-
Fractional Labelmap Representation of Anatomical Structures
… Errors from conversion affect metrics such as dose volume histograms (DVHs) that are the primary metric for RT plan optimization. The goal of this thesis is to develop fractional labelmaps as a structure representation that preserves more structural information and reduces conversion errors. …
-
Three-Dimensional Transvaginal Ultrasound for Intracavitary and Interstitial Gynecologic High-Dose-Rate Brachytherapy
… intracavitary and interstitial gynecologic high-dose-rate brachytherapy (HDRBT) workflows. The primary limitation of ultrasound imaging is shadowing beyond inserted applicators. To overcome this, ultrasound-compatible vaginal cylinders made of sonolucent material TPX have been previously …
-
Thermoacoustic emission induced by deeply penetrating radiation and its application to biomedical imaging.
… emissions have also been detected from the dose-gradient at the beam edges of a 4 MeV x-ray beam in water. These results establish the feasibility of employing thermoacoustic signals in generating diagnostic images, and in locating x-ray beam edges during radiation therapy. A theoretical …
-
Exploration of the gut-brain axis in adult zebrafish exposed to Perfluorononanoic Acid (PFNA): correlating the intestinal microbiome with neural gene expression.
… of differential transcript abundance across a dose gradient. Additionally, we investigate modulation of the gut-brain axis in adult zebrafish exposed to Perfluorononanoic acid (PFNA) through correlation of intestinal microbiome abundance and neural gene counts. Total RNA from brain and DNA from …
Page 1 of 2