Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 39 for “"Dose measurement"”

  1. 2d dose measurement using a flat panel EPID

    … relies on the use of film for two-dimensional dose distribution verification. Although film is considered the gold standard and is widely used for this purpose, the procedures involved are relatively lengthy, labour intensive and costly for a multiple field IMRT verification. In this study, we …

    ubc Repository record for 2d dose measurement using a flat panel EPID (opens in a new tab)

  2. Radiation dose measurement and prediction for linear slit scanning radiography

    This study describes dose measurements made for linear slit scanning radiography (LSSR) and a dose prediction model that was developed for LSSR. The measurement and calculation methods used for determining entrance dose and effective dose (E) in conventional X-ray imaging systems were verified for …

    cape-town Repository record for Radiation dose measurement and prediction for linear slit scanning radiography (opens in a new tab)

  3. Photodetector calibration for solar SXR and UV dose measurement for correlation with materials degradation on the international space station

    … The detectors will monitor the Solar SXR and UV dose levels over a period of three years while situated in Low Earth Orbit (LEO) on the International Space Station.</p> <p>Calibration of the detectors included measuring their spectral responsivity, spectral transmission of filters, sensitivity to …

    soton Repository record for Photodetector calibration for solar SXR and UV dose measurement for correlation with materials degradation on the international space station (opens in a new tab)

  4. Application of Tissue Equivalent Proportional Counter (TEPC) in Intercalibration with NaI (Tl) Spectrometer

    … as standard instrument for cosmic radiation dose measurement because it can separate gamma and neutron spectra in mixed field microdosimetry. HAWK TEPC was employed in the project as a reference instrument to measure the cosmic radiation exposure in terms of dose equivalent and ambient dose …

    carleton Repository record for Application of Tissue Equivalent Proportional Counter (TEPC) in Intercalibration with NaI (Tl) Spectrometer (opens in a new tab)

  5. Understanding The Influence of Photon Energy On 6Mv Non Reference Dosimetry and Ct Dosimetry Using Tld and Osld

    Measurement of the absorbed dose from ionizing radiation in medical applications is an essential component to providing safe and reproducible patient care. There are a wide variety of tools available for measuring radiation dose; this work focuses on the characterization of two common, solid-state …

    uthsc Repository record for Understanding The Influence of Photon Energy On 6Mv Non Reference Dosimetry and Ct Dosimetry Using Tld and Osld (opens in a new tab)

  6. Optimization of the MgS:Eu:Sm phosphor for potential use as an optically stimulated personnel dosimeter

    … in that they provide a faster, isothermal dose measurement than conventional thermoluminescent dosimeters. The effects of activator concentration and chemical substituents are examined in order to increase OSL intensity, improve the OSL emission wavelength and to increase the chemical …

    vt Repository record for Optimization of the MgS:Eu:Sm phosphor for potential use as an optically stimulated personnel dosimeter (opens in a new tab)

  7. Volumetric Scintillation Dosimetry For Scanned Proton Beams

    … Scanned proton beams can produce complex 3D dose distributions, presenting a challenge for adequate quality assurance testing. Because each scanned beam dose measurement requires the delivery of the entire field, multiple measurements can be time consuming. These quality assurance challenges …

    uthsc Repository record for Volumetric Scintillation Dosimetry For Scanned Proton Beams (opens in a new tab)

  8. Development of fibre optic dosimetry for medical applications

    … emit ionising radiation, which deposits the dose and kills the cancer cells. The dose delivered to the patient is verified from the images taken after treatment. In-vivo dose measurement during the treatment is crucial for better patient outcomes. In this study, we opted for a fibre optic …

    adelaide Repository record for Development of fibre optic dosimetry for medical applications (opens in a new tab)

  9. Commissioning and Implementation of an EPID Based IMRT QA System “Dosimetry Check” for 3D Absolute Dose Measurements and Quantitative Comparisons to MapCheck

    … LLC, provides an absolute 3D volumetric dose measurement for IMRT QA using the existing Electronic Portal Imaging Device (EPID) mounted on most linear accelerators. This package provides a feedback loop using the patient’s treatment planning CT data as the phantom for dose reconstruction. …

    ohiolink Repository record for Commissioning and Implementation of an EPID Based IMRT QA System “Dosimetry Check” for 3D Absolute Dose Measurements and Quantitative Comparisons to MapCheck (opens in a new tab)

  10. Combined methods and instrumentation for dosimetric monitoring of the large fluence hadron irradiations /

    Dosimetry in the routine sense is the measurement of the absorbed dose in biological tissues and matter delivered by ionizing radiation or particle beams. Dosimetry is widely applied in the field of medical physics where it is inevitable for assessment of the radiation dose received by personnel …

    vilnius Repository record for Combined methods and instrumentation for dosimetric monitoring of the large fluence hadron irradiations / (opens in a new tab)

  11. Didelių įtėkių hadronų apšvitų dozimetrijos kombinuoti metodai ir įranga /

    Dosimetry in the routine sense is the measurement of the absorbed dose in biological tissues and matter delivered by ionizing radiation or particle beams. Dosimetry is widely applied in the field of medical physics where it is inevitable for assessment of the radiation dose received by personnel …

    vilnius Repository record for Didelių įtėkių hadronų apšvitų dozimetrijos kombinuoti metodai ir įranga / (opens in a new tab)

  12. Investigating the use of Radiation Sensors for a Novel Device to Benchmark Lethal Doses of Alpha Radiation on Malignant Cells

    … to deliver a highly localised and cytotoxic dose of radiation. However, supply issues, unsuitable testing models and slow development rates have significantly limited the progress made in the clinical translation of research into novel TAT radiopharmaceuticals. This project aims to explore …

    whiterose Repository record for Investigating the use of Radiation Sensors for a Novel Device to Benchmark Lethal Doses of Alpha Radiation on Malignant Cells (opens in a new tab)

  13. A Novel 3D Dose Detector Using A Plastic Scintillator and MV Image Reconstruction

    … linear accelerator (LINAC) to deliver complex dose distributions to a defined target while simultaneously sparing surrounding organs at risk (OARs) and adjacent tissue. Dose calculation algorithms used in treatment planning for these customized distributions generally have high accuracy, but …

    gatech Repository record for A Novel 3D Dose Detector Using A Plastic Scintillator and MV Image Reconstruction (opens in a new tab)

  14. Characterization of a micro-ionization chamber for electron FLASH dosimetry

    … treatment by delivering radiation at ultra-high dose rates (UHDR) exceeding 40 Gy/s. This technique aims to increase normal tissue tolerance while maintaining the anti-tumoral effects of conventional radiotherapy, potentially reducing side effects without compromising treatment efficacy. The …

    ubc Repository record for Characterization of a micro-ionization chamber for electron FLASH dosimetry (opens in a new tab)

  15. Cylindrical Detector and Preamplifier Design for Detecting Neutrons

    … counters are frequently used to measure dose and dose equivalent in mixed radiation fields that include neutrons; however, detectors simulating sites 1?m in diameter underestimate the quality factor, Q, for low energy neutrons because the recoil protons do not cross the detectors. …

    tamu Repository record for Cylindrical Detector and Preamplifier Design for Detecting Neutrons (opens in a new tab)

  16. Ionization Chamber Dosimetry for High Energy Photon and Electron Beams: An Experimental Study

    … the values of CE and Cλ by the ICRU as absorbed dose conversion factors for ionization chambers used in electron or photon beams.</p> <p> This report examines the subject in light of these recent works. Presented is a review of both theoretical and experimental results published to date along …

    mcmaster Repository record for Ionization Chamber Dosimetry for High Energy Photon and Electron Beams: An Experimental Study (opens in a new tab)

  17. A Deconvolution Formulation for Cerenkov Light Dosimetry in Radiation Therapy

    … radiation therapy as a means to perform in-vivo dose measurement. However, the exact relationship between Cerenkov light emission and dose deposition is not well characterized. In this thesis, the relationship between radiation beam fluence, dose deposition, and Cerenkov light emission is derived …

    umn Repository record for A Deconvolution Formulation for Cerenkov Light Dosimetry in Radiation Therapy (opens in a new tab)

  18. Evaluation of Polymer Gel Dosimeters For Measurements of Dose and Let In Proton Beams

    … gel dosimeters as tools for measuring the dose deposited by and LET of a proton beam. A total of three BANG® dosimeter formulations were evaluated: BANG®-3-Pro-2 BANGkits™ for dose measurement and two BANG®-3 variants, the LET-Baseline and LET-Meter dosimeters, for LET measurement. All …

    uthsc Repository record for Evaluation of Polymer Gel Dosimeters For Measurements of Dose and Let In Proton Beams (opens in a new tab)

  19. A MONTE CARLO SIMULATION AND DECONVOLUTION STUDY OF DETECTOR RESPONSE FUNCTION FOR SMALL FIELD MEASUREMENTS

    … The problem is more important in small field measurement, such as stereotactic radiosurgery, small beamlet IMRT, etc. The dosimetry associated with small fields is very difficult because of the steep dose gradients and the lack of lateral electronic equilibrium conditions that complicate the …

    ohiolink Repository record for A MONTE CARLO SIMULATION AND DECONVOLUTION STUDY OF DETECTOR RESPONSE FUNCTION FOR SMALL FIELD MEASUREMENTS (opens in a new tab)

  20. ArcCheck Phantom with Tissue Equivalent Inserts for Validation of Treatment PlanningSystem Dose Calculation in Heterogenous Media

    The convolution-superposition dose calculation algorithm utilized by theRayStation Treatment Planning System (TPS) necessitates that a model of the beam becreated for every linac energy during the TPS commissioning process. This is achievedwith the user measuring depth dose curves and beam profiles …

    ohiolink Repository record for ArcCheck Phantom with Tissue Equivalent Inserts for Validation of Treatment PlanningSystem Dose Calculation in Heterogenous Media (opens in a new tab)

Page 1 of 2