Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 39 for “"Dose prediction"”.
-
Dose Prediction for Radiotherapy of Advanced Stage Lung Cancer
A dose prediction model for treatment planning was generated using U-Net architecture. The model was generated for advanced stage cancer patients. The U- Net architecture was created with depth=6 and kernel=6. The model architecture was successful to reduce the input image size (192X192) to feature …
-
A Method for Online Dose Prediction for Image Guided Proton Therapy
… attempt to design a deterministic algorithm for dose prediction using cone beam CTs (CBCTs) that could output a prediction on the time-scale of pa- tient setup during proton image guided radiotherapy (IGRT). We hypothesized that a com- parative analysis of a reference CBCT (RefCBCT) matching the …
-
Polymer dose prediction for sludge dewatering with a belt filter press
… to belt speed, sludge throughput, and polymer dose. Data indicated that the conditioning and dewatering scheme of the three belt filter presses was a low shear, low total mixing energy operation. The Gt, or total mixing energy, of these operations was in the range of 8,000-12,000. Optimal dose …
-
Accelerated Multi-Criterial Optimization in Radiation Therapy using Voxel-Wise Dose Prediction
… to infer the set of feasible best radiation doses, or the Pareto surface. However, each optimization and calculation can take 10-30 minutes per plan. As a result, generating enough plans to attain an accurate representation of the Pareto surface can be very time-consuming, particularly in …
-
Development of a model-based aluminium dose control for targeted removals of DOM from source waters of wide-ranging qualities used for drinking water supply
… development of models for online and real-time prediction of alum doses for conventional treatment of water at drinking water treatment plants (WTPs). Fluorescence signals (Fl) from a field-deployable probe were utilised for dose prediction. A model-based procedure was developed to account for …
-
Development of a Knowledge-based Planning Pipeline for Gamma Knife Radiosurgery
… manually configure shots to create a desired dose distribution, or inverse planning, where dose distributions are optimized based on multiple clinical objectives. However, both approaches are limited by their reliance on planner experience, in addition to several other drawbacks. To improve …
-
Towards AI-Assisted Personalized Stereotactic Body Radiotherapy – Automated Planning, Radiobiological Modelling and Treatment Modality Selection
… node (PLN) metastases, with deep-learning-based dose prediction developed and evaluated for the lung site only. The framework was developed and validated through seven studies that progressively combined automated plan quality assessment, mechanistic radiobiological modelling, phantom-based …
-
Automated Treatment Planning Framework for Cervical Cancer in Brachytherapy
… and/or interstitial (IS) applicators. In high dose-rate (HDR) BT, a remote afterloader guides the radioactive source to specific dwell positions for defined durations, known as dwell times, allowing for a conformal dose to the tumor while minimizing exposure to surrounding organs at risk (OAR). …
-
Alternating Minimization Algorithms for Dual-Energy X-Ray CT Imaging and Information Optimization
… by applications in radiation oncology, including dose prediction in proton therapy and brachytherapy.In proton therapy dose prediction, the stopping power calculation is based on estimates of the electron density and mean excitation energy. In turn, the estimates of the linear attenuation …
-
A net-risk approach to displacement and reoccupation decision making
… Methodologies for population-level radiation dose prediction have improved, with recent data from contaminated areas in Japan providing real-world information about radiation doses. These improvements have not yet made their way into policies and guidance. The objective of this work is to …
-
Flattening Filter Free photon beams for treatment of early-stage lung cancer: an investigation of peripheral dose
… was to evaluate and compare the peripheral dose associated with VMAT lung SABR treatments for 10X, 6X, and 10X-FFF beams. Flattening Filter Free (FFF) radiotherapy photon beams exhibit high dose rates as compared to standard flattened photon beams. The high dose rates available with FFF …
-
Increasing Inclusion of Participants, Leveraging Gut Microbiomes, and Optimizing Machine Learning Models to Advance Warfarin Precision Medicine
… can be challenging due to large interpatient dose variability and a narrow therapeutic window. Warfarin genotype-guided dose prediction models currently can account for approximately 50% of the total variability seen across patients, however, this number can also be as low as 20% in diverse …
-
Advances in Knowledge-based Planning for Radiotherapy with an Open Framework
… as a two-stage pipeline that first predicts the dose that should be delivered to a patient, and then an optimization model converts that prediction into a treatment plan. Although KBP research is flourishing, it is largely limited to institution-specific datasets and evaluation metrics, which …
-
A Method for Predicting Dose Changes for HN Treatment Using Surface Imaging
… to decreased setup reproducibility and altered dose deposition compared to the original plan. Few clinics have developed a standard method for triggering resimulation and replan due to anatomic changes. This work investigates a new method for determining when to resimulate and replan HNC …
-
CHARACTERIZATION OF BREAST RT TREATMENT BY MULTI-INSTITUTIONAL AI-KNOWLEDGE-BASED PLANNING OPTIMIZATION MODELS
… tool based on artificial intelligence to predict dose distribution to Organs at Risk, particularly the heart, in breast cancer radiotherapy. The goal is to enable physicists to quickly assess, via computed tomography (CT), whether a tangential field plan is adequate or if alternative techniques, …
-
Quantitative evaluation of radiation field behavior in subterranean tunnel environments using Monte Carlo modeling
… decision-making. However, conventional open-air dose-rate assumptions may not adequately represent radiation transport behavior in confined tunnel geometries. This research quantifies gamma radiation transport and effective dose rates in representative subterranean tunnel configurations using …
-
Development of an Independent Monte Carlo Dose Calculation Tool for Validation of the Monaco Electron Treatment Planning System
… systems (TPS) to obtain the most accurate dose predictions. Commercial MC TPSs rely on a number of simplifications to allow doses to be calculated in a clinically relevant timeframe. These simplifications are often out of the user’s control and may have implications on dose calculation …
Page 1 of 2