Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 30 for “"Dose ratio"”.

  1. Portal scatter to primary dose ratio of 4 to 18 MV photon spectra incident on heterogeneous phantoms

    … can also be employed to measure the in vivo dose received by the patient. This thesis investigates the ratio of the dose from patient-scattered particles to the dose from primary (unscattered) photons at the imaging plane, called the scatter to primary dose ratio (SPR). The composition of the …

    ubc Repository record for Portal scatter to primary dose ratio of 4 to 18 MV photon spectra incident on heterogeneous phantoms (opens in a new tab) Download PDF for Portal scatter to primary dose ratio of 4 to 18 MV photon spectra incident on heterogeneous phantoms (opens in a new tab)

  2. Development of an Optimized Delivery Method of Surface Irradiation Using an Electron Beam

    … scattering, to reduce the maximum to minimum dose ratio over the surface of a cantaloupe while also maintaining the electron penetration depth sufficient to provide an adequate dose throughout the rind. This research utilized a set of Monte Carlo N-Particle eXtended (MCNPX) decks to calculate …

    tamu Repository record for Development of an Optimized Delivery Method of Surface Irradiation Using an Electron Beam (opens in a new tab)

  3. Association of genetic and nongenetic variabilities with phenytoin and carbamazepine response phenotypes.

    … (PHT) and carbamazepine (CBZ) namely maintenance dose and drug exposure. These two studies were cross-sectional genetic association studies using a candidate gene approach. Retrospective data were used. The study populations were patients with epilepsy who were unrelated Caucasian Americans or …

    umn Repository record for Association of genetic and nongenetic variabilities with phenytoin and carbamazepine response phenotypes. (opens in a new tab)

  4. Breakpoint Chlorination as an Alternate means for Ammoia-Nitrogen removal at a Water Reclamation Plant

    … to determine the optimum operating pH, Cl₂:NH₃-N dose ratio, S0₂:Cl₂ dose ratio, and the minimum detention time for completion of the breakpoint reaction. Other testing done during Phase I included several special studies; including examination of appropriate analytical methods for monitoring …

    vt Repository record for Breakpoint Chlorination as an Alternate means for Ammoia-Nitrogen removal at a Water Reclamation Plant (opens in a new tab)

  5. Novel approaches to GRID therapy: Electron GRID and photon minibeams

    … radiochromic film) was used to characterize the dose rate and peak-to-valley dose ratio (PVDR) of each of the proposed methods. This presented work shows the calculated and/or measured in-phantom dose distributions from each of these new modalities. In all cases, beam definition similar to or …

    gatech Repository record for Novel approaches to GRID therapy: Electron GRID and photon minibeams (opens in a new tab)

  6. Rotación rápida desde morfina a metadona

    … desde morfina a metadona con una equivalencia o Dose Ratio (DR) 5: 1 y 10: 1, para el control del dolor por cáncer, cuando el primer fármaco no controla el dolor o presenta como efecto secundario neurotoxicidad (NTX). Estudiando: eficacia, seguridad, DR, y factores que determinan esta última. Son …

    ull Repository record for Rotación rápida desde morfina a metadona (opens in a new tab)

  7. Calibration of TLD700: LiF for clinical radiotherapy beam modalities and verification of a high dose rate brachytherapy treatment planning system.

    … emit light proportional to their absorbed dose, in a phenomenon known as thermoluminescence. This phenomenon has applications in dose measurement for radiation research, clinical cancer treatment and personal safety dose monitoring. LiF thermoluminescent dosimeters (TLDs) have a response …

    adelaide Repository record for Calibration of TLD700: LiF for clinical radiotherapy beam modalities and verification of a high dose rate brachytherapy treatment planning system. (opens in a new tab)

  8. Dosimetric Tranferability of a Medical Linear Accelerator Mounted Mini-Beam Collimator

    … of the beam quality (%DD(10)), peak-to-valley dose ratio (PVDR), collimator factor (CF), and relative output factor (OF) were carried out for 2 cm x 2 cm, 3 cm x 3 cm, 4 cm x 4 cm, and 5 cm x 5 cm mini-beam collimated 6 MV fields on each linear accelerator. As well, Monte Carlo simulation of …

    sask Repository record for Dosimetric Tranferability of a Medical Linear Accelerator Mounted Mini-Beam Collimator (opens in a new tab)

  9. Characterization of Oslds For Use In Small Field Photon Beam Dosimetry

    … various correction factors associated with OSLD dose calculations. The uncertainties for each correction factor were also investigated. It was determined that the linearity, depletion, fading, and energy correction factors were identical to the RPC commissioning data for non-masked OSLDs. The …

    uthsc Repository record for Characterization of Oslds For Use In Small Field Photon Beam Dosimetry (opens in a new tab)

  10. Development and Implementation of A Remote Audit to ol For High Dose Rate (Hdr) 192Ir Brachytherapy Using Optically Stimulated Luminescence Dosimetry

    … determine correction factors for linearity with dose, dose rate, and the combined effect of irradiation energy and phantom construction. The uncertainties introduced by source positioning in the phantom and timer resolution limitations were also investigated. It was found that the linearity …

    uthsc Repository record for Development and Implementation of A Remote Audit to ol For High Dose Rate (Hdr) 192Ir Brachytherapy Using Optically Stimulated Luminescence Dosimetry (opens in a new tab)

  11. Determination of Wair value in high energy electron beam

    … and calorimetric measurements with a calculated ratio of the absorbed dose in the detectors. Graphite and aluminum detectors were used and the dose ratio was calculated using the EGSnrc Monte Carlo code. A range of average energies at the measurement point were obtained by inserting absorber …

    carleton Repository record for Determination of Wair value in high energy electron beam (opens in a new tab)

  12. Development of 2-3 mm proton minibeams as a new form of GRID radiotherapy

    … parameters including the peak-to-valley dose ratio (PVDR), dose rate at the Bragg peak and the unwanted neutron dose. Using Monte Carlo code TOPAS we simulated proton pencil-beams that mimic those available at cyclotron-based facilities. We achieved parallel beams of 2-3 mm diameter using …

    gatech Repository record for Development of 2-3 mm proton minibeams as a new form of GRID radiotherapy (opens in a new tab)

  13. Toxicity and Hazard Assessment of Neonicotinoid Insecticides to Aquatic Invertebrates

    … on survival, growth, and emergence at concentrations < 2 μg L-1 for most neonicotinoids. Ceriodaphnia dubia was several orders of magnitude less sensitive compared to insects. Chronic hazard assessment concluded a moderate hazard to aquatic invertebrates for clothianidin, and a high hazard for …

    guelph Repository record for Toxicity and Hazard Assessment of Neonicotinoid Insecticides to Aquatic Invertebrates (opens in a new tab)

  14. Gamma and neutron dose profiles near a Cf-252 brachytherapy source

    A new generation of medical grade Cf-252 sources was developed in 2002 at the Oak Ridge National Laboratory (ORNL). The combination of small size and large activity of these Cf-252 sources makes them suitable to be used with the conventional high-dose-rate (HDR) remote afterloading systems for …

    gatech Repository record for Gamma and neutron dose profiles near a Cf-252 brachytherapy source (opens in a new tab)

  15. Optical characterization of samarium-doped fluorophosphate glass for x-ray dosimetry for microbeam radiation therapy at the Canadian Light Source

    … X-ray transparencies. The peak-to-valley dose ratio (PVDR) is the difference between the dose in the microbeams and the dose delivered between the beams. It is the PVDR that is of biological importance in MRT. Therefore a dosimeter for MRT requires a combination of a large dynamic range …

    sask Repository record for Optical characterization of samarium-doped fluorophosphate glass for x-ray dosimetry for microbeam radiation therapy at the Canadian Light Source (opens in a new tab)

  16. Lutein does not affect the bioefficacy of beta-carotene measured using gas chromatography-combustion interfaced-isotope ratio mass spectrometry (GC-C-IRMS)

    … gas chromatography-combustion interfaced-isotope ratio mass spectrometry (GC-C-IRMS) and highly-enriched 13C-labeled tracers of beta-carotene and lutein, we compared the appearance of 13C-beta-carotene and its cleavage product, 13C-retinol, in plasma after subjects ingested 13C-beta-carotene with …

    iastate Repository record for Lutein does not affect the bioefficacy of beta-carotene measured using gas chromatography-combustion interfaced-isotope ratio mass spectrometry (GC-C-IRMS) (opens in a new tab)

  17. PHARMACOKINETIC AND PHARMACODYNAMIC STUDIES WITH CARDIOVASCULAR DRUGS (PROPANOLOL, ISOPROTERENOL, DIGITOXIGENIN, DIGOXIN).

    … 10, 20, 40, 80, or 160 mg oral propranolol (P) doses q.i.d. The effect of P on resting heart rate (HR) and the HR response to the Valsalva's maneuver, tilt, isoproterenol (ISO), and exercise were measured. The results indicate that the resting HR and the Tachycardiac response to Valsalva and …

    arizona-thes Repository record for PHARMACOKINETIC AND PHARMACODYNAMIC STUDIES WITH CARDIOVASCULAR DRUGS (PROPANOLOL, ISOPROTERENOL, DIGITOXIGENIN, DIGOXIN). (opens in a new tab)

  18. Water-insoluble polymers as binders for controlled release matrix and reservoir pellets

    … of controlled release pellets includes preparation of drug cores using water-soluble binders, followed by coating with release-controlling polymers. The main objective of this work was to investigate the applicability of water-insoluble polymers, usually used for coating, as binders for …

    fu-berlin Repository record for Water-insoluble polymers as binders for controlled release matrix and reservoir pellets (opens in a new tab)

  19. Optimization of β-Lactam/β-Lactamase Inhibitor Dosing

    … the goal of this project was to improve the rational basis for the dosing and pairing of β-lactams and β-lactamase inhibitors that would extend their usefulness against resistant organisms. We used a commercially available and widely used combination (piperacillin/tazobactam) to illustrate …

    houston Repository record for Optimization of β-Lactam/β-Lactamase Inhibitor Dosing (opens in a new tab)

Page 1 of 2