Showing 1 to 20 of 49 for “"Dose verification"”.
-
EPID-based Dose Verification for Adaptive Radiotherapy
Dose verification is a critical component of adaptive radiotherapy, as it provides a measurement of treatment delivery success. Based on the measured outcome, the plan may be adapted to account for differences between the planned dose and the delivered dose. Although placement of an EPID behind the …
-
Absolute Dose Verification in Intensity Modulated Radiation Fields
Made available in DSpace on 2017-07-06T18:42:30Z (GMT). No. of bitstreams: 3 Garada_Masab_H_PhD.pdf: 57446279 bytes, checksum: a6d94fd190db1906d111368f39a7abd5 (MD5) Garada_Masab_H_PhD_ABS.pdf: 696014 bytes, checksum: 6c65f47008bf7b7d7d58407b7e25c4a8 (MD5) license.txt: 4813 bytes, checksum: …
-
Absolute Dose Verification in Intensity Modulated Radiation Fields
… is to device a method for measuring the absolute dose for Intensity modulated radiation fields. An accurate verification and physical measurement of the computed absolute dose in Intensity modulated radiation therapy (IMRT) is a challenging task. There are many sources of errors associated with …
-
Dose verification of a stereotactic IMRT treatment planning system
… and film dosimetry were used to verify dose distributions for a new stereotactic IMRT (Intensity Modulated Radiation Therapy) treatment planning system. This technique combines the principles of stereotactic radiosurgery and IMRT to significantly increase the positioning accuracy …
-
Dose verification of rotating collimator intensity modulated radiation thearpy
… linac. The second is to evaluate whether the dose distributions produced with rotating MLC (RMLC) IMRT are comparable to IMRT plans conventionally delivered, without collimator rotation. First, the Dynamic Beam Delivery (DBD) toolbox, the interface required to independently control collimator …
-
Investigation of Advanced Dose Verification Techniques for External Beam Radiation Treatment
… in radiation therapy to achieve highly conformal dose distributions around the tumour while minimizing dose to surrounding normal tissues. These techniques have increased the need for comprehensive quality assurance tests, to verify that customized patient treatment plans are accurately delivered …
-
Deep Learning-based Onboard Image Guidance and Dose Verification for Radiation Therapy
<p>Onboard image guidance and dose verification play important roles in radiation therapy, which enables precise targeting and accurate dose delivery. However, clinical utilities of these advanced techniques are limited by their degraded image quality due to the under-sampling. Specifically, …
-
Prototype fan beam optical computed tomography scanner for three-dimensional radiotherapy dose verification
… optical attenuation images and dosimetric verification experiments. The principal goal in scanner design and implementation was to satisfy the Radiotherapy Accuracy and Precision (RTAP) criteria consisting of a spatial resolution of 1 x 1 x 1 mm3, an imaging time of 60 minutes, a dose …
-
Enhancing the speed of radiotherapy Monte Carlo dose calculation with applications in dose verification
Monte Carlo (MC) methods for radiotherapy dose calculation are widely accepted as capable of achieving high accuracy. In particular, MC calculations have been demonstrated to successfully reproduce measured dose distributions in complex situations where alternative dose calculation algorithms …
-
Evaluation of Presage® As A 3D Dose Verification to ol In Proton Beams
… techniques have advanced and radiation dose plans have become much more complex over the last decade. This is especially true in proton therapy, which involves extremely steep dose gradients as a result of positioning the Bragg peak to cover the volumes to be treated. The Bragg peak can …
-
Monte Carlo Dose Verification of an X-Ray Beam in a Virtual Water Phantom
… as the most accurate technique for calculating dose distributions in radiation therapy physics. Simulating the particle transport through the treatment head of a linear accelerator utilizing a MC based code is both a widespread and practical approach to determining detailed clinical beam …
-
A Study of IMRT Pre-Treatment Dose Verification Using a-Si Electronic Portal Imaging Devices
… an Electronic Portal Imaging Device (EPID) for dose verification. However, EPIDs have limitations stemming from the non-uniform backscatter due to the support-arm as well as from scatter, glare, and an increased sensitivity to low-energy photons. None of these effects is typically accounted for …
-
Commissioning An Anthropomorphic Spine and Lung Phantom For Remote Dose Verification of Institutions Participating In Rtog 0631
… spinal canal, esophagus, heart, and lungs. The dose to the target volume was measured with axial and sagittal planes of radiochromic film and thermoluminescent dosimeters (TLD). The dose distributions were measured with the radiochromic film calibrated to the absolute dose measured by the TLD. …
-
Study of peripheral dose in stereotactic radiotherapy with cyberknife with the use of the mobileMOSFET dose verification system
The risk of secondary cancer associated with low doses of ionizing radiation, is gaining new interest every day, especially in long term surviving patients. The unavoidable amount of the scattered dose, which is absorbed by radiosensitive tissues/organs away from the irradiated treatment site, …
-
in vivo patient dose verification of volumetric modulated arc therapy including stereotactic body radiation treatment applications using portal dose images
… computing and technical innovation. A system of dose delivery verification has the potential to catch treatment errors and therefore improve patient safety. The goal of this thesis was to create a portal image-based in vivo dose reconstruction model for volumetric modulated arc therapy (VMAT) …
-
Verification of the delivered patient radiation dose for non-coplanar beam therapy
… North America. Its purpose is to deliver a high dose of radiation to the tumor while limiting doses to surrounding normal tissues. This is a challenging task when organs-at-risk (OARs) are in close proximity to the tumor. This is why recently many researchers have investigated the opportunity of …
-
A Portal imager-based patient dosimetry system
A technique for the in vivo dose verification of intensity modulated radiation therapy (IMRT) has been developed. An electronic portal image, calibrated in terms of absolute dose, is acquired for each radiation field following transmission through the patient at the time of treatment. For an IMRT …
-
Cone Beam Optical Computed Tomography-Based Gel Dosimetry
The complex dose distributions delivered by modern, conformal radiation therapy techniques present a considerable challenge in dose verification. Traditional measurement tools are difficult and laborious to use, since complete verification requires that the doses be determined in three dimensions …
Page 1 of 3