Showing 1 to 20 of 274 for “"Dosimeters"”.
-
Accident dosimetry using panasonic dosimeters
… or other extremely high neutron doses need dosimeters, such as thermoluminescent dosimeters, capable of measuring doses associated with these scenarios. In order for a dosimeter to be used in these areas, it must be characterized for accident or high level neutron dosimetry. Panasonic …
-
Tissue-equivalent and nanoparticle doped resin dosimeters
… make, use and analyse these new simplified resin dosimeters.
-
Modeling and Development of Three-Dimensional Gel Dosimeters
… the response of polyacrylamide gel (PAG) dosimeters to a single spherical radioactive brachytherapy seed. Simulations were conducted for a high dose-rate (HDR) seed using 192Ir and a low dose-rate (LDR) seed using 125I. The model is able to predict the amount of polymer formed, the …
-
Gamma heating measurements in LMFBR shields with thermoluminescent dosimeters
<p>An important and relatively new application for the thermolumine-scent dosimeter (TLD) is the direct and simultaneous measurement of gamma-ray energy deposition distributions in heavy metal shields typical to fast breeder reactors. This dissertation describes the development of a TLD dosimetry …
-
Improved recipes for leuco-crystal violet micelle gel dosimeters
… was observed, which suggests that RM LCV gel dosimeters could benefit from a pre-irradiation step to help improve dosimeter sensitivity. Minor dose-rate dependent behavior was observed after multiple gel re-uses; however, no significant behavior was observed at the 95% confidence level. …
-
Improved Recipes for Polymer Gel Dosimeters Containing N-Isopropylacrylamide
… response and ease of manufacture of polymer gel dosimeters that use N-isopropyl acrylamide (NIPAM) as the monomer. An alternative carageenan gelling agent was tested in place of gelatin. Although the carageenan did reduce the gelling time for the dosimeter solution, the dose response of the …
-
Recipe Improvement and Mathematical Modelling of Polymer Gel Dosimeters
A mathematical model for polymer gel dosimeters was extended to simulate the effects of radiation depth doses of various radiation beams on the mass of polymer formed. The influences of monomer diffusion and temperature variation were investigated and predicted by the model. Simulation results …
-
Organic and hybrid polysiloxane-based scintillators and passive dosimeters
The growing interest towards polysiloxane-based radiation detection systems is related with the several advantages that polysiloxanes offer in comparison with other state-of-the-art plastic materials used in scintillation, like polyvinyltoluene and polystyrene. In this respect, polysiloxane …
-
Calibration of thermoluminescent dosimeters for simulated nuclear criticality exposure fields
… system based solely on thermoluminescent dosimeters (TLDs) for calculating neutron doses is rare. Most nuclear accident dosimetry systems include activation foils and pellets for characterizing neutron fields from a criticality event. The following analysis provides the first quantitative …
-
Quality Assurance of Advanced Treatment Modalities Using Presage® Dosimeters
… operating procedure was created. The PRESAGE® dosimeters were extensively tested for dose stability over a range of time for remote dosimetry applications. The effect of temperature changes before, during and after irradiation was investigated. The dosimeter was found to be appropriate for …
-
External detection and measurement of inhaled radionuclides using thermoluminescent dosimeters
Many radiation detection programs use bio-assays, whole-body counters, or air sampling to estimate internal doses. This study examines the possibility of using a common external thermoluminescent dosimeter (TLD) badge as a device for detecting inhaled radionuclides through radiation those …
-
Gamma-ray energy deposition studies using CaF₂:Mn chip thermoluminescence dosimeters
<p>Experimental procedures for calibrating the CaF<sub>2</sub>:Mn chips and the associated readout system using Co-60 and Cs-137 isotopic sources are examined. The resulting procedure for exposure and readout of the CaF<sub>2</sub>:Mn chips is utilized to measure gamma-ray energy deposition …
-
Development of Bayesian procedures for the calibration of film badge dosimeters
<p>Calibration of film badges uses data (z) from a “calibration" experiment. These data consist of pairs z<sub>i</sub>={x<sub>i</sub>,y<sub>i</sub>} where x<sub>i</sub> are exposures fixed and chosen before the experiment and <sub>i</sub> are the corresponding film densities. To describe the …
-
Dose Analysis by Radiation Treatment Planning System (TPS) Software Vs. Thermoluminescent Dosimeters Output
… the dose response recorded by thermoluminescent dosimeters (TLD' s) that were initially introduced in an Anthropomorphic Radiation Therapy (ART) phantom. Before inclusion into the ART Phantom, forty-two TLD's were properly calibrated using an NIST Co-60 source. The calibration of the TLD's took …
-
Development of Mailed Dosimetric Audit for External Beam Radiation Therapy Using Alanine Dosimeters
… centres. The service will use mailed alanine dosimeters, and therefore the main focus of the project was to develop a low dose, clinically applicable, alanine dosimetry protocol. Alanine dosimetry was originally developed for industrial uses of radiation (kGy dose levels) and there are a …
Page 1 of 14