Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 49 for “"Doubly fed induction generators"”

  1. Bit-Stream Control of Doubly Fed Induction Generators

    … technology, especially wind generation. The Doubly Fed Induction Generator (DFIG) is commonly used for wind generation applications as it allows for efficient operation of the wind turbine by varying the speed of the generator without resorting to the use of large power converters. A typical …

    auckland-ms Repository record for Bit-Stream Control of Doubly Fed Induction Generators (opens in a new tab)

  2. The Stability Analysis for Wind Turbines with Doubly Fed Induction Generators

    … the proportional-integral (PI) controllers of a doubly fed induction generator (DFIG) driven by a wind turbine to increase the transient performance based on small signal stability analysis. Firstly, the impact of wind generation is introduced. The stability of power systems with wind generation …

    nebraska Repository record for The Stability Analysis for Wind Turbines with Doubly Fed Induction Generators (opens in a new tab)

  3. Optimal control of wind energy conversion systems with doubly-fed induction generators

    … the fossil energy resource. The WECS using a doubly-fed induction generator (DFIG) to convert mechanical power into electrical power has a significant advantage. This WECS requires a smaller power converter in comparison with a squirrel cage induction generator. Efficiency of the DFIG-WECS can …

    birmingham Repository record for Optimal control of wind energy conversion systems with doubly-fed induction generators (opens in a new tab)

  4. Diagnosis and Isolation of Air Gap Eccentricities in Closed-loop Controlled Doubly-Fed Induction Generators

    With the widespread use of doubly-fed induction generators (DFIG) in wind energy conversion systems, condition monitoring is being given importance. Non-intrusive techniques like motor current signature analysis (MCSA), which involves looking for specific frequency components in the current …

    tamu Repository record for Diagnosis and Isolation of Air Gap Eccentricities in Closed-loop Controlled Doubly-Fed Induction Generators (opens in a new tab)

  5. Utilizing reactive capability of doubly fed induction generators to enhance system voltage performance and withstand wind variability

    … technologies. Within the realm of wind generators, the Doubly Fed Induction Generator (DFIG) is the preferred choice of installation worldwide.</p> <p>Large scale penetration of wind energy in the system raises significant concerns regarding the reliability implications of the inherent …

    iastate Repository record for Utilizing reactive capability of doubly fed induction generators to enhance system voltage performance and withstand wind variability (opens in a new tab)

  6. Fault Diagnosis in AC Drives and Wind Turbine Doubly-Fed Induction Generators Based on Three-Level NPC Converters

    … wind energy conversion systems based on doubly-fed induction generators (DFIGs) are the most popular configuration in the wind energy market due to their advantages such as reduced converter cost, variable speed operation and control capability. On the other hand, multilevel converters …

    coimbro Repository record for Fault Diagnosis in AC Drives and Wind Turbine Doubly-Fed Induction Generators Based on Three-Level NPC Converters (opens in a new tab)

  7. Modeling of doubly-fed induction generators connected to distribution system based on eMEGASim® real-time digital simulator

    … stable test bed for a wind farm composed of six doubly-fed induction generators (DFIGs) connected to a distribution system based on the OPAL-RT’s eMEGASim® real-time digital simulator. The system in this research consists of a 9 MW wind farm, an average SimpowerSystems® DFIG wind turbine, …

    utc Repository record for Modeling of doubly-fed induction generators connected to distribution system based on eMEGASim® real-time digital simulator (opens in a new tab)

  8. Stator inter-turn fault detection of doubly-fed induction generators using rotor current and search coil voltage signature analysis

    … and it is expected to remain so for some time. Doubly Fed Induction Generators (DFIGs) hold more than 50% market share of wind power generators due to its unique benefits of low cost, control capability and scalability. Recent trend of DFIGs installed in wind power are within power range of …

    uvic Repository record for Stator inter-turn fault detection of doubly-fed induction generators using rotor current and search coil voltage signature analysis (opens in a new tab)

  9. Development of Simplified Models of Doubly-Fed Induction Generators (DFIG). A contribution towards standardizedmodels for voltage and transient stability analysis

    With the increasing amounts of wind power being installed on electrical grids, the characterization of wind turbines during all operating conditions is essential for systemoperators to ensure security and stability for their customers. This characterization must be achieved by appropriate models of …

    chalmers Repository record for Development of Simplified Models of Doubly-Fed Induction Generators (DFIG). A contribution towards standardizedmodels for voltage and transient stability analysis (opens in a new tab)

  10. Development of Simplified Models of Doubly-Fed Induction Generators (DFIG) A contribution towards standardizedmodels for voltage and transient stability analysis

    With the increasing amounts of wind power being installed on electrical grids, the characterization of wind turbines during all operating conditions is essential for systemoperators to ensure security and stability for their customers. This characterization must be achieved by appropriate models of …

    chalmers Repository record for Development of Simplified Models of Doubly-Fed Induction Generators (DFIG) A contribution towards standardizedmodels for voltage and transient stability analysis (opens in a new tab)

  11. Development of a System for Testing Grid-connected Doubly Fed Induction Generators with Implementation of a Three-level Neutral-Point-clamped Converter

    … wind turbine power generation technologies, the doubly fed induction generator (DFIG) has been distinctively popular for its lower capital costs especially in higher power applications. In order to study the integration of this type of generator into the grid, a laboratory based DFIG test rig was …

    cape-town Repository record for Development of a System for Testing Grid-connected Doubly Fed Induction Generators with Implementation of a Three-level Neutral-Point-clamped Converter (opens in a new tab)

  12. Development of a DFIG wind energy system for grid integration studies

    Doubly Fed Induction Generators (DFIGs) are common for use in wind power generation. This can be attributed to factors such as the variable speed operation of the rotor, which can be adjusted through control systems with varying wind speed, ensuring more efficient power conversion.The stator …

    cape-town Repository record for Development of a DFIG wind energy system for grid integration studies (opens in a new tab)

  13. Advances to the restoration and stability of converter-dominant power grids

    … (GFM) strategy for wind turbines with doubly-fed induction generators (DFIGs) to withstand restoration transients. Further, electromagnetic transient simulation is employed to study the restoration of wind-dominant grids. Finally, a grid-forming stabilizer is developed to enable …

    iastate Repository record for Advances to the restoration and stability of converter-dominant power grids (opens in a new tab)

  14. Adaptive control and parameter identification of a doubly-fed induction generator for wind power

    The use of Doubly-Fed Induction Generators (DFIG) for wind energy conversion is addressed in this thesis. It is well known that when the stator is connected to the electric grid, the rotor voltage can control both mechanical torque and reactive electric power. To guarantee efficient wind energy …

    nps Repository record for Adaptive control and parameter identification of a doubly-fed induction generator for wind power (opens in a new tab)

  15. Wind energy and power system interconnection, control, and operation for high penetration of wind power

    … capability of wind turbines equipped with doubly fed induction generators. Stator-voltage transient compensation terms are introduced to suppress rotor-current overshoots and torque ripples during grid faults. A dynamic stochastic optimal power flow control scheme is proposed to optimally …

    gatech Repository record for Wind energy and power system interconnection, control, and operation for high penetration of wind power (opens in a new tab)

  16. Enhancing reliability in passive anti-islanding protection schemes for distribution systems with distributed generation

    … radial distribution system with six-1.67 MW Doubly-Fed Induction Generators (DFIG-DGs) wind turbines. Various scenarios of DFIG-DG operating conditions with different types of disturbances for critical breakers are simulated. Conventional passive anti-islanding relays incorrectly detected …

    uwo Repository record for Enhancing reliability in passive anti-islanding protection schemes for distribution systems with distributed generation (opens in a new tab)

  17. Capability of DFIGs to Provide Reactive Power Support and Low Voltage Ride Through in Hybrid Wind Farms with FSIGs

    … farms containing both economical Fixed Speed Induction Generators (FSIGs) and the increasingly popular but more costly Doubly-Fed Induction Generators (DFIGs). Of particular interest is the ability of DFIGs, through manipulation of the converter control, to supply reactive power support to the …

    washington Repository record for Capability of DFIGs to Provide Reactive Power Support and Low Voltage Ride Through in Hybrid Wind Farms with FSIGs (opens in a new tab)

  18. Fault Analysis and Protection of Doubly Fed Induction Generator-Based Wind Farms

    … the fault current behavior of a wind farm with Doubly Fed Induction Generators (DFIG), and identify the electrical protection requirements for a large wind farm. Brief description of wind energy conversion systems including types of wind turbine generators are given in the beginning of the …

    okstate Repository record for Fault Analysis and Protection of Doubly Fed Induction Generator-Based Wind Farms (opens in a new tab)

  19. Hybrid excited synchronous generator design and comparison of direct drive wind turbines

    Various types of electrical generators are used in wind turbines and there is not an agreement on the best generator type. Although, high speed Doubly Fed Induction Generators (DFIGs) are still the most common generator topology utilized in wind turbine systems, there is a trends toward …

    metu Repository record for Hybrid excited synchronous generator design and comparison of direct drive wind turbines (opens in a new tab)

Page 1 of 3