Showing 1 to 8 of 8 for “"Dowel Connections"”.
-
Novel SMA Dowel Connections for Seismically Resilient Timber Buildings
… seismic force resisting systems (SFRSs) rely on connections to dissipate energy; these connections effectively act as a ductile energy-dissipative fuse in extreme loading events. Ductile timber connections traditionally fail from a combination of yielding of fasteners and the crushing of wood …
-
2-D non-linear seismic analysis of one-storey eccentric precast concrete buildings
… under earthquake loading have shown that the connections are likely to be the weakest link in a pre-cast structure, and the stability of the structure under earthquake loading depends upon the strength & stability of these connections. A 2-dimensional non-linear dynamic analysis of a one …
-
Behaviour of Timber-Steel Connections With Slotted-In Plates and Steel Dowels Reinforced With Self-Tapping Screws
… on the performance of single and double-dowel connections with one or two steel slotted-in plates. These small-scale dowelled connections were tested with and without reinforcing screws under parallel-to-grain monotonic and cyclic loads. Screws changed the failure mode of the connection, …
-
The seismic response of a timber frame with dowel type connections
… of timber structures with moment resisting connections. The response of ductile dowel connectors and their effect on the seismic behaviour of semi-rigid timber frames were exarnined. Experimental results from component and frame tests were compared with analytical predictions from two …
-
Perpendicular to grain fracture analysis of wooden structural elements - Models and applications
… application to analysis of beams with a hole and dowel-type connections loaded perpendicular to grain. The experimental tests of glulam beams with a hole include investigations of influence of beam size, bending moment to shear force ratio and hole placement with respect to beam height. A strong …
-
Half-Lap Cross Laminated Timber Pegged Joints
… (Liriodendron tulipifera) CLT diaphragm connections. In addition to the use of Austrian spruce and yellow-poplar CLT, both 1 inch and 1.25 inch diameter pegs were tested in the half-lap connections. The influence of both the CLT species and peg diameter were evaluated for their impact on …
-
Nosná konstrukce haly
Bakalářská práce řeší návrh a posouzení nosné konstrukce víceúčelové haly. Objekt je navržen jako jednopodlažní, osmiúhelníkového půdorysu, s pultovou střechou. Konstrukce haly je tvořena soustavou rámů. Nosná konstrukce je navržena ve dvou variantách - trojkloubové rámy se zakřivenými rohy a nebo …