Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 48 for “"Dqe"”

  1. TOWARD A MORE CLARIFIED DETECTIVE QUANTUM EFFICIENCY METHODOLOGY: STUDY OF THE DQE THEORY AND APPLICATIONS

    Detective quantum efficiency (DQE) is widely accepted as the golden rule to objectively evaluate the performance of x-ray imaging systems. It provides a comprehensive characterization of an x-ray imaging system, because it combines several important image-quality-related measurements such as …

    oklahoma-thes Repository record for TOWARD A MORE CLARIFIED DETECTIVE QUANTUM EFFICIENCY METHODOLOGY: STUDY OF THE DQE THEORY AND APPLICATIONS (opens in a new tab)

  2. Modeling of the frequency dependent detective quantum efficiency of X-ray imaging detectors

    … f , dependent detective quantum efficiency, DQE(f ). In this thesis, we have proposed a parallel cascaded linear system model for calculating DQE(f ) by considering the effects of K-fluorescence reabsorption, the range of primary photo electrons, charge carrier trapping, aperture function, …

    concordia

  3. Comparative Performance Evaluation of Conventional and Folded Detector Structures for X-ray imaging

    … need high detective quantum efficiency (DQE) for getting clear X-ray image. The photoconductor layer thickness plays a very important role in conventional detector structure (i.e., a photoconductor layer is sandwiched between two electrodes where charges are collected in corresponding …

    concordia

  4. INFORMATION TRANSFER EFFICIENCY OF X-RAY IMAGE INTENSIFIER-BASED IMAGING SYSTEMS.

    … measure: the detective quantum efficiency {DQE(f)}, which is a function of the statistically independent frequency channels. The DQE(f) is a combined descriptor which takes into account the signal transfer as well as noise transfer properties of a complete system. For a complicated …

    arizona-thes Repository record for INFORMATION TRANSFER EFFICIENCY OF X-RAY IMAGE INTENSIFIER-BASED IMAGING SYSTEMS. (opens in a new tab)

  5. System characterisation of a full body slit scanning radiography machine : theory and experiment

    … the detector was developed and the theoretical DQE, MTF and NPS were compared to measure values of the RQA7 beam quality described in IEC 6222-1. The effect on Detector DQE of various system parameters such as coupling efficiency, CCD noise and pixel binning was quantified. Also detector …

    cape-town Repository record for System characterisation of a full body slit scanning radiography machine : theory and experiment (opens in a new tab)

  6. Αρχές λειτουργίας λαπαροσκοπικής απεικόνισης

    … την ανιχνευτική κβαντική αποδοτικότητα (DQE) της λαπαροσκοπικής απεικόνισης. Η μεταβολή του DQE θα μελετηθεί για διάφορες παραμέτρους των επιμέρους τμημάτων. Αρχικά θα περιγραφεί το θεωρητικό μοντέλο του γραμμικού συστήματος αξιολόγησης. Η υλοποίηση των αλγορίθμων υπολογισμού των …

    athens Repository record for Αρχές λειτουργίας λαπαροσκοπικής απεικόνισης (opens in a new tab)

  7. Modeling of x-ray photoconductors for x-ray image detectors

    … function (MTF), detective quantum efficiency (DQE), and ghosting of x-ray image detectors have been developed. The modeling works are based on the physics of the individual phenomena and the systematic solution of the fundamental physical equations in the photoconductor layer: (1) semiconductor …

    sask Repository record for Modeling of x-ray photoconductors for x-ray image detectors (opens in a new tab)

  8. An investigation of the imaging performance of CCD based x-ray detectors for digital mammography

    … frequency dependent detective quantum efficiency DQE(f) to characterise the detectors in terms of signal to noise ratio transfer is described. It is shown that direct interactions of x-rays in the CCD act to reduce DQE(f) at high spatial frequencies and severely impair the detectors ability to …

    ucl Repository record for An investigation of the imaging performance of CCD based x-ray detectors for digital mammography (opens in a new tab)

  9. Detection of Signal Parameters and Backscattering Polarimetric Imaging Signatures using Molecular Optical Contrast Agents and Preclinical Liquid Phantoms

    … ratio and detective quantum efficiency (DQE) were calculated. The outcome of this study indicated an increase of the backscattered detected signal, signal-to-noise ratio, and the DQE of the imaging system, with increase in the concentration of optically active contrast agents. The results …

    ohiolink Repository record for Detection of Signal Parameters and Backscattering Polarimetric Imaging Signatures using Molecular Optical Contrast Agents and Preclinical Liquid Phantoms (opens in a new tab)

  10. Modeling and Performance Evaluation of Avalanche Detector Structures for Low Dose Medical X-ray Imaging

    … dependent detective quantum efficiency (DQE). The depth dependent MTF and noise power spectrum (NPS) are modeled by incorporating the Lubberts effect. The theoretical model also considers MTF due to K-fluorescence reabsorption. The model is then compared with experimentally determined …

    concordia

  11. An investigation into the use of charge-coupled devices for digital mammography

    … dependent detective quantum efficiency (DQE(f)). Direct interactions of x-rays with the CCD are shown to give a significant increase in the high frequency values of the MTF. These interactions also act as a source of noise and act to significantly reduce the DQE(f) at all frequencies. A …

    ucl Repository record for An investigation into the use of charge-coupled devices for digital mammography (opens in a new tab)

  12. Quantitative contrast enhanced mammography and evaluation of scientific CMOS active pixels sensors for medical imaging

    … (NPS) and the detective quantum efficiency (DQE). The resulting X-ray imagers offer high sensitivity, low noise, and comparable resolution (MTF=0.1 at 9.5 cycles/mm) with respect to other digital mammographic units. The combined outcome of the above performance resulted in a quantum limited …

    ucl Repository record for Quantitative contrast enhanced mammography and evaluation of scientific CMOS active pixels sensors for medical imaging (opens in a new tab)

  13. Characterization and evaluation of a photostimulable phosphor x ray imaging system.

    … (NPS), and the detective quantum efficiency (DQE). The system rms noise is photon-limited for exposures less than 1.0 mR, but has contributions from phosphor structure and quantization noise for exposures higher than 1.0 mR. The phosphor's information factor is shown to explain deviations from …

    arizona-thes Repository record for Characterization and evaluation of a photostimulable phosphor x ray imaging system. (opens in a new tab)

  14. Assessments of and Applications for High Spatio-Temporal Resolution X-Ray Detectors for Use in Medical Imaging

    … The ROD metric is the product of a detector DQE and a simulated object function, integrated over all spatial frequencies, and divided by the respective integral of another detector. This metric gives an idealized comparison of the performance of two imaging systems in detecting specific …

    buffalo Repository record for Assessments of and Applications for High Spatio-Temporal Resolution X-Ray Detectors for Use in Medical Imaging (opens in a new tab)

  15. A quantitative image evaluation study of a concurrent photon amplification treated emulsion

    … study evaluated detective quantum efficiency (DQE), modulation transfer function (MTF), and information content (IC) as a function of exposure in a comparison between normal exposure and CPA. The results showed CPA to enhance image quality relative to normal exposure at very low exposure …

    rit Repository record for A quantitative image evaluation study of a concurrent photon amplification treated emulsion (opens in a new tab)

  16. Development of a prototype CMOS digital imaging system for X-ray medical applications

    … (NPS) and the detective quantum efficiency (DQE) were estimated. Moreover, the proposed detector was compared under the same conditions to others reported previously, including a detector of wide commercial circulation. The novel detector exhibited comparable or even better performance in the …

    greece Repository record for Development of a prototype CMOS digital imaging system for X-ray medical applications (opens in a new tab)

  17. Characterisation of a Novel Radiation Detector and Demonstration of a Novel Error Detection Algorithm for Application in Radiotherapy

    … to obtain the detective quantum efficiency (DQE) values representing image quality. DQE (0.5) values were 0.46-0.59 for three beam energies. Lassena (MV) was evaluated regarding its dosimetric properties, including linearity based on dose rate, reproducibility, and uniformity. Lassena (MV) …

    ucl Repository record for Characterisation of a Novel Radiation Detector and Demonstration of a Novel Error Detection Algorithm for Application in Radiotherapy (opens in a new tab)

  18. Optimization of Imaging Performance and Conspicuity in Dual-Energy X-ray Radiography

    … function (MTF), detective quantum efficiency (DQE), and noise-equivalent quanta (NEQ) - were computed using cascaded systems analysis extended to DE imaging and combined with a quantitative model of imaging task to yield estimates of detectability across a broad range of DE image acquisition …

    toronto-retro Repository record for Optimization of Imaging Performance and Conspicuity in Dual-Energy X-ray Radiography (opens in a new tab)

  19. Simulation of image formation in nuclear medicine imaging systems using Monte Carlo methods

    … in terms of the Detective Quantum Efficiency (DQE) by estimating the MTF and the Normalized Noise Power Spectrum (NNPS) of the 18F-FDG TLC plane source (1 MBq). MTFs curves were estimated from transverse reconstructed images of the plane source, whereas the NNPS data were estimated from the …

    greece Repository record for Simulation of image formation in nuclear medicine imaging systems using Monte Carlo methods (opens in a new tab)

  20. Προσομοίωση σχηματισμού εικόνας συστημάτων πυρηνικής ιατρικής με μεθόδους Monte Carlo

    … της Ανιχνευτικής Κβαντικής Αποδοτικότητας (DQE) για την εκτίμηση της συνολικής απόδοσης του συστήματος PET, μέσω υπολογισμού της Συνάρτησης Μεταφοράς Διαμόρφωσης και του Κανονικοποιημένου Φάσματος Ισχύος Θορύβου (NNPS). Οι καμπύλες της MTF υπολογίστηκαν από την ανακατασκευή των εγκάρσιων …

    patras-thes Repository record for Προσομοίωση σχηματισμού εικόνας συστημάτων πυρηνικής ιατρικής με μεθόδους Monte Carlo (opens in a new tab)

Page 1 of 3