Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 28 for “"Drift Chamber"”.
-
A helium high temperature drift chamber
… 0.59 ± 0.09 ± 0.10 using a Princeton ionization chamber as the triton detector. The design, construction and development of the TPC is the main emphasis of this thesis. An extensive study of the TPC performance as a function of the electric field at various temperatures and different …
-
Cluster counting studies in a SuperB drift chamber prototype
… physics. The detector at SuperB will contain a drift chamber, a gas filled device used to measure the momentum and identity of particles produced in the collisions. Particle identification in a drift chamber uses the measured amount of ionization deposited by the particle in the cells of the …
-
Charge division in a cylindrical drift chamber for E1097
… review of the key concepts in the operation of a drift chamber are given. The equations governing charge division are developed. In order to optimize the chamber geometry, calculations were performed so that a suitable geometry for the chamber could be chosen. Electronics to determine position …
-
Studies of helium-based gas mixtures using a small cell drift chamber
… proposed to build the central tracking chamber for the BABAR detector. Presently, a prototype drift chamberis in operation and studies are being performed to test some of the unique features of drift chamber design dictated by the conditions of the experiment. Using cosmic muons, it is …
-
Development of a high magnetic field drift chamber for the chaos spectrometer
… inconsistent requirements for the inner (WC3) drift chamber. This detector chamber has to be cylindrical, of low mass, have excellent spatial resolution (<200 µm) and operate in a variable magnetic field of up to 1.6 T. This thesis describes the investigations which culminated in the testing of …
-
A study of background radiation distributions for the SLAC B factory drift chamber
… bremsstrahlung background radiation in the BABAR Drift Chamber at the Stanford Linear Accelerator Center (SLAC) has been modeled. Simulations show that occupancies are well within manageable levels (peaked at 0.55% in the inner layers) at nominal rates and that radical changes in the endplate …
-
Construction of an ultra-thin cylindrical drift chamber for measurement of the rare decay K+ [formula]
… a modified detector. The ultra-thin cylindrical drift-chamber with helical cathode strips for measurement of the axial coordinate of the charged particle track is described. A design for charge pre-amplifiers to instrument the cathode strips is discussed. The desired gain was achieved for single …
-
Search for a light Higgs boson with the BABAR detector : with proposals to improve drift chamber aging studies and particle identification
… Standard Model. Proposals to improve drift chamber aging studies and particle identification are included as part of the thesis. We propose to improve aging studies with prototypes that better resemble a full-scale drift chamber. Using TRIUMF beam data, we establish that at a particle …
-
Modular multi-wire drift chambers for the TRIUMF QQD-spectrometer
A modular, multiwire drift chamber was built and tested in the M13 area. The resolution obtained with six sense wires, was in the horizontal drift direction σ(mean) < (79.9± .2)µm, with an angular resolution of (9.37±.02)mrads. With the drift chamber mounted in the first wire chamber position of …
-
NUCLEAR FRAGMENTATION CROSS SECTIONS MEASUREMENTS FOR HADRONTHERAPY: IMPLEMENTATION AND OPTIMIZATION OF A BEAM MONITORING SYSTEM
… experimental setups and in both of them a drift chamber is adopted as Beam Monitor to measure the projectile direction and position, to count the total number of delivered particles and to reject the pre-target fragmentation events. In this Ph. D. project, which has contributed to the …
-
An inner wire chamber for the measurement of K+ Pi+vv
A thin cylindrical drift chamber with helical cathode strips for measuring the z coordinate of charged particle tracks is described. The motivations for adding the chamber to the existing detector of Brookhaven experiment E787 are discussed. The results of a Monte Carlo study of the momentum …
-
Efficient physics signal selectors for the first trigger level of the Belle II experiment based on machine learning
… SuperKEKB in Tsukuba, Japan. Using the hit and drift time information from the central drift chamber, a pool of expert neural networks estimates the 3D track parameters of the single tracks found by a 2D Hough finder. The neural networks are already implemented on parallel FPGA hardware for real …
-
Experimental study of cham quark fragmentation
… mass energy of 29 GeV using the time-projection-chamber (TPC) detector at the SLAC storage ring PEP. The polarization of the D[superscript]* +, the energy dependency of the polarization, and the spin density matrix of D[superscript]* + are measured. In 147pb[superscript]-1 of data we see no …
-
Analysing power of inclusively produced pions using high energy polarized protons
… which may have passed through the edges of drift chamber frames. Minimal cuts are applied to the data, requiring that the pions come from the target and pass through the drift chamber active areas. The acceptance of the apparatus was verified by Monte Carlo calculation. The measured vertical …
-
Spin polarization of J/Ψ through lepton decay
… arm. The PHENIX detector systems, namely the drift chamber, electromagnetic calorimeter, and RICH, are used to identify electrons. To examine the quality of the polarization fit, χ2 methods are used to scrutinize the simulated data.</p> <p>The bremsstrahlung research shows that there is a …
-
A proton polarimeter for pion physics at TRIUMF
… polarimeter employing multi-wire delay-line drift chambers (MWDDCs) has been built for ongoing pion absorption studies in the meson area at TRIUMF. A brief introduction of the theoretical basis of polarimeter and MWDCC operation is offered. An in-depth study of our own system is presented …
-
Design and optimization of 6li neutron-capture pulse mode ion chamber
… inexpensive 6Li neutron-capture pulse-mode ion chamber (LiPMIC) for neutron detection that overcomes the fill-gas contamination stemming from outgas of detector components. This research also provides a demonstration of performance of LiPMICs. Simulations performed with GARFIELD, a drift-chamber …
-
Cluster counting in drift chambers for particle identification and tracking
Drift chambers are a type of gaseous ionization detector used in high-energy physics experiments. They can identify charged particles and measure their momentum. When a high-energy charged particle crosses the drift chamber, it ionizes the gas. The liberated electrons drift towards …
Page 1 of 2