Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 61 for “"Drift Tube"”.

  1. Flowing atmospheric pressure afterglow drift tube ion mobility spectrometry evidence discrimination

    Drift Tube Ion Mobility Spectrometry (DTIMS) is a gas-phase analytical separation method allows separation of chemical compounds based on the individual mobilities as they travel through a uniform electric field and collide with neutral gas molecules. DTIMS features advantages including excellent …

    ttu Repository record for Flowing atmospheric pressure afterglow drift tube ion mobility spectrometry evidence discrimination (opens in a new tab)

  2. CONSTRUCTION AND APPLICATION OF A DRIFT TUBE MASS SPECTROMETER FOR EXPERIMENTAL ION STUDIES

    A drift tube mass spectometer suitable for experimental ion studies was constructed. It contains the following features which yield improved performance over previous devices. The drift tube pressure is continually monitored and regulated by a control system which utilizes a servo-controlled valve …

    nus Repository record for CONSTRUCTION AND APPLICATION OF A DRIFT TUBE MASS SPECTROMETER FOR EXPERIMENTAL ION STUDIES (opens in a new tab) Download file for CONSTRUCTION AND APPLICATION OF A DRIFT TUBE MASS SPECTROMETER FOR EXPERIMENTAL ION STUDIES (opens in a new tab)

  3. Drift Tube Ion Mobility Measurements for Thermochemistry, Kinetics and Polymerization of Cluster Ions

    In this work, the Drift Tube Ion Mobility technique is used to study the hydrophobic hydration and solvation of organic ions and measure the thermochemistry and kinetics of ion-molecule reactions. Furthermore, an exploratory study of the intracluster polymerization of isoprene will be presented and …

    vcu Repository record for Drift Tube Ion Mobility Measurements for Thermochemistry, Kinetics and Polymerization of Cluster Ions (opens in a new tab)

  4. Advancements in coupling ambient plasma ionization and drift tube ion mobility spectrometry with mass spectrometry

    … glow discharge source paired with a standalone drift tube ion mobility detector. Additionally, a miniaturized microplasma device intended for portability and low-resource operation in remote environmental monitoring applications is reported. The final research efforts were directed toward …

    gatech Repository record for Advancements in coupling ambient plasma ionization and drift tube ion mobility spectrometry with mass spectrometry (opens in a new tab)

  5. Modeling and experimenting a novel inverted drift tube device for improved mobility analysis of aerosol particles

    … than that of the currently available DTIMS (Drift Tube Ion Mobility Spectrometry) instruments. The unique feature of this instrument is the diffusion auto-correction. Being tunable, It can separate the wide range of particles of different diameters. The working principle of this new IMS …

    iupui Repository record for Modeling and experimenting a novel inverted drift tube device for improved mobility analysis of aerosol particles (opens in a new tab)

  6. Ageing studies for the ATLAS MDT Muonchambers and development of a gas filter to prevent drift tube ageing

    … spectrometer of the ATLAS detector at CERN uses drift tubes as basic detection elements over most of the solid angle. The performance of these monitored drift tubes (MDTs), in particular their spatial resolution of 80 µm, determines the precision of the spectrometer. If ageing effects occur, the …

    freiburg-diss Repository record for Ageing studies for the ATLAS MDT Muonchambers and development of a gas filter to prevent drift tube ageing (opens in a new tab)

  7. STUDIES OF TRANSVERSE DIFFUSION OF ALKALI IONS IN NOBLE GASES

    A new drift-tube apparatus has been developed for measuring DT/K, the ratio of the transverse diffusion coefficient to the mobility of ions in a neutral gas under the influence of an electric field. The main features are the ion current detector, which comprises 65 parallel rods, and an external …

    nus Repository record for STUDIES OF TRANSVERSE DIFFUSION OF ALKALI IONS IN NOBLE GASES (opens in a new tab) Download file for STUDIES OF TRANSVERSE DIFFUSION OF ALKALI IONS IN NOBLE GASES (opens in a new tab)

  8. Experiments Conducted on the Electron Beam Produced by a Dense Plasma Focus

    … magnetic field was introduced into the beam drift region so as to reduce beam loss due to contact with the conductive walls of the drift tube. The beam guiding apparatus was shown to increase the probability of observing a beam with a peak current greater than 10 kA from 10% of the DPF …

    odu Repository record for Experiments Conducted on the Electron Beam Produced by a Dense Plasma Focus (opens in a new tab)

  9. Improving the Sensitivity and Resolution of Miniature Ion Mobility Spectrometers with a Capacitive Trans Impedance Amplifier

    … explosives. Next, Sandia provided miniature IMS drift tubes, but incompatibilities necessitated the design of new miniature systems. At first, only the drift tube itself was redesigned, but eventually a complete miniature IMS, including the ionizer, circuitry, and read out, was designed and …

    arizona-thes Repository record for Improving the Sensitivity and Resolution of Miniature Ion Mobility Spectrometers with a Capacitive Trans Impedance Amplifier (opens in a new tab)

  10. Calibration, optimization, and deployment of PTR-MS instruments during the AIRMAP project

    … the ion chemistry that occurs within the PTR-MS drift tube reaction chamber. The PTR-MS uses a differentially pumped skimmer to prevent excess water from the ion source from entering the drift tube reaction chamber. By placing a metering valve in between the skimmer region and the pump, it was …

    unh-thes Repository record for Calibration, optimization, and deployment of PTR-MS instruments during the AIRMAP project (opens in a new tab)

  11. Advancements in characterizing protein structures and dynamics through innovative mass spectrometry instrumentation

    … A custom atmospheric pressure ion mobility drift tube was optimized to interface with a commercial high resolution Orbitrap mass spectrometer for enhanced protein conformational analysis. In addition, a low pressure one-meter-long drift tube was built to improve the ion transmission and …

    texas Repository record for Advancements in characterizing protein structures and dynamics through innovative mass spectrometry instrumentation (opens in a new tab)

  12. Extending the frontiers of mass spectrometric instrumentation and methods

    … protein ion heating between the ion trap and drift tube is described. Besides the novel instrument, mass spectrometric methods were developed for the rapid analysis of coal using direct analysis in real time.</p>

    iastate Repository record for Extending the frontiers of mass spectrometric instrumentation and methods (opens in a new tab)

  13. Electron Ionization and Excitation Coefficients for Argon, Krypton, and Xenon in the Low E/p Region and Kinetics of Interhalogen Diatomics

    … in the low E/p region (1-12 V/cm torr) using a drift-tube apparatus. Discrepancies between previous measurements have been resolved and shown to be due to photoelectric emission attributed to the rare gas metastables. Using this information a revised set of self-consistent near threshold …

    uiuc Repository record for Electron Ionization and Excitation Coefficients for Argon, Krypton, and Xenon in the Low E/p Region and Kinetics of Interhalogen Diatomics (opens in a new tab)

  14. The application of ion mobility mass spectrometry to molecules of pharmaceutical significance

    … experiments have been conducted to measure the drift-time and calculate collision cross-sections (CCSs) using travelling wave ion mobility spectrometry, and determine the CCS using drift-tube ion mobility spectrometry systems of analytes. The aim of the study was to identify if predictive …

    greenwich Download PDF for The application of ion mobility mass spectrometry to molecules of pharmaceutical significance (opens in a new tab)

  15. Vertical compact torus injection into the STOR-M Tokamak

    … modified by attaching a segment of 90° curved drift tube to bend the CT trajectory from horizontal to vertical. Bench tests have shown that a CT injected horizontally can be deflected effectively to the vertical direction. The velocity of 130 kmsˉ¹ has been achieved while the CT passes through …

    sask Repository record for Vertical compact torus injection into the STOR-M Tokamak (opens in a new tab)

  16. Conservation of charge in secondary electron emission test stand

    … directs the primary electron beam through a beam drift tube piercing the center of a particle position detector with controlling grid towards the sample under test. Secondary electrons emitted by the sample either drift freely or are drawn by a grid potential to the particle position detector. The …

    unlv Repository record for Conservation of charge in secondary electron emission test stand (opens in a new tab) Download PDF for Conservation of charge in secondary electron emission test stand (opens in a new tab)

  17. Studies of the ATLAS Muon spectrometer with testbeam and simulated physics data

    … of the Muon Spectrometer is the Monitored Drift Tube chamber. The reconstruction potential of a BIS type Monitored Drift Tube chamber, in a special setup at the H8 Testbeam experimental area at CERN, is investigated. Data from the BIS muon chamber with both muon and positron beams are taken …

    greece Repository record for Studies of the ATLAS Muon spectrometer with testbeam and simulated physics data (opens in a new tab)

Page 1 of 4