Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 13 of 13 for “"Drift chambers"”.
-
Drift chambers for KTeV
… for reliable operation of the four large drift chambers for KTeV. In time, the problem with the loss of sense wires will be solved. These chambers will have a resolution of 100 microns per plane and play a major role in measuring the direct CP violation parameter …
-
Cluster counting in drift chambers for particle identification and tracking
Drift chambers are a type of gaseous ionization detector used in high-energy physics experiments. They can identify charged particles and measure their momentum. When a high-energy charged particle crosses the drift chamber, it ionizes the gas. The liberated electrons drift towards …
-
Modular multi-wire drift chambers for the TRIUMF QQD-spectrometer
A modular, multiwire drift chamber was built and tested in the M13 area. The resolution obtained with six sense wires, was in the horizontal drift direction σ(mean) < (79.9± .2)µm, with an angular resolution of (9.37±.02)mrads. With the drift chamber mounted in the first wire chamber position of …
-
A study of the operational characteristics of large drift chambers used in a particle spectrometer
Thesis (M.S.)--Michigan State University. Department of Physics, 1981
-
A proton polarimeter for pion physics at TRIUMF
… polarimeter employing multi-wire delay-line drift chambers (MWDDCs) has been built for ongoing pion absorption studies in the meson area at TRIUMF. A brief introduction of the theoretical basis of polarimeter and MWDCC operation is offered. An in-depth study of our own system is presented …
-
The first direct measurement of the weak charge of the proton
… commissioning, and use of the vertical drift chambers (VDC) used in the Qweak experiment to measure the scattered electron's profile and the momentum transfer (Q 2) of the ep scattering. The Q 2 was measured to be 0.0274 +/- 0.0013 GeV2/c 2 and QPweak was measured to be 0.102 +/- 0.036, …
-
Search for the Higgs Boson in H->WW Decays at the D0 Experiment and Precise Muon Tracking
… (LHC). An alignment system for ATLAS muon drift chambers at the cosmic ray measurement facility at LMU Munich is presented.
-
Laser Ionisation Studies - Applications in Nuclear Waste Monitoring
… laser system and caesium detection/ detection chambers are described in detail. The study of background ionisation in proportional counter systems similar to that used for caesium comprises Chapter four. The significance of this work is that non-resonant background ionisation arising in …
-
Detection of Stable Isotopes Using Resonance Ionisation Spectroscopy
… impurities in counter gases used in multiwire drift chambers at CERN. After completion of this high energy physics application, the technique was then directed towards the development of a combination of resonance ionisation with mass spectrometry (RIMS) for the purpose of ultra sensitive trace …
-
The multi-term Boltzmann equation analysis and Monte Carlo study of hydrodynamic and non-hydrodynamic charged particle swarms
… to plasma processing, gas laser discharges and drift chambers for detection particles in mind. Two complimentary techniques are developed: A time-dependent true multi-term solution of Boltzmann’s equation and a Monte Carlo simulation technique, both adapted to consider both time-dependent …