Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 12 of 12 for “"Drift limit"”.

  1. Performance Prediction and Evaluation of Low Ductility Steel Moment Frames for Seismic Loads

    … in SDC D which exceeded the permanent residual drift limit. As was seen from the measured moment-rotation behavior of the connection, the end-plate connection behaves very similar to the fully restrained connections. Therefore, the connection is expected to perform very well based on the SMF …

    uiuc Repository record for Performance Prediction and Evaluation of Low Ductility Steel Moment Frames for Seismic Loads (opens in a new tab)

  2. An Integrated Circuit Analog Computer

    … 1000. The low amplifier gain, and amplifier drift limit the accuracy of the solution. Results obtained are sometimes confusing. Many integrated circuit operational amplifiers available on the market seem to give much better performance, priced from a few dollars in monolithic form up to …

    sdstate Repository record for An Integrated Circuit Analog Computer (opens in a new tab)

  3. Effects of Vertical Ground Motion on Seismic Performance of Reinforced Concrete Flat-Plate Buildings

    … of vertical ground motion increases lateral drift of the building by less than 3% when compared with applying ground motions in the horizontal directions. However, the vertical ground motion can significantly increase the slab deformation localized at the columns on average by as much as 30% …

    unlv Repository record for Effects of Vertical Ground Motion on Seismic Performance of Reinforced Concrete Flat-Plate Buildings (opens in a new tab) Download PDF for Effects of Vertical Ground Motion on Seismic Performance of Reinforced Concrete Flat-Plate Buildings (opens in a new tab)

  4. Modelling of the seismic performance of connections and walls in ancient masonry buildings

    … in the wall response was evaluated. The drift capacity of the walls numerically analysed was compared with the drift limits imposed by codes showing that drift limit recommended in codes for shear is not accomplished for all the walls. For this reason, some walls were analysed considering …

    minho-thes Repository record for Modelling of the seismic performance of connections and walls in ancient masonry buildings (opens in a new tab)

  5. Placement of fluid viscous dampers to reduce total-building seismic damage

    … viscous dampers (FVDs) can improve interstorey drifts and floor accelerations, parameters which characterise seismic demands. The distribution of dampers within a building and the amount of supplemental damping are critical decisions. Many placement methods have been proposed, however no …

    oxford Repository record for Placement of fluid viscous dampers to reduce total-building seismic damage (opens in a new tab)

  6. Assessment of confinement models for reinforced concrete columns subjected to seismic loading

    … requirements of each model with the lateral drift observed for each column within the database. The plot showed the drift ratio achieved by the column test versus a ratio of lateral steel Ash provided over that which is required by ACI (Ash provided / Ash ACI)- A drift ratio of 2.5% was …

    ubc Repository record for Assessment of confinement models for reinforced concrete columns subjected to seismic loading (opens in a new tab) Download PDF for Assessment of confinement models for reinforced concrete columns subjected to seismic loading (opens in a new tab)

  7. Seismic Retrofitting of Low-Rise Reinforced Concrete (RC) Structures: a Multi-Faceted Evaluation

    … However, Haiti remains a country with limited knowledge about the vulnerability of RC buildings to seismic events and retrofitting solutions. This study aims to address this knowledge gap by conducting a comprehensive analysis of Haitian RC structures and evaluating multiple retrofit …

    rice Repository record for Seismic Retrofitting of Low-Rise Reinforced Concrete (RC) Structures: a Multi-Faceted Evaluation (opens in a new tab)

  8. Effect of Viscous Fluid Dampers on Steel Moment Frame Designed for Strength and Hybrid Steel Moment Frame Design

    … moment frames are almost always controlled by drift, it was thought that two different moment frames, controlled by strength or controlled by drift (stiffness), could be designed in Seattle and the effect of additional dampers on the structural behavior of the strength controlled design could …

    vt Repository record for Effect of Viscous Fluid Dampers on Steel Moment Frame Designed for Strength and Hybrid Steel Moment Frame Design (opens in a new tab)

  9. Development Of Wind Performance Curves For Seismically Damaged Structures

    Recently, there has been an immense increase in the severity and the frequency of extreme events across the globe. Accordingly, there is a demand for tools that can provide immediate assessment for structures safety after extreme events. This thesis introduces performance curves of wind events for …

    uab Repository record for Development Of Wind Performance Curves For Seismically Damaged Structures (opens in a new tab)

  10. Simplified Seismic Design for Mid-Rise Buildings with Vertical Combination of Framing Systems

    … mass distribution and specified storey drift limit. In addition, by considering both the mass and stiffness irregularities, two manually-based simplified methods, i.e., modified equivalent lateral force procedure (ELF) and two-stage analysis procedures, are proposed to evaluate seismic …

    waterloo Repository record for Simplified Seismic Design for Mid-Rise Buildings with Vertical Combination of Framing Systems (opens in a new tab)

  11. In-Plane Lateral Load Capacities of Vertically Oriented Interlocking Timber Panels

    The Vertically Oriented Interlocking Timber (VOIT) panel is a new solid wood panel similar to Interlocking Cross Laminated Timber (ICLT) and the more commonly known Cross Laminated Timber (CLT). Like ICLT, VOIT panels use timber connections instead of the adhesives or metal fasteners common to CLT. …

    byu Repository record for In-Plane Lateral Load Capacities of Vertically Oriented Interlocking Timber Panels (opens in a new tab) Download PDF for In-Plane Lateral Load Capacities of Vertically Oriented Interlocking Timber Panels (opens in a new tab)